SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Parsonage William) "

Sökning: WFRF:(Parsonage William)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Nestelberger, Thomas, et al. (författare)
  • Diagnosis of acute myocardial infarction in the presence of left bundle branch block
  • 2019
  • Ingår i: Heart. - : BMJ PUBLISHING GROUP. - 1355-6037 .- 1468-201X. ; 105:20, s. 1559-1567
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: Patients with suspected acute myocardial infarction (AMI) in the setting of left bundle branch block (LBBB) present an important diagnostic and therapeutic challenge to the clinician.Methods: We prospectively evaluated the incidence of AMI and diagnostic performance of specific ECG and high-sensitivity cardiac troponin (hs-cTn) criteria in patients presenting with chest discomfort to 26 emergency departments in three international, prospective, diagnostic studies. The final diagnosis of AMI was centrally adjudicated by two independent cardiologists according to the universal definition of myocardial infarction.Results: Among 8830 patients, LBBB was present in 247 (2.8%). AMI was the final diagnosis in 30% of patients with LBBB, with similar incidence in those with known LBBB versus those with presumably new LBBB (29% vs 35%, p=0.42). ECG criteria had low sensitivity (1%-12%) but high specificity (95%-100%) for AMI. The diagnostic accuracy as quantified by the receiver operating characteristics (ROC) curve of hs-cTnT and hs-cTnI concentrations at presentation (area under the ROC curve (AUC) 0.91, 95%CI 0.85 to 0.96 and AUC 0.89, 95%CI 0.83 to 0.95), as well as that of their 0/1-hour and 0/2-hour changes, was very high. A diagnostic algorithm combining ECG criteria with hs-cTnT/I concentrations and their absolute changes at 1hour or 2hours derived in cohort 1 (45 of 45(100%) patients with AMI correctly identified) showed high efficacy and accuracy when externally validated in cohorts 2 and 3 (28 of 29 patients, 97%).Conclusion: Most patients presenting with suspected AMI and LBBB will be found to have diagnoses other than AMI. Combining ECG criteria with hs-cTnT/I testing at 0/1 hour or 0/2hours allows early and accurate diagnosis of AMI in LBBB.
  •  
2.
  • Eggers, Kai M., 1962-, et al. (författare)
  • Diagnostic and prognostic performance of the ratio between high-sensitivity cardiac troponin I and troponin T in patients with chest pain
  • 2022
  • Ingår i: PLOS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 17:11
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Elevations of high-sensitivity cardiac troponin (hs-cTn) concentrations not related to type 1 myocardial infarction are common in chest pain patients presenting to emergency departments. The discrimination of these patients from those with type 1 myocardial infarction (MI) is challenging and resource-consuming. We aimed to investigate whether the hs-cTn I/T ratio might provide diagnostic and prognostic increment in this context.Methods We calculated the hs-cTn I/T ratio in 888 chest pain patients having hs-cTnI (Abbott Laboratories) or hs-cTnT (Roche Diagnostics) concentrations above the respective 99(th) percentile at 2 hours from presentation. All patients were followed for one year regarding mortality.Results The median hs-cTn I/T ratio was 3.45 (25(th), 75(th) percentiles 1.80-6.59) in type 1 MI patients (n = 408 (sic) 46.0%]), 1.18 (0.81-1.90) in type 2 MI patients (n = 56 (sic) 6.3%]) and 0.67 (0.39-1.12) in patients without MI. The hs-cTn I/T ratio provided good discrimination of type 1 MI from no type 1 MI (area under the receiver-operator characteristic curve 0.89 (sic) 95% confidence interval 0.86-0.91]), of type 1 MI from type 2 MI (area under the curve 0.81 (sic) 95% confidence interval 0.74-0.87]), and was associated with type 1 MI in adjusted analyses. The hs-cTn I/T ratio provided no consistent prognostic value.Conclusions The hs-cTn I/T ratio appears to be useful for early diagnosis of type 1 MI and its discrimination from type 2 MI in chest pain patients presenting with elevated hs-cTn. Differences in hs-cTn I/T ratio values may reflect variations in hs-cTn release mechanisms in response to different types of myocardial injury.
  •  
3.
  • Eggers, Kai M., 1962-, et al. (författare)
  • Diagnostic and prognostic performance of the ratio between high-sensitivity cardiac troponin I and troponin T in patients with chest pain.
  • 2022
  • Ingår i: PloS one. - : Public Library of Science (PLoS). - 1932-6203. ; 17:11
  • Tidskriftsartikel (refereegranskat)abstract
    • Elevations of high-sensitivity cardiac troponin (hs-cTn) concentrations not related to type 1 myocardial infarction are common in chest pain patients presenting to emergency departments. The discrimination of these patients from those with type 1 myocardial infarction (MI) is challenging and resource-consuming. We aimed to investigate whether the hs-cTn I/T ratio might provide diagnostic and prognostic increment in this context.We calculated the hs-cTn I/T ratio in 888 chest pain patients having hs-cTnI (Abbott Laboratories) or hs-cTnT (Roche Diagnostics) concentrations above the respective 99th percentile at 2 hours from presentation. All patients were followed for one year regarding mortality.The median hs-cTn I/T ratio was 3.45 (25th, 75th percentiles 1.80-6.59) in type 1 MI patients (n = 408 ☯46.0%]), 1.18 (0.81-1.90) in type 2 MI patients (n = 56 ☯6.3%]) and 0.67 (0.39-1.12) in patients without MI. The hs-cTn I/T ratio provided good discrimination of type 1 MI from no type 1 MI (area under the receiver-operator characteristic curve 0.89 ☯95% confidence interval 0.86-0.91]), of type 1 MI from type 2 MI (area under the curve 0.81 ☯95% confidence interval 0.74-0.87]), and was associated with type 1 MI in adjusted analyses. The hs-cTn I/T ratio provided no consistent prognostic value.The hs-cTn I/T ratio appears to be useful for early diagnosis of type 1 MI and its discrimination from type 2 MI in chest pain patients presenting with elevated hs-cTn. Differences in hs-cTn I/T ratio values may reflect variations in hs-cTn release mechanisms in response to different types of myocardial injury.
  •  
4.
  • Eggers, Kai M., et al. (författare)
  • Two-hour diagnostic algorithms for early assessment of patients with acute chest pain - Implications of lowering the cardiac troponin I cut-off to the 97.5th percentile
  • 2015
  • Ingår i: Clinica Chimica Acta. - : Elsevier BV. - 0009-8981 .- 1873-3492. ; 445, s. 19-24
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: Assessment of patients with suspected non-ST elevation myocardial infarction (NSTEMI) is based on cardiac troponin (cTn) levels with the 99th percentile as cut-off. However, cardiovascular risk starts already at lower troponin concentrations. We therefore, aimed to investigate the utility of 2-hour algorithms using the high-sensitivity cardiac troponin I (hs-cTnI) 97.5th percentile as cut-off which corresponds to the standard URL for most biomarkers. Methods: Hs-cTnI was measured at presentation and 2 h in 1624 chest pain patients. Diagnostic algorithms were developed applying hs-cTnI levels dichotomized at the 99th and 97.5th percentiles combined with hs-cTnI changes and/or ECG findings. Results: The prevalence of NSTEMI was 13.9%. The adjusted odds ratios for 1-year mortality were 2.7(95% CI 1.4-5.1) for the 99th percentile and 3.1 (95% CI 1.6-5.9) for the 97.5th percentile. The best-performing 99th percentile-based algorithms provided a positive predictive value (PPV) of 863% and a negative predictive value (NPV) of 993%. Using 97.5th percentile-based algorithms to define NSTEMI resulted in few reclassifications and yielded similar diagnostic estimates (PPV 85.4%, NPV 99.4%). Conclusion: The hs-cTnI 97.5th percentile integrated into 2-hour algorithms provided high diagnostic estimates and could, due to better prognostic properties serve as an alternative to the 99th percentile.
  •  
5.
  • Neumann, Johannes Tobias, et al. (författare)
  • Personalized diagnosis in suspected myocardial infarction
  • 2023
  • Ingår i: Clinical Research in Cardiology. - : Springer. - 1861-0684 .- 1861-0692. ; 112, s. 1288-1301
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: In suspected myocardial infarction (MI), guidelines recommend using high-sensitivity cardiac troponin (hscTn)- based approaches. These require fixed assay-specific thresholds and timepoints, without directly integrating clinical information. Using machine-learning techniques including hs-cTn and clinical routine variables, we aimed to build a digital tool to directly estimate the individual probability of MI, allowing for numerous hs-cTn assays.Methods: In 2,575 patients presenting to the emergency department with suspected MI, two ensembles of machine-learning models using single or serial concentrations of six different hs-cTn assays were derived to estimate the individual MI probability ( ARTEMIS model). Discriminative performance of the models was assessed using area under the receiver operating characteristic curve (AUC) and logLoss. Model performance was validated in an external cohort with 1688 patients and tested for global generalizability in 13 international cohorts with 23,411 patients.Results: Eleven routinely available variables including age, sex, cardiovascular risk factors, electrocardiography, and hs-cTn were included in the ARTEMIS models. In the validation and generalization cohorts, excellent discriminative performance was confirmed, superior to hs-cTn only. For the serial hs-cTn measurement model, AUC ranged from 0.92 to 0.98. Good calibration was observed. Using a single hs-cTn measurement, the ARTEMIS model allowed direct rule-out of MI with very high and similar safety but up to tripled efficiency compared to the guideline- recommended strategy.Conclusion We developed and validated diagnostic models to accurately estimate the individual probability of MI, which allow for variable hs-cTn use and flexible timing of resampling. Their digital application may provide rapid, safe and efficient personalized patient care.
  •  
6.
  • Pickering, John W., et al. (författare)
  • Rapid Rule-out of Acute Myocardial Infarction With a Single High-Sensitivity Cardiac Troponin T Measurement Below the Limit of Detection A Collaborative Meta-analysis
  • 2017
  • Ingår i: Annals of Internal Medicine. - 0003-4819 .- 1539-3704. ; 166:10, s. 715-724
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: High-sensitivity assays for cardiac troponin T (hs-cTnT) are sometimes used to rapidly rule out acute myocardial infarction (AMI). Purpose: To estimate the ability of a single hs-cTnT concentration below the limit of detection (<0.005 mu g/L) and a nonischemic electrocardiogram (ECG) to rule out AMI in adults presenting to the emergency department (ED) with chest pain. Data Sources: EMBASE and MEDLINE without language restrictions (1 January 2008 to 14 December 2016). Study Selection: Cohort studies involving adults presenting to the ED with possible acute coronary syndrome in whom an ECG and hs-cTnT measurements were obtained and AMI outcomes adjudicated during initial hospitalization. Data Extraction: Investigators of studies provided data on the number of low-risk patients (no new ischemia on ECG and hs-cTnT measurements <0.005 mu g/L) and the number who had AMI during hospitalization (primary outcome) or a major adverse cardiac event (MACE) or death within 30 days (secondary outcomes), by risk classification (low or not low risk). Two independent epidemiologists rated risk of bias of studies. Data Synthesis: Of 9241 patients in 11 cohort studies, 2825 (30.6%) were classified as low risk. Fourteen (0.5%) low-risk patients had AMI. Sensitivity of the risk classification for AMI ranged from 87.5% to 100% in individual studies. Pooled estimated sensitivity was 98.7% (95% CI, 96.6% to 99.5%). Sensitivity for 30-day MACEs ranged from 87.9% to 100%; pooled sensitivity was 98.0% (CI, 94.7% to 99.3%). No low-risk patients died. Limitation: Few studies, variation in timing and methods of reference standard troponin tests, and heterogeneity of risk and prevalence of AMI across studies. Conclusion: A single hs-cTnT concentration below the limit of detection in combination with a nonischemic ECG may successfully rule out AMI in patients presenting to EDs with possible emergency acute coronary syndrome.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy