SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Phelan Liam) "

Sökning: WFRF:(Phelan Liam)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Beal, Jacob, et al. (författare)
  • Robust estimation of bacterial cell count from optical density
  • 2020
  • Ingår i: Communications Biology. - : Springer Science and Business Media LLC. - 2399-3642. ; 3:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data.
  •  
2.
  • Pande, Rupaly, et al. (författare)
  • External validation of postoperative pancreatic fistula prediction scores in pancreatoduodenectomy : a systematic review and meta-analysis
  • 2022
  • Ingår i: HPB. - : Elsevier BV. - 1365-182X. ; 24:3, s. 287-298
  • Forskningsöversikt (refereegranskat)abstract
    • Background: Multiple risk scores claim to predict the probability of postoperative pancreatic fistula (POPF) after pancreatoduodenectomy. It is unclear which scores have undergone external validation and are the most accurate. The aim of this study was to identify risk scores for POPF, and assess the clinical validity of these scores. Methods: Areas under receiving operator characteristic curve (AUROCs) were extracted from studies that performed external validation of POPF risk scores. These were pooled for each risk score, using intercept-only random-effects meta-regression models. Results: Systematic review identified 34 risk scores, of which six had been subjected to external validation, and so included in the meta-analysis, (Tokyo (N=2 validation studies), Birmingham (N=5), FRS (N=19), a-FRS (N=12), m-FRS (N=3) and ua-FRS (N=3) scores). Overall predictive accuracies were similar for all six scores, with pooled AUROCs of 0.61, 0.70, 0.71, 0.70, 0.70 and 0.72, respectively. Considerably heterogeneity was observed, with I2 statistics ranging from 52.1-88.6%. Conclusion: Most risk scores lack external validation; where this was performed, risk scores were found to have limited predictive accuracy. Consensus is needed for which score to use in clinical practice. Due to the limited predictive accuracy, future studies to derive a more accurate risk score are warranted.
  •  
3.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy