SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Petrasi Z) "

Sökning: WFRF:(Petrasi Z)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Gyongyosi, M, et al. (författare)
  • Platelet activation and high tissue factor level predict acute stent thrombosis in pig coronary arteries: prothrombogenic response of drug-eluting or bare stent implantation within the first 24 hours
  • 2006
  • Ingår i: Thrombosis and haemostasis. - : Georg Thieme Verlag KG. - 0340-6245 .- 2567-689X. ; 96:2, s. 202-209
  • Tidskriftsartikel (refereegranskat)abstract
    • Increased thrombogenicity of drug-eluting stents (DESs) has recently been reported.The aim of the present study was to investigate the prothrombogenic effect of DESs and Bare stents, and determine factors predictive of acute stent thrombosis (AST) in preclinical experiments using new stent design or coating.Circulating preand post-stenting parameters of platelet activation (mean platelet volume, MPV; platelet distribution width, platelet large cell ratio), thrombin activation (thrombin-antithrombin complex, TAT and prothrombin fragments, F1+2), tissue factor antigen (TF-ag) and -activity (TF-act) and plasminogen activator inhibitor-1 (PAI-1) were measured in 141 consecutive pigs. Stent implantations were performed after pretreatment with aspirin and clopidogrel with unfractionated heparin anticoagulation. Nineteen pigs (groups AST-DES, n=12; and AST-Bare, n=7) died mean 6.3 ± 2.9 h after stent implantation from AST.The remaining 122 control (C) pigs (groups C-DES,n=76,and C-Bare,n=46) survived the 1-month follow-up. Non-significantly elevated levels of post-stent F1+2 and TAT were measured in AST groups. Post-stenting MPV was increased significantly in the groups ASTDES and AST-Bare as compared with the groups C-DES and C-Bare (11.73 ± 1.12 and 11.6 ± 0.68 vs. 8.85 ± 0.78 and 9.04 ± 0.81 fL; p<0.001), similarly toTF-ag (189.1± 87.5 and 127 ± 34.9 vs. 42.5 ± 24.6 and 35.3 ± 37.6 pg/ml; p<0.001, respectively),TF-act (3.23 ± 0.95 and 2.73 ± 1.68 vs. 1.43 ± 1.12 and 1.61 ± 1.31 pM; p<0.01, respectively) and PAI-1 (99.1 ± 15.8 and 99 ± 14.7 vs.53.4 ± 40.2 and 46.9 ± 42.4 ng/ml;p<0.01,respectively).Multivariate analysis revealed elevated post-stenting plasma levels of TF-ag (p=0.016) and MPV (p=0.001) as independent risk factors for developing AST within the first 24 h in a porcine coronary stent model.
  •  
2.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy