SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Petit Steven F.) "

Sökning: WFRF:(Petit Steven F.)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Kaushik, Sandeep S., et al. (författare)
  • Region of interest focused MRI to synthetic CT translation using regression and segmentation multi-task network
  • 2023
  • Ingår i: Physics in Medicine and Biology. - : Institute of Physics (IOP). - 0031-9155 .- 1361-6560. ; 68:19
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: In MR-only clinical workflow, replacing CT with MR image is of advantage for workflow efficiency and reduces radiation to the patient. An important step required to eliminate CT scan from the workflow is to generate the information provided by CT via an MR image. In this work, we aim to demonstrate a method to generate accurate synthetic CT (sCT) from an MR image to suit the radiation therapy (RT) treatment planning workflow. We show the feasibility of the method and make way for a broader clinical evaluation.Approach: We present a machine learning method for sCT generation from zero-echo-time (ZTE) MRI aimed at structural and quantitative accuracies of the image, with a particular focus on the accurate bone density value prediction. The misestimation of bone density in the radiation path could lead to unintended dose delivery to the target volume and results in suboptimal treatment outcome. We propose a loss function that favors a spatially sparse bone region in the image. We harness the ability of the multi-task network to produce correlated outputs as a framework to enable localization of region of interest (RoI) via segmentation, emphasize regression of values within RoI and still retain the overall accuracy via global regression. The network is optimized by a composite loss function that combines a dedicated loss from each task.Main results: We have included 54 brain patient images in this study and tested the sCT images against reference CT on a subset of 20 cases. A pilot dose evaluation was performed on 9 of the 20 test cases to demonstrate the viability of the generated sCT in RT planning. The average quantitative metrics produced by the proposed method over the test set were-(a) mean absolute error (MAE) of 70 ± 8.6 HU; (b) peak signal-to-noise ratio (PSNR) of 29.4 ± 2.8 dB; structural similarity metric (SSIM) of 0.95 ± 0.02; and (d) Dice coefficient of the body region of 0.984 ± 0.Significance: We demonstrate that the proposed method generates sCT images that resemble visual characteristics of a real CT image and has a quantitative accuracy that suits RT dose planning application. We compare the dose calculation from the proposed sCT and the real CT in a radiation therapy treatment planning setup and show that sCT based planning falls within 0.5% target dose error. The method presented here with an initial dose evaluation makes an encouraging precursor to a broader clinical evaluation of sCT based RT planning on different anatomical regions.
  •  
2.
  • Wang, Yibing, et al. (författare)
  • An individualized strategy to estimate the effect of deformable registration uncertainty on accumulated dose in the upper abdomen
  • 2018
  • Ingår i: Physics in Medicine and Biology. - : IOP PUBLISHING LTD. - 0031-9155 .- 1361-6560. ; 63:12
  • Tidskriftsartikel (refereegranskat)abstract
    • In the abdomen, it is challenging to assess the accuracy of deformable image registration (DIR) for individual patients, due to the lack of clear anatomical landmarks, which can hamper clinical applications that require high accuracy DIR, such as adaptive radiotherapy. In this study, we propose and evaluate a methodology for estimating the impact of uncertainties in DIR on calculated accumulated dose in the upper abdomen, in order to aid decision making in adaptive treatment approaches. Sixteen liver metastasis patients treated with SBRT were evaluated. Each patient had one planning and three daily treatment CT-scans. Each daily CT scan was deformably registered 132 times to the planning CT-scan, using a wide range of parameter settings for the registration algorithm. A subset of realistic registrations was then objectively selected based on distances between mapped and target contours. The underlying 3D transformations of these registrations were used to assess the corresponding uncertainties in voxel positions, and delivered dose, with a focus on accumulated maximum doses in the hollow OARs, i.e. esophagus, stomach, and duodenum. The number of realistic registrations varied from 5 to 109, depending on the patient, emphasizing the need for individualized registration parameters. Considering for all patients the realistic registrations, the 99th percentile of the voxel position uncertainties was 5.6 +/- 3.3 mm. This translated into a variation (difference between 1st and 99th percentile) in accumulated Dmax in hollow OARs of up to 3.3 Gy. For one patient a violation of the accumulated stomach dose outside the uncertainty band was detected. The observed variation in accumulated doses in the OARs related to registration uncertainty, emphasizes the need to investigate the impact of this uncertainty for any DIR algorithm prior to clinical use for dose accumulation. The proposed method for assessing on an individual patient basis the impact of uncertainties in DIR on accumulated dose is in principle applicable for all DIR algorithms allowing variation in registration parameters.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy