SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Park Sun Young) "

Sökning: WFRF:(Park Sun Young)

  • Resultat 1-10 av 328
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Adare, A., et al. (författare)
  • Measurements of Elliptic and Triangular Flow in High-Multiplicity He-3 + Au Collisions at root s(NN)=200 GeV
  • 2015
  • Ingår i: Physical Review Letters. - 1079-7114. ; 115:14
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the first measurement of elliptic (v(2)) and triangular (v(3)) flow in high-multiplicity He-3 + Au collisions at root s(NN) = 200 GeV. Two-particle correlations, where the particles have a large separation in pseudorapidity, are compared in He-3 + Au and in p + p collisions and indicate that collective effects dominate the second and third Fourier components for the correlations observed in the He-3 + Au system. The collective behavior is quantified in terms of elliptic v(2) and triangular v(3) anisotropy coefficients measured with respect to their corresponding event planes. The v(2) values are comparable to those previously measured in d + Au collisions at the same nucleon-nucleon center-of-mass energy. Comparisons with various theoretical predictions are made, including to models where the hot spots created by the impact of the three He-3 nucleons on the Au nucleus expand hydrodynamically to generate the triangular flow. The agreement of these models with data may indicate the formation of low-viscosity quark-gluon plasma even in these small collision systems.
  •  
3.
  • Beal, Jacob, et al. (författare)
  • Robust estimation of bacterial cell count from optical density
  • 2020
  • Ingår i: Communications Biology. - : Springer Science and Business Media LLC. - 2399-3642. ; 3:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data.
  •  
4.
  • Klionsky, Daniel J., et al. (författare)
  • Guidelines for the use and interpretation of assays for monitoring autophagy
  • 2012
  • Ingår i: Autophagy. - : Informa UK Limited. - 1554-8635 .- 1554-8627. ; 8:4, s. 445-544
  • Forskningsöversikt (refereegranskat)abstract
    • In 2008 we published the first set of guidelines for standardizing research in autophagy. Since then, research on this topic has continued to accelerate, and many new scientists have entered the field. Our knowledge base and relevant new technologies have also been expanding. Accordingly, it is important to update these guidelines for monitoring autophagy in different organisms. Various reviews have described the range of assays that have been used for this purpose. Nevertheless, there continues to be confusion regarding acceptable methods to measure autophagy, especially in multicellular eukaryotes. A key point that needs to be emphasized is that there is a difference between measurements that monitor the numbers or volume of autophagic elements (e.g., autophagosomes or autolysosomes) at any stage of the autophagic process vs. those that measure flux through the autophagy pathway (i.e., the complete process); thus, a block in macroautophagy that results in autophagosome accumulation needs to be differentiated from stimuli that result in increased autophagic activity, defined as increased autophagy induction coupled with increased delivery to, and degradation within, lysosomes (in most higher eukaryotes and some protists such as Dictyostelium) or the vacuole (in plants and fungi). In other words, it is especially important that investigators new to the field understand that the appearance of more autophagosomes does not necessarily equate with more autophagy. In fact, in many cases, autophagosomes accumulate because of a block in trafficking to lysosomes without a concomitant change in autophagosome biogenesis, whereas an increase in autolysosomes may reflect a reduction in degradative activity. Here, we present a set of guidelines for the selection and interpretation of methods for use by investigators who aim to examine macroautophagy and related processes, as well as for reviewers who need to provide realistic and reasonable critiques of papers that are focused on these processes. These guidelines are not meant to be a formulaic set of rules, because the appropriate assays depend in part on the question being asked and the system being used. In addition, we emphasize that no individual assay is guaranteed to be the most appropriate one in every situation, and we strongly recommend the use of multiple assays to monitor autophagy. In these guidelines, we consider these various methods of assessing autophagy and what information can, or cannot, be obtained from them. Finally, by discussing the merits and limits of particular autophagy assays, we hope to encourage technical innovation in the field.
  •  
5.
  • Aad, G, et al. (författare)
  • 2015
  • swepub:Mat__t
  •  
6.
  • 2019
  • Tidskriftsartikel (refereegranskat)
  •  
7.
  • Adare, A., et al. (författare)
  • Measurement of higher cumulants of net-charge multiplicity distributions in Au plus Au collisions at root s(NN)=7.7-200 GeV
  • 2016
  • Ingår i: Physical Review C (Nuclear Physics). - 0556-2813. ; 93:1
  • Tidskriftsartikel (refereegranskat)abstract
    • We report the measurement of cumulants (C-n,n = 1, ..., 4) of the net-charge distributions measured within pseudorapidity (vertical bar eta vertical bar < 0.35) in Au + Au collisions at root s(NN) = 7.7-200 GeV with the PHENIX experiment at the Relativistic Heavy Ion Collider. The ratios of cumulants (e.g., C-1/C-2, C-3/C-1) of the net-charge distributions, which can be related to volume independent susceptibility ratios, are studied as a function of centrality and energy. These quantities are important to understand the quantum-chromodynamics phase diagram and possible existence of a critical end point. The measured values are very well described by expectation from negative binomial distributions. We do not observe any nonmonotonic behavior in the ratios of the cumulants as a function of collision energy. The measured values of C-1/C-2 and C-3/C-1 can be directly compared to lattice quantum-chromodynamics calculations and thus allow extraction of both the chemical freeze-out temperature and the baryon chemical potential at each center-of-mass energy. The extracted baryon chemical potentials are in excellent agreement with a thermal-statistical analysis model.
  •  
8.
  • Adare, A., et al. (författare)
  • Search for dark photons from neutral meson decays in p plus p and d plus Au collisions at root s(NN)=200 GeV
  • 2015
  • Ingår i: Physical Review C (Nuclear Physics). - 0556-2813. ; 91:3
  • Tidskriftsartikel (refereegranskat)abstract
    • The standard model (SM) of particle physics is spectacularly successful, yet the measured value of the muon anomalous magnetic moment (g - 2)mu deviates from SM calculations by 3.6 sigma. Several theoretical models attribute this to the existence of a "dark photon," an additional U(1) gauge boson, which is weakly coupled to ordinary photons. The PHENIX experiment at the Relativistic Heavy Ion Collider has searched for a dark photon, U, in pi(0), eta -> gamma e(+)e(-) decays and obtained upper limits of O(2 x 10(-6)) on U-gamma mixing at 90% C.L. for the mass range 30 < m(U) < 90 MeV/c(2). Combined with other experimental limits, the remaining region in the U-gamma mixing parameter space that can explain the (g - 2)(mu) deviation from its SM value is nearly completely excluded at the 90% confidence level, with only a small region of 29 < m(U) < 32 MeV/c(2) remaining.
  •  
9.
  • Adare, A., et al. (författare)
  • Systematic study of charged-pion and kaon femtoscopy in Au plus Au collisions at root s(NN)=200 GeV
  • 2015
  • Ingår i: Physical Review C (Nuclear Physics). - 0556-2813. ; 92:3
  • Tidskriftsartikel (refereegranskat)abstract
    • We present a systematic study of charged-pion and kaon interferometry in Au + Au collisions at root s(NN) = 200 GeV. The kaon mean source radii are found to be larger than pion radii in the outward and longitudinal directions for the same transverse mass; this difference increases for more central collisions. The azimuthal-angle dependence of the radii was measured with respect to the second-order event plane and similar oscillations of the source radii were found for pions and kaons. Hydrodynamic models qualitatively describe the similar oscillations of the mean source radii for pions and kaons, but they do not fully describe the transverse-mass dependence of the oscillations.
  •  
10.
  • Niemi, MEK, et al. (författare)
  • 2021
  • swepub:Mat__t
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 328
Typ av publikation
tidskriftsartikel (193)
forskningsöversikt (4)
konferensbidrag (1)
Typ av innehåll
refereegranskat (318)
Författare/redaktör
Hill, J. C. (277)
Angerami, A. (272)
Ellinghaus, F. (269)
Lenzi, B. (268)
Kim, S. H. (267)
Gallus, P. (263)
visa fler...
Hughes, G. (262)
Hasegawa, S. (261)
Clark, A. (260)
Donadelli, M. (260)
Esposito, B. (260)
Fox, H. (260)
Hasegawa, Y. (260)
Meyer, J. (260)
Adye, T. (259)
Arai, Y. (259)
Backes, M. (259)
Barklow, T. (259)
Bella, G. (259)
Benekos, N. (259)
Campana, S. (259)
Chen, H. (259)
Chen, X. (259)
Cranmer, K. (259)
Davies, M. (259)
Deluca, C. (259)
Eigen, G. (259)
Etzion, E. (259)
Ferrari, P. (259)
Ferrer, A. (259)
Fleck, I. (259)
Garcia, C. (259)
George, S. (259)
Gross, E. (259)
Herten, G. (259)
Hirose, M. (259)
Jinnouchi, O. (259)
Kado, M. (259)
Kawagoe, K. (259)
Kim, H. (259)
Kluth, S. (259)
Kobayashi, T. (259)
Leroy, C. (259)
Liebig, W. (259)
Lohse, T. (259)
Lucotte, A. (259)
Maeno, T. (259)
Martin, B. (259)
Martinez, M. (259)
Masik, J. (259)
visa färre...
Lärosäte
Lunds universitet (147)
Uppsala universitet (123)
Kungliga Tekniska Högskolan (121)
Stockholms universitet (118)
Chalmers tekniska högskola (28)
Karolinska Institutet (8)
visa fler...
Göteborgs universitet (3)
Umeå universitet (3)
Linköpings universitet (3)
Sveriges Lantbruksuniversitet (2)
Högskolan i Halmstad (1)
Malmö universitet (1)
Linnéuniversitetet (1)
VTI - Statens väg- och transportforskningsinstitut (1)
visa färre...
Språk
Engelska (328)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (172)
Medicin och hälsovetenskap (14)
Teknik (6)
Samhällsvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy