SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Poulsen Hans S.) "

Sökning: WFRF:(Poulsen Hans S.)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Muscarella, Robert, et al. (författare)
  • The global abundance of tree palms
  • 2020
  • Ingår i: Global Ecology and Biogeography. - : Wiley. - 1466-822X .- 1466-8238. ; 29:9, s. 1495-1514
  • Tidskriftsartikel (refereegranskat)abstract
    • AimPalms are an iconic, diverse and often abundant component of tropical ecosystems that provide many ecosystem services. Being monocots, tree palms are evolutionarily, morphologically and physiologically distinct from other trees, and these differences have important consequences for ecosystem services (e.g., carbon sequestration and storage) and in terms of responses to climate change. We quantified global patterns of tree palm relative abundance to help improve understanding of tropical forests and reduce uncertainty about these ecosystems under climate change.LocationTropical and subtropical moist forests.Time periodCurrent.Major taxa studiedPalms (Arecaceae).MethodsWe assembled a pantropical dataset of 2,548 forest plots (covering 1,191 ha) and quantified tree palm (i.e., ≥10 cm diameter at breast height) abundance relative to co‐occurring non‐palm trees. We compared the relative abundance of tree palms across biogeographical realms and tested for associations with palaeoclimate stability, current climate, edaphic conditions and metrics of forest structure.ResultsOn average, the relative abundance of tree palms was more than five times larger between Neotropical locations and other biogeographical realms. Tree palms were absent in most locations outside the Neotropics but present in >80% of Neotropical locations. The relative abundance of tree palms was more strongly associated with local conditions (e.g., higher mean annual precipitation, lower soil fertility, shallower water table and lower plot mean wood density) than metrics of long‐term climate stability. Life‐form diversity also influenced the patterns; palm assemblages outside the Neotropics comprise many non‐tree (e.g., climbing) palms. Finally, we show that tree palms can influence estimates of above‐ground biomass, but the magnitude and direction of the effect require additional work.ConclusionsTree palms are not only quintessentially tropical, but they are also overwhelmingly Neotropical. Future work to understand the contributions of tree palms to biomass estimates and carbon cycling will be particularly crucial in Neotropical forests.
  •  
2.
  • Aslam, Tayyba N., et al. (författare)
  • A survey of preferences for respiratory support in the intensive care unit for patients with acute hypoxaemic respiratory failure
  • 2023
  • Ingår i: Acta Anaesthesiologica Scandinavica. - : WILEY. - 0001-5172 .- 1399-6576. ; 67:10, s. 1383-1394
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundWhen caring for mechanically ventilated adults with acute hypoxaemic respiratory failure (AHRF), clinicians are faced with an uncertain choice between ventilator modes allowing for spontaneous breaths or ventilation fully controlled by the ventilator. The preferences of clinicians managing such patients, and what motivates their choice of ventilator mode, are largely unknown. To better understand how clinicians preferences may impact the choice of ventilatory support for patients with AHRF, we issued a survey to an international network of intensive care unit (ICU) researchers.MethodsWe distributed an online survey with 32 broadly similar and interlinked questions on how clinicians prioritise spontaneous or controlled ventilation in invasively ventilated patients with AHRF of different severity, and which factors determine their choice.ResultsThe survey was distributed to 1337 recipients in 12 countries. Of these, 415 (31%) completed the survey either fully (52%) or partially (48%). Most respondents were identified as medical specialists (87%) or physicians in training (11%). Modes allowing for spontaneous ventilation were considered preferable in mild AHRF, with controlled ventilation considered as progressively more important in moderate and severe AHRF. Among respondents there was strong support (90%) for a randomised clinical trial comparing spontaneous with controlled ventilation in patients with moderate AHRF.ConclusionsThe responses from this international survey suggest that there is clinical equipoise for the preferred ventilator mode in patients with AHRF of moderate severity. We found strong support for a randomised trial comparing modes of ventilation in patients with moderate AHRF.
  •  
3.
  • Kim, Kyung Ho, 1984, et al. (författare)
  • Apparent Power Law Scaling of Variable Range Hopping Conduction in Carbonized Polymer Nanofibers
  • 2016
  • Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322 .- 2045-2322. ; 6
  • Tidskriftsartikel (refereegranskat)abstract
    • We induce dramatic changes in the structure of conducting polymer nanofibers by carbonization at 800 degrees C and compare charge transport properties between carbonized and pristine nanofibers. Despite the profound structural differences, both types of systems display power law dependence of current with voltage and temperature, and all measurements can be scaled into a single universal curve. We analyze our experimental data in the framework of variable range hopping and argue that this mechanism can explain transport properties of pristine polymer nanofibers as well.
  •  
4.
  • Kim, Kyung Ho, 1984, et al. (författare)
  • Probing variable range hopping lengths by magneto conductance in carbonized polymer nanofibers
  • 2018
  • Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322 .- 2045-2322. ; 8:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Using magneto transport, we probe hopping length scales in the variable range hopping conduction of carbonized polyacetylene and polyaniline nanofibers. In contrast to pristine polyacetylene nanofibers that show vanishing magneto conductance at large electric fields, carbonized polymer nanofibers display a negative magneto conductance that decreases in magnitude but remains finite with respect to the electric field. We show that this behavior of magneto conductance is an indicator of the electric field and temperature dependence of hopping length in the gradual transition from the thermally activated to the activation-less electric field driven variable range hopping transport. This reveals magneto transport as a useful tool to probe hopping lengths in the non-linear hopping regime.
  •  
5.
  • Lundemann, Michael, et al. (författare)
  • Feasibility of multi-parametric PET and MRI for prediction of tumour recurrence in patients with glioblastoma
  • 2019
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 46:3, s. 603-613
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Recurrence in glioblastoma patients often occur close to the original tumour and indicates that the current treatment is inadequate for local tumour control. In this study, we explored the feasibility of using multi-modality imaging at the time of radiotherapy planning. Specifically, we aimed to identify parameters from pre-treatment PET and MRI with potential to predict tumour recurrence. Materials and methods: Sixteen patients were prospectively recruited and treated according to established guidelines. Multi-parametric imaging with 18 F-FET PET/CT and 18 F-FDG PET/MR including diffusion and dynamic contrast enhanced perfusion MRI were performed before radiotherapy. Correlations between imaging parameters were calculated. Imaging was related to the voxel-wise outcome at the time of tumour recurrence. Within the radiotherapy target, median differences of imaging parameters in recurring and non-recurring voxels were calculated for contrast-enhancing lesion (CEL), non-enhancing lesion (NEL), and normal appearing grey and white matter. Logistic regression models were created to predict the patient-specific probability of recurrence. The most important parameters were identified using standardized model coefficients. Results: Significant median differences between recurring and non-recurring voxels were observed for FDG, FET, fractional anisotropy, mean diffusivity, mean transit time, extra-vascular, extra-cellular blood volume and permeability derived from scans prior to chemo-radiotherapy. Tissue-specific patterns of voxel-wise correlations were observed. The most pronounced correlations were observed for 18 F-FDG- and 18 F-FET-uptake in CEL and NEL. Voxel-wise modelling of recurrence probability resulted in area under the receiver operating characteristic curve of 0.77 from scans prior to therapy. Overall, FET proved to be the most important parameter for recurrence prediction. Conclusion: Multi-parametric imaging before radiotherapy is feasible and significant differences in imaging parameters between recurring and non-recurring voxels were observed. Combining parameters in a logistic regression model enabled patient-specific maps of recurrence probability, where 18 F-FET proved to be most important. This strategy could enable risk-adapted radiotherapy planning.
  •  
6.
  • Shetty, Naveen, 1988, et al. (författare)
  • Ultralow 1/f noise in epigraphene devices
  • 2024
  • Ingår i: Applied Physics Letters. - 0003-6951 .- 1077-3118. ; 124:9
  • Tidskriftsartikel (refereegranskat)abstract
    • We report the lowest recorded levels of 1/ f noise for graphene-based devices, at the level of S V / V 2 = S I / I 2 = 4.4 × 10 − 16 (1/Hz), measured at f = 10 Hz ( S V / V 2 = S I / I 2 < 10 − 16 1/Hz for f > 100 Hz) in large-area epitaxial graphene on silicon carbide (epigraphene) Hall sensors. This performance is made possible through the combination of high material quality, low contact resistance achieved by edge contact fabrication process, homogeneous doping, and stable passivation of the graphene layer. Our study explores the nature of 1/ f noise as a function of carrier density and device geometry and includes data from Hall sensors with device area range spanning over six orders of magnitude, with characteristic device length ranging from L = 1 μm to 1 mm. In optimized graphene Hall sensors, we demonstrate arrays to be a viable route to improve further the magnetic field detection: a simple parallel connection of two devices displays record-high magnetic field sensitivity at room temperature, with minimum detectable magnetic field levels down to B min = 9.5 nT/√Hz. The remarkable low levels of 1/ f noise observed in epigraphene devices hold immense capacity for the design and fabrication of scalable epigraphene-based sensors with exceptional performance.
  •  
7.
  • Shetty, Naveen, 1988, et al. (författare)
  • Ultralow 1/f noise in epigraphene devices
  • 2024
  • Ingår i: Applied Physics Letters. - : American Institute of Physics Inc.. - 0003-6951 .- 1077-3118. ; 124:9
  • Tidskriftsartikel (refereegranskat)abstract
    • We report the lowest recorded levels of 1/ f noise for graphene-based devices, at the level of S V / V 2 = S I / I 2 = 4.4 × 10 − 16 (1/Hz), measured at f = 10 Hz ( S V / V 2 = S I / I 2 < 10 − 16 1/Hz for f > 100 Hz) in large-area epitaxial graphene on silicon carbide (epigraphene) Hall sensors. This performance is made possible through the combination of high material quality, low contact resistance achieved by edge contact fabrication process, homogeneous doping, and stable passivation of the graphene layer. Our study explores the nature of 1/ f noise as a function of carrier density and device geometry and includes data from Hall sensors with device area range spanning over six orders of magnitude, with characteristic device length ranging from L = 1 μm to 1 mm. In optimized graphene Hall sensors, we demonstrate arrays to be a viable route to improve further the magnetic field detection: a simple parallel connection of two devices displays record-high magnetic field sensitivity at room temperature, with minimum detectable magnetic field levels down to B min = 9.5 nT/√Hz. The remarkable low levels of 1/ f noise observed in epigraphene devices hold immense capacity for the design and fabrication of scalable epigraphene-based sensors with exceptional performance. © 2024 Author(s).
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy