1.
  • Morais, Pedro, et al. (författare)
  • Fully automatic left ventricular myocardial strain estimation in 2D short-axis tagged magnetic resonance imaging
  • 2017
  • Ingår i: Physics in Medicine and Biology. - : IOP PUBLISHING LTD. - 0031-9155 .- 1361-6560. ; 62:17, s. 6899-6919
  • Tidskriftsartikel (refereegranskat)abstract
    • Cardiovascular diseases are among the leading causes of death and frequently result in local myocardial dysfunction. Among the numerous imaging modalities available to detect these dysfunctional regions, cardiac deformation imaging through tagged magnetic resonance imaging (t-MRI) has been an attractive approach. Nevertheless, fully automatic analysis of these data sets is still challenging. In this work, we present a fully automatic framework to estimate left ventricular myocardial deformation from t-MRI. This strategy performs automatic myocardial segmentation based on B-spline explicit active surfaces, which are initialized using an annular model. A non-rigid image-registration technique is then used to assess myocardial deformation. Three experiments were set up to validate the proposed framework using a clinical database of 75 patients. First, automatic segmentation accuracy was evaluated by comparing against manual delineations at one specific cardiac phase. The proposed solution showed an average perpendicular distance error of 2.35 +/- 1.21 mm and 2.27 +/- 1.02 mm for the endo- and epicardium, respectively. Second, starting from either manual or automatic segmentation, myocardial tracking was performed and the resulting strain curves were compared. It is shown that the automatic segmentation adds negligible differences during the strain-estimation stage, corroborating its accuracy. Finally, segmental strain was compared with scar tissue extent determined by delay-enhanced MRI. The results proved that both strain components were able to distinguish between normal and infarct regions. Overall, the proposed framework was shown to be accurate, robust, and attractive for clinical practice, as it overcomes several limitations of a manual analysis.
  •  
2.
  • Pedrosa, Joao, et al. (författare)
  • Fast and Fully Automatic Left Ventricular Segmentation and Tracking in Echocardiography Using Shape-Based B-Spline Explicit Active Surfaces
  • 2017
  • Ingår i: IEEE Transactions on Medical Imaging. - : IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. - 0278-0062 .- 1558-254X. ; 36:11, s. 2287-2296
  • Tidskriftsartikel (refereegranskat)abstract
    • Cardiac volume/function assessment remains a critical step in daily cardiology, and 3-D ultrasound plays an increasingly important role. Fully automatic left ventricular segmentation is, however, a challenging task due to the artifacts and low contrast-to-noise ratio of ultrasound imaging. In this paper, a fast and fully automatic framework for the full-cycle endocardial left ventricle segmentation is proposed. This approach couples the advantages of the B-spline explicit active surfaces framework, a purely image information approach, to those of statistical shape models to give prior information about the expected shape for an accurate segmentation. The segmentation is propagated throughout the heart cycle using a localized anatomical affine optical flow. It is shown that this approach not only outperforms other state-of-the-art methods in terms of distance metrics with a mean average distances of 1.81 +/- 0.59 and 1.98 +/- 0.66 mm at end-diastole and end-systole, respectively, but is computationally efficient (in average 11 s per 4-D image) and fully automatic.
  •  
3.
  • Queiros, Sandro, et al. (författare)
  • Multi-centre validation of an automatic algorithm for fast 4D myocardial segmentation in cine CMR datasets
  • 2016
  • Ingår i: European Heart Journal Cardiovascular Imaging. - : OXFORD UNIV PRESS. - 2047-2404 .- 2047-2412. ; 17:10, s. 1118-1127
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims Quantitative analysis of cine cardiac magnetic resonance (CMR) images for the assessment of global left ventricular morphology and function remains a routine task in clinical cardiology practice. To date, this process requires user interaction and therefore prolongs the examination (i.e. cost) and introduces observer variability. In this study, we sought to validate the feasibility, accuracy, and time efficiency of a novel framework for automatic quantification of left ventricular global function in a clinical setting. Methods and results Analyses of 318 CMR studies, acquired at the enrolment of patients in a multi-centre imaging trial (DOPPLER-CIP), were performed automatically, as well as manually. For comparative purposes, intra-and inter-observer variability was also assessed in a subset of patients. The extracted morphological and functional parameters were compared between both analyses, and time efficiency was evaluated. The automatic analysis was feasible in 95% of the cases (302/318) and showed a good agreement with manually derived reference measurements, with small biases and narrow limits of agreement particularly for end-diastolic volume (-4.08 +/- 8.98 mL), end-systolic volume (1.18 +/- 9.74 mL), and ejection fraction (-1.53 +/- 4.93%). These results were comparable with the agreement between two independent observers. A complete automatic analysis took 5.61 +/- 1.22 s, which is nearly 150 times faster than manual contouring (14 +/- 2 min, P amp;lt; 0.05). Conclusion The proposed automatic framework provides a fast, robust, and accurate quantification of relevant left ventricular clinical indices in real-world cine CMR images.
  •  