SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Policarpo A) "

Sökning: WFRF:(Policarpo A)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Glasbey, JC, et al. (författare)
  • 2021
  • swepub:Mat__t
  •  
2.
  • Abbondanno, U, et al. (författare)
  • The data acquisition system of the neutron time-of-flight facility n_TOF at CERN
  • 2005
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 538:1-3, s. 692-702
  • Tidskriftsartikel (refereegranskat)abstract
    • The n_TOF facility at CERN has been designed for the measurement of neutron capture, fission and (n, xn) cross-sections with high accuracy. This requires a flexible and-due to the high instantaneous neutron flux-almost dead time free data acquisition system. A scalable and versatile data solution has been designed based on 8-bit flash-ADCs with sampling rates up to 2 GHz and 8 Mbyte memory buffer. The software is written in C and C++ and is running on PCs equipped with RedHat Linux.
  •  
3.
  • Blanco, A, et al. (författare)
  • Progress in timing Resistive Plate Chambers
  • 2004
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 535:1-2, s. 272-276
  • Tidskriftsartikel (refereegranskat)abstract
    • Timing RPCs are Resistive Plate Chambers made with glass and metal electrodes separated by precision spacers. Typical gas gaps are a few hundred micrometers wide. Such counters were introduced in 1999 and have since reached timing accuracies below 50 ps sigma with efficiencies above 99% for MIPs. Applications in high-energy physics have already taken place with several more under study. Some recent developments include the extension of the counting rate capability by over one order of magnitude, to 25 kHz/cm(2), with time resolutions below 100 ps sigma. A prototype RPC-based Positron Emission Tomograph yielded a reconstructed point-source resolution of 0.6 mm FWHM and a modified timing RPC design, featuring 50 mum pitch anode strips, allowed to reach extremely good position resolution for hard X-rays in digital readout mode. An analytically solvable model has allowed us to clarify the basic factors influencing the time resolution.
  •  
4.
  • Lopes, L, et al. (författare)
  • Development of high-rate timing RPCs
  • 2004
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 533:1-2, s. 69-73
  • Tidskriftsartikel (refereegranskat)abstract
    • For many applications of RPCs to time-of-flight counters in heavy ion experiments the expansion to much higher values of the counting rate capability, so far limited to around 2 kHz/cm(2) is of fundamental importance. To address this issue we developed single-gap timing RPCs with resistive electrodes made from a commercially available plastic material. Tests performed in photon beams yielded a time resolution around 90 ps sigma, essentially unchanged from 2 kHz/ cm(2) to 27 kHZ/cm(2). This result establishes the basic feasibility of timing measurements with RPCs at rates of tens of kHZ/cm(2), keeping a time resolution below 100 ps a and using plastic electrode materials.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy