SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Periale L) "

Sökning: WFRF:(Periale L)

  • Resultat 1-10 av 14
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Rubbia, C, et al. (författare)
  • Underground operation of the ICARUS T600 LAr-TPC : first results
  • 2011
  • Ingår i: Journal of Instrumentation. ; 6:07
  • Tidskriftsartikel (refereegranskat)abstract
    • Important open questions are still present in fundamental Physics and Cosmology, like the nature of Dark Matter, the matter-antimatter asymmetry and the validity of the Standard Model of particle interactions. Addressing these questions requires a new generation of massive particle detectors to explore the subatomic and astrophysical worlds. ICARUS T600 is the first large mass (760 tons) example of a new generation of detectors able to combine the imaging capabilities of the old famous “bubble chamber” with the excellent energy measurement of huge electronic detectors. ICARUS T600 now operates at the Gran Sasso underground laboratory and is used to study cosmic rays, neutrino oscillations and the proton decay. The potential for doing physics of this novel telescope is presented through a few examples of neutrino interactions reconstructed with unprecedented detail. Detector design and early operation are also reported.
  •  
2.
  • Ankowski, A., et al. (författare)
  • Energy reconstruction of electromagnetic showers from Ν0 decays with the ICARUS T600 liquid argon TPC
  • 2010
  • Ingår i: Acta Physica Polonica, Series B.. - 1509-5770 .- 0587-4254. ; 41:1, s. 103-125
  • Tidskriftsartikel (refereegranskat)abstract
    • We discuss the ICARUS T600 detector capabilities in electromagnetic shower reconstruction through the analysis of a sample of 212 events, coming from the 2001 Pavia surface test run, of hadronic interactions leading to the production of π 0 mesons. Methods of shower energy and shower direction measurements were developed and the invariant mass of the photon pairs was reconstructed. The (γγ) invariant mass was found to be consistent with the value of the π 0 mass. The resolution of the reconstructed π 0 mass was found to be equal to 27.3%. An improved analysis, carried out in order to clean the full event sample from the events measured in the crowded environment, mostly due to the trigger conditions, gave a π 0 mass resolution of 16.1%, significantly better than the one evaluated for the full event sample. The trigger requirement of the coincidence of at least four photo-multiplier signals favored the selection of events with a strong pile up of cosmic ray tracks and interactions. Hence a number of candidate π 0 events were heavily contaminated by other tracks and had to be rejected. Monte Carlo simulations of events with π 0 production in hadronic and neutrino interactions confirmed the validity of the shower energy and shower direction reconstruction methods applied to the real data.
  •  
3.
  • Ankowski, A, et al. (författare)
  • Energy reconstruction of electromagnetic showers from π0 decays with the ICARUS T600 liquid argon TPC
  • 2010
  • Ingår i: Acta Physica Polonica B. - : Jagellonian University. - 0587-4254 .- 1509-5770. ; 41:1, s. 103-125
  • Tidskriftsartikel (refereegranskat)abstract
    • We discuss the ICARUS T600 detector capabilities in electromagnetic shower reconstruction through the analysis of a sample of 212 events, coming from the 2001 Pavia surface test run, of hadronic interactions leading to the production of π0 mesons. Methods of shower energy and shower direction measurements were developed and the invariant mass of the photon pairs was reconstructed. The (γ,γ) invariant mass was found to be consistent with the value of the π0 mass. The resolution of the reconstructed π0 mass was found to be equal to 27.3%. An improved analysis, carried out in order to clean the full event sample from the events measured in the crowded environment, mostly due to the trigger conditions, gave a π0 mass resolution of 16.1%, significantly better than the one evaluated for the full event sample. The trigger requirement of the coincidence of at least four photo-multiplier signals favored the selection of events with a strong pile up of cosmic ray tracks and interactions. Hence a number of candidate π0 events were heavily contaminated by other tracks and had to be rejected. Monte Carlo simulations of events with π0 production in hadronic and neutrino interactions confirmed the validity of the shower energy and shower direction reconstruction methods applied to the real data.
  •  
4.
  • Carlson, P., et al. (författare)
  • Beyond the RICH : innovative photosensitive gaseous detectors for new fields of applications
  • 2003
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 502:1, s. 189-194
  • Tidskriftsartikel (refereegranskat)abstract
    • We have developed and successfully used several innovative designs of detectors with solid photocathodes. The main advantage of these detectors is that rather high gains (> 10(4)) can be achieved in a single multiplication step. This is possible by, for instance, exploiting the secondary electron multiplication and limiting the energy of the steamers by distributed resistivity. The single step approach also allows a very good position resolution to be achieved in some devices: 50 mum on line without applying any treatment method (like center of gravity). The main focus of our report is new fields of applications for these detectors and the optimization of their designs for such purposes.
  •  
5.
  • Di Mauro, A., et al. (författare)
  • A New GEM-like Imaging Detector with Electrodes Coated with Resistive Layers
  • 2006
  • Ingår i: 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6. - : IEEE. - 9781424405619 ; , s. 3852-3859
  • Konferensbidrag (refereegranskat)abstract
    • We have developed and tested several prototypes of GEM-like detectors with electrodes coated with resistive layers. These detectors can operate stably at gains close to 10(5) and if discharges appear at higher gains the protective layers restrict their energies so that they do not damage either the detector or the readout electronics. We discovered that the cathodes of these detectors could be coated by CsI layers and in such a way the detectors gain high efficiency for the UV photons. We also demonstrated that such detectors can operate stably in the cascade mode and high overall gains (similar to 10(6)) are reachable. This opens applications in several areas, for example in RICH or in noble liquid TPCs. The simplified prototype of the RICH detector was built and successfully tested in the laboratory. The first results of operation of the new detectors at cryogenic temperatures are given.
  •  
6.
  • Di Mauro, A., et al. (författare)
  • Development of innovative micro-pattern gaseous detectors with resistive electrodes and first results of their applications
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 581:1-2, s. 225-231
  • Tidskriftsartikel (refereegranskat)abstract
    • The paper summarizes our latest progress in the development of newly introduced micro-pattern gaseous detectors with resistive electrodes. These resistive electrodes protect the detector and the front-end electronics in case of occasional discharges and thus make the detectors very robust and reliable in operation. As an example, we describe in greater detail a recently developed GEM-like detector, fully spark-protected with electrodes made of resistive kapton. We discovered that all resistive layers used in these studies (including kapton) that are coated with photosensitive layers, such as CsI, can be used as efficient photocathodes for detectors operating in a pulse counting mode. There is a description of the first applications of such detectors combined with CsI or SbCs photocathodes for the detection of UV photons at room and cryogenic temperatures.
  •  
7.
  • Periale, L., et al. (författare)
  • A study of the operation of especially designed photosensitive gaseous detectors at cryogenic temperatures
  • 2006
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 567:1, s. 381-385
  • Tidskriftsartikel (refereegranskat)abstract
    • In some experiments and applications there is need for large-area photosensitive detectors to operate at cryogenic temperatures. Nowadays, vacuum PMs are usually used for this purpose. We have developed special designs of planar photosensitive gaseous detectors able to operate at cryogenic temperatures. Such detectors are much cheaper than PMs and are almost insensitive to magnetic fields. Results of systematic measurements of their quantum efficiencies, the maximum achievable gains and long-term stabilities will be presented. The successful operation of these detectors open realistic possibilities in replacing PMs by photosensitive gaseous detectors in some applications dealing with cryogenic liquids; for example in experiments using noble liquid TPCs or noble liquid scintillating calorimeters.
  •  
8.
  •  
9.
  • Periale, L., et al. (författare)
  • Photosensitive gaseous detectors for cryogenic temperature applications
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 573:1-2, s. 302-305
  • Tidskriftsartikel (refereegranskat)abstract
    • There are several proposals and projects today for building LXe time projection chambers (TPCs) for dark matter search. Important elements of these TPCs are the photomultipliers operating either inside LXe or in vapours above the liquid. We have recently demonstrated that photosensitive gaseous detectors (wire type and hole type) can operate perfectly well, until temperatures of LN2. In this paper, results of systematic studies of operation of the photosensitive version of these detectors (combined with reflective or semi-transparent CsI photocathodes) in the temperature interval of 300-150K are presented. In particular, it was demonstrated that both sealed and flushed by a gas detectors could operate at a quite stable fashion in a year/time scale. Obtained results strongly indicate that they can be cheap and simple alternatives to photomultipliers or avalanche solid-state detectors in LXe TPC applications.
  •  
10.
  • Periale, L., et al. (författare)
  • Successful operation of hole-type gaseous detectors at cryogenic temperatures
  • 2004
  • Ingår i: 2004 IEEE Nuclear Science Symposium Conference Record. - 0780387007 ; , s. 1147-1151
  • Konferensbidrag (refereegranskat)abstract
    • We have demonstrated that hole-type gaseous detectors, GEMs and capillary plates, can operate up to 77 K. For example, a single capillary plate can operate at gains of above 103 in the entire temperature interval between 300 until 77 K. The same capillary plate combined with Csi photocathodes could operate perfectly well at gains (depending on gas mixtures) of 100-1000. Obtained results may open new fields of applications for capillary plates as detectors of UV light and charge particles at cryogenic temperatures: noble liquid TPCs, WIMP detectors or LXe scintillating calorimeters and cryogenic PETs.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 14

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy