SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Perlet C) "

Sökning: WFRF:(Perlet C)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Perlet, C, et al. (författare)
  • Multicenter study for the evaluation of a dedicated biopsy device for MR-guided vacuum biopsy of the breast
  • 2002
  • Ingår i: European Radiology. - : Springer Science and Business Media LLC. - 0938-7994 .- 1432-1084. ; 12:6, s. 1463-1470
  • Tidskriftsartikel (refereegranskat)abstract
    • The purpose of this multicenter study was to determine the accuracy and clinical value of a dedicated breast biopsy system which allows for MR-guided vacuum biopsy (VB) of contrast-enhancing lesions. In five European centers, MR-guided 11-gauge VB was performed on 341 lesions. In 7 cases VB was unsuccessful. This was immediately realized on postinterventional images or direct follow-up combined with histopathology-imaging correlation; thus, a false-negative diagnosis was avoided. Histology of 334 successful biopsies yielded 84 (25%) malignancies, 17 (5%) atypical ductal hyperplasias, and 233 (70%) benign entities. Verification of malignant or borderline lesions included re-excision of the biopsy cavity. Benign histologic biopsy results were verified by retrospective correlation with the pre- and postinterventional MRI and by subsequent follow-up. Our results indicate that MR-guided VB, in combination with the dedicated biopsy coil, offers the possibility to accurately diagnose even very small lesions that can only be visualized or localized by MRI.
  •  
2.
  • Perlet, C, et al. (författare)
  • Magnetic resonance-guided, vacuum-assisted breast biopsy - Results from a European Multicenter Study of 538 lesions
  • 2006
  • Ingår i: Cancer. - : Wiley. - 1097-0142 .- 0008-543X. ; 106:5, s. 982-990
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND. The objective of this study was to determine the accuracy, reproducibility, and clinical value of magnetic resonance (MR)-guided, vacuum-assisted breast biopsy (MR-VAB) in a prospective, multicenter study. METHODS. in 5 European centers, MR-VAB was performed or attempted on 538 suspicious lesions that were visible or could targeted only by MR imaging (MRI). Verification of malignant or borderline lesions included reexcision of the biopsy cavity. Benign biopsy results were verified by retrospective correlation of histology with preinterventional and postinterventional MRI studies. Follow-up of 24-48 months (median, 32 months) was available for 491 of 538 patients. RESULTS. MR-VAB was unsuccessful or was not completed in 21 of 538 patients, for which an immediate repeat biopsy was recommended. Five hundred seventeen of 538 performed VAB procedures (96%) were successful. Histology yielded 138 (27%) malignancies, 17 (3%) atypical ductal hyperplasias, and 362 (70%) benign entities. No false-negative diagnoses occurred among the 517 successful MR-VAB procedures. The positive predictive value of VAB depended on patient preselection, which differed according to the indication for the initial MRI study. CONCLUSIONS. The results of this study indicated that MR-VAB offers excellent accuracy. Small lesion size did not prove to be a limitation.
  •  
3.
  • Prat, X, et al. (författare)
  • European quadricentric evaluation of a breast MR biopsy and localization device: technical improvements based on phase-I evaluation
  • 2002
  • Ingår i: European Radiology. - : Springer Science and Business Media LLC. - 0938-7994 .- 1432-1084. ; 12:7, s. 1720-1727
  • Tidskriftsartikel (refereegranskat)abstract
    • Our purpose was to report about technical success, problems and solutions, as experienced in a first multicentre study on MR-guided localisation or vacuum biopsy of breast lesions. The study was carried out at four European sites using a dedicated prototype breast biopsy device. Experiences with 49 scheduled localisation procedures and 188 vacuum biopsies are reported. Apart from 35 dropped indications, one localisation procedure and 9 vacuum biopsies were not possible (3 times space problems due to obesity, 2 times too strong compression, 3 times impaired access froth medially, 2 times impaired access due to a metal bar). Problems due to too strong compression were recognised by repeat MR without compression. During the procedure problems leading to an uncertain result occurred in eight vacuum biopsies, two related to the procedure: one limited access, and one strong post-biopsy enhancement. Improvements after phase-I study concerned removal of the metal bar, development of an improved medial access, of a profile imitating the biopsy gun, optimisation of compression plates and improved software support. The partners agreed that the improvements answered all important technical problems.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy