SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Rödby Kristian) "

Sökning: WFRF:(Rödby Kristian)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Brown, Shannon, et al. (författare)
  • Intarsia-sensorized band and textrodes for real-time myoelectric pattern recognition
  • 2016
  • Ingår i: Engineering in Medicine and Biology Society (EMBC), 2016 IEEE 38th Annual International Conference of the. - : Institute of Electrical and Electronics Engineers (IEEE). - 1557-170X. - 9781457702204 ; , s. 6074-6077
  • Konferensbidrag (refereegranskat)abstract
    • Surface Electromyography (sEMG) has applications in prosthetics, diagnostics and neuromuscular rehabilitation. Self-adhesive Ag/AgCl are the electrodes preferentially used to capture sEMG in short-term studies, however their long-term application is limited. In this study we designed and evaluated a fully integrated smart textile band with electrical connecting tracks knitted with intarsia techniques and knitted textile electrodes. Real-time myoelectric pattern recognition for motor volition and signal-to-noise ratio (SNR) were used to compare its sensing performance versus the conventional Ag-AgCl electrodes. After a comprehending measurement and performance comparison of the sEMG recordings, no significant differences were found between the textile and the Ag-AgCl electrodes in SNR and prediction accuracy obtained from pattern recognition classifiers.
  •  
4.
  • Brown, Shannon, et al. (författare)
  • Intarsia-Sensorized Band and Textrodes for the Acquisition of Myoelectric Signals
  • 2016
  • Ingår i: The Second International Conference on Smart Portable, Wearable, Implantable and Disability-oriented Devices and Systems. - : International Academy, Research and Industry Association (IARIA). - 9781612084800 ; , s. 14-19
  • Konferensbidrag (refereegranskat)abstract
    • Surface Electromyography (sEMG) has applications in prosthetics, diagnostics and neuromuscular rehabilitation, and has been an increasing area of study. This study attempts to use a fully integrated smart textile band with electrical connecting tracks knitted with intarsia techniques to evaluate the quality of sEMG acquired by knitted textile electrodes. Myoelectric pattern recognition for motor volition and signal-to-noise ratio (SNR) were used to compare its sensing performance versus the conventional Ag-AgCl electrodes. Overall no significant differences were found between the textile and the Ag-AgCl electrodes in SNR and prediction accuracy obtained from pattern recognition classifiers. On average the textile electrodes produced a high prediction accuracy, >97% across all movements, which is equivalent to the accuracy obtained with conventional gel electrodes (Ag-AgCl). Furthermore the SNR for the Maximum Voluntary Contraction did not differ considerably between the textile and the Ag-AgCl electrodes.
  •  
5.
  • Gunnarsson, Emanuel, et al. (författare)
  • Seamlessly integrated textile electrodes and conductive routing in a garment for electrostimulation: design, manufacturing and evaluation
  • 2023
  • Ingår i: Scientific Reports. - 2045-2322. ; 13
  • Tidskriftsartikel (refereegranskat)abstract
    • Electro-stimulation to alleviate spasticity, pain and to increase mobility has been used successfully for years. Usually, gelled electrodes are used for this. In a garment intended for repeated use such electrodes must be replaced. The Mollii-suit by the company Inerventions utilises dry conductive rubber electrodes. The electrodes work satisfactory, but the garment is cumbersome to fit on the body. In this paper we show that knitted dry electrodes can be used instead. The knitted electrodes present a lower friction against the skin and a garment is easily fitted to the body. The fabric is stretchable and provides a tight fit to the body ensuring electrical contact. We present three candidate textrodes and show how we choose the one with most favourable features for producing the garment. We validate the performance of the garment by measuring three electrical parameters: rise time (10–90%) of the applied voltage, net injected charge and the low frequency value of the skin–electrode impedance. It is concluded that the use of flat knitting intarsia technique can produce a garment with seamlessly integrated conductive leads and electrodes and that this garment delivers energy to the body as targeted and is beneficial from manufacturing and comfort perspectives.
  •  
6.
  •  
7.
  • Hafid, Abdelakram, et al. (författare)
  • Sensorized T-Shirt with Intarsia-Knitted Conductive Textile Integrated Interconnections: Performance Assessment of Cardiac Measurements during Daily Living Activities
  • 2023
  • Ingår i: Sensors. - 1424-8220. ; 23:22
  • Tidskriftsartikel (refereegranskat)abstract
    • The development of smart wearable solutions for monitoring daily life health status is increasingly popular, with chest straps and wristbands being predominant. This study introduces a novel sensorized T-shirt design with textile electrodes connected via a knitting technique to a Movesense device. We aimed to investigate the impact of stationary and movement actions on electrocardiography (ECG) and heart rate (HR) measurements using our sensorized T-shirt. Various activities of daily living (ADLs), including sitting, standing, walking, and mopping, were evaluated by comparing our T-shirt with a commercial chest strap. Our findings demonstrate measurement equivalence across ADLs, regardless of the sensing approach. By comparing ECG and HR measurements, we gained valuable insights into the influence of physical activity on sensorized T-shirt development for monitoring. Notably, the ECG signals exhibited remarkable similarity between our sensorized T-shirt and the chest strap, with closely aligned HR distributions during both stationary and movement actions. The average mean absolute percentage error was below 3%, affirming the agreement between the two solutions. These findings underscore the robustness and accuracy of our sensorized T-shirt in monitoring ECG and HR during diverse ADLs, emphasizing the significance of considering physical activity in cardiovascular monitoring research and the development of personal health applications. 
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy