SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Petersson Klara) "

Sökning: WFRF:(Petersson Klara)

  • Resultat 1-10 av 16
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Stroth, U., et al. (författare)
  • Progress from ASDEX Upgrade experiments in preparing the physics basis of ITER operation and DEMO scenario development
  • 2022
  • Ingår i: Nuclear Fusion. - : IOP Publishing. - 1741-4326 .- 0029-5515. ; 62:4
  • Tidskriftsartikel (refereegranskat)abstract
    • An overview of recent results obtained at the tokamak ASDEX Upgrade (AUG) is given. A work flow for predictive profile modelling of AUG discharges was established which is able to reproduce experimental H-mode plasma profiles based on engineering parameters only. In the plasma center, theoretical predictions on plasma current redistribution by a dynamo effect were confirmed experimentally. For core transport, the stabilizing effect of fast ion distributions on turbulent transport is shown to be important to explain the core isotope effect and improves the description of hollow low-Z impurity profiles. The L-H power threshold of hydrogen plasmas is not affected by small helium admixtures and it increases continuously from the deuterium to the hydrogen level when the hydrogen concentration is raised from 0 to 100%. One focus of recent campaigns was the search for a fusion relevant integrated plasma scenario without large edge localised modes (ELMs). Results from six different ELM-free confinement regimes are compared with respect to reactor relevance: ELM suppression by magnetic perturbation coils could be attributed to toroidally asymmetric turbulent fluctuations in the vicinity of the separatrix. Stable improved confinement mode plasma phases with a detached inner divertor were obtained using a feedback control of the plasma β. The enhanced D α H-mode regime was extended to higher heating power by feedback controlled radiative cooling with argon. The quasi-coherent exhaust regime was developed into an integrated scenario at high heating power and energy confinement, with a detached divertor and without large ELMs. Small ELMs close to the separatrix lead to peeling-ballooning stability and quasi continuous power exhaust. Helium beam density fluctuation measurements confirm that transport close to the separatrix is important to achieve the different ELM-free regimes. Based on separatrix plasma parameters and interchange-drift-Alfvén turbulence, an analytic model was derived that reproduces the experimentally found important operational boundaries of the density limit and between L- and H-mode confinement. Feedback control for the X-point radiator (XPR) position was established as an important element for divertor detachment control. Stable and detached ELM-free phases with H-mode confinement quality were obtained when the XPR was moved 10 cm above the X-point. Investigations of the plasma in the future flexible snow-flake divertor of AUG by means of first SOLPS-ITER simulations with drifts activated predict beneficial detachment properties and the activation of an additional strike point by the drifts.
  •  
2.
  • Ahmad Tajudin, Asilah, et al. (författare)
  • Integrated acoustic immunoaffinity-capture (IAI) platform for detection of PSA from whole blood samples.
  • 2013
  • Ingår i: Lab on a Chip. - : Royal Society of Chemistry (RSC). - 1473-0189 .- 1473-0197. ; 13:9, s. 1790-1796
  • Tidskriftsartikel (refereegranskat)abstract
    • On-chip detection of low abundant protein biomarkers is of interest to enable point-of-care diagnostics. Using a simple form of integration, we have realized an integrated microfluidic platform for the detection of prostate specific antigen (PSA), directly in anti-coagulated whole blood. We combine acoustophoresis-based separation of plasma from undiluted whole blood with a miniaturized immunoassay system in a polymer manifold, demonstrating improved assay speed on our Integrated Acoustic Immunoaffinity-capture (IAI) platform. The IAI platform separates plasma from undiluted whole blood by means of acoustophoresis and provides cell free plasma of clinical quality at a rate of 10 uL/min for an online immunoaffinity-capture of PSA on a porous silicon antibody microarray. The whole blood input (hematocrit 38-40%) rate was 50 μl min(-1) giving a plasma volume fraction yield of ≈33%. PSA was immunoaffinity-captured directly from spiked female whole blood samples at clinically significant levels of 1.7-100 ng ml(-1) within 15 min and was subsequently detected via fluorescence readout, showing a linear response over the entire range with a coefficient of variation of 13%.
  •  
3.
  •  
4.
  •  
5.
  • Frimodt-Møller, Niels, et al. (författare)
  • Apramycin efficacy against carbapenem- and aminoglycoside-resistant Escherichia coli and Klebsiella pneumoniae in murine bloodstream infection models
  • 2024
  • Ingår i: International Journal of Antimicrobial Agents. - : Elsevier. - 0924-8579 .- 1872-7913. ; 64:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundThe aminoglycoside apramycin has been proposed as a drug candidate for the treatment of critical Gram-negative systemic infections. However, the potential of apramycin in the treatment of drug-resistant bloodstream infections (BSIs) has not yet been assessed.MethodsThe resistance gene annotations of 40 888 blood-culture isolates were analysed. In vitro profiling of apramycin comprised cell-free translation assays, broth microdilution, and frequency of resistance determination. The efficacy of apramycin was studied in a mouse peritonitis model for a total of nine Escherichia coli and Klebsiella pneumoniae isolates.ResultsGenotypic aminoglycoside resistance was identified in 87.8% of all 6973 carbapenem-resistant Enterobacterales blood-culture isolates, colistin resistance was shown in 46.4% and apramycin in 2.1%. Apramycin activity against methylated ribosomes was > 100-fold higher than that for other aminoglycosides. Frequencies of resistance were < 10-9 at 8 × minimum inhibitory concentration (MIC). Tentative epidemiological cut-offs (TECOFFs) were determined as 8 µg/mL for E. coli and 4 µg/mL for K. pneumoniae. A single dose of 5 to 13 mg/kg resulted in a 1-log colony-forming unit (CFU) reduction in the blood and peritoneum. Two doses of 80 mg/kg resulted in an exposure that resembles the AUC observed for a single 30 mg/kg dose in humans and led to complete eradication of carbapenem- and aminoglycoside-resistant bacteraemia.ConclusionEncouraging coverage and potent in vivo efficacy against a selection of highly drug-resistant Enterobacterales isolates in the mouse peritonitis model warrants the conduct of clinical studies to validate apramycin as a drug candidate for the prophylaxis and treatment of BSI.
  •  
6.
  •  
7.
  • Murari, A., et al. (författare)
  • A control oriented strategy of disruption prediction to avoid the configuration collapse of tokamak reactors
  • 2024
  • Ingår i: Nature Communications. - 2041-1723 .- 2041-1723. ; 15:1
  • Tidskriftsartikel (refereegranskat)abstract
    • The objective of thermonuclear fusion consists of producing electricity from the coalescence of light nuclei in high temperature plasmas. The most promising route to fusion envisages the confinement of such plasmas with magnetic fields, whose most studied configuration is the tokamak. Disruptions are catastrophic collapses affecting all tokamak devices and one of the main potential showstoppers on the route to a commercial reactor. In this work we report how, deploying innovative analysis methods on thousands of JET experiments covering the isotopic compositions from hydrogen to full tritium and including the major D-T campaign, the nature of the various forms of collapse is investigated in all phases of the discharges. An original approach to proximity detection has been developed, which allows determining both the probability of and the time interval remaining before an incoming disruption, with adaptive, from scratch, real time compatible techniques. The results indicate that physics based prediction and control tools can be developed, to deploy realistic strategies of disruption avoidance and prevention, meeting the requirements of the next generation of devices.
  •  
8.
  • Ohlsson, Pelle, et al. (författare)
  • Acoustic impedance matched buffers enable separation of bacteria from blood cells at high cell concentrations
  • 2018
  • Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 8:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Sepsis is a common and often deadly systemic response to an infection, usually caused by bacteria. The gold standard for finding the causing pathogen in a blood sample is blood culture, which may take hours to days. Shortening the time to diagnosis would significantly reduce mortality. To replace the time-consuming blood culture we are developing a method to directly separate bacteria from red and white blood cells to enable faster bacteria identification. The blood cells are moved from the sample flow into a parallel stream using acoustophoresis. Due to their smaller size, the bacteria are not affected by the acoustic field and therefore remain in the blood plasma flow and can be directed to a separate outlet. When optimizing for sample throughput, 1 ml of undiluted whole blood equivalent can be processed within 12.5 min, while maintaining the bacteria recovery at 90% and the blood cell removal above 99%. That makes this the fastest label-free microfluidic continuous flow method per channel to separate bacteria from blood with high bacteria recovery (>80%). The high throughput was achieved by matching the acoustic impedance of the parallel stream to that of the blood sample, to avoid that acoustic forces relocate the fluid streams.
  •  
9.
  • Ohlsson, Pelle, et al. (författare)
  • Acoustic separation of bacteria from blood cells at high cell concentrations enabled by acoustic impedance matched buffers
  • 2014
  • Ingår i: 18th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2014. - 9780979806476 ; , s. 388-390
  • Konferensbidrag (refereegranskat)abstract
    • We have developed a method to separate bacteria from red and white blood cells (henceforth collectively called blood cells) using acoustophoresis, for subsequent PCR detection. To maximize throughput, we have now investigated the effect of increased cell concentration on the separation. Increasing the blood concentration drastically decreases bacteria recovery, but we show that this can be remedied by optimizing the acoustic impedance of the center buffer. This way we can recover 89% of the bacteria while removing more than 99.8% of the blood cells from 1 ml whole blood within 25 min, paving the way for new sepsis diagnostics methods.
  •  
10.
  • Ohlsson, Pelle, et al. (författare)
  • Integrated Acoustic Separation, Enrichment, and Microchip Polymerase Chain Reaction Detection of Bacteria from Blood for Rapid Sepsis Diagnostics
  • 2016
  • Ingår i: Analytical Chemistry. - : American Chemical Society (ACS). - 0003-2700 .- 1520-6882. ; 88:19, s. 9403-9411
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper describes an integrated microsystem for rapid separation, enrichment, and detection of bacteria from blood, addressing the unmet clinical need for rapid sepsis diagnostics. The blood sample is first processed in an acoustophoresis chip, where red blood cells are focused to the center of the channel by an acoustic standing wave and sequentially removed. The bacteria-containing plasma proceeds to a glass capillary with a localized acoustic standing wave field where the bacteria are trapped onto suspended polystyrene particles. The trapped bacteria are subsequently washed while held in the acoustic trap and released into a polymer microchip containing dried polymerase chain reaction (PCR) reagents, followed by thermocycling for target sequence amplification. The entire process is completed in less than 2 h. Testing with Pseudomonas putida spiked into whole blood revealed a detection limit of 1000 bacteria/mL for this first-generation analysis system. In samples from septic patients, the system was able to detect Escherichia coli in half of the cases identified by blood culture. This indicates that the current system detects bacteria in patient samples in the upper part of the of clinically relevant bacteria concentration range and that a further developed acoustic sample preparation system may open the door for a new and faster automated method to diagnose sepsis.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 16

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy