SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Röken Bengt) "

Sökning: WFRF:(Röken Bengt)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Nachtigal, Paul E., et al. (författare)
  • Polar bear Ursus maritimus hearing measured with auditory evoked potentials
  • 2007
  • Ingår i: Journal of Experimental Biology. - : The Company of Biologists. - 0022-0949 .- 1477-9145. ; 210, s. 1116-1122
  • Tidskriftsartikel (refereegranskat)abstract
    • While there has been recent concern about the effects of sound on marine mammals, including polar bears, there are no data available measuring the hearing of any bear. The in-air hearing of three polar bears was measured using evoked auditory potentials obtained while tone pips were played to three individually anaesthetized bears at the Kolmården Djurpark. Hearing was tested in half-octave steps from 1 to 22.5 kHz. Measurements were not obtainable at 1 kHz and best sensitivity was found in the range from 11.2–22.5 kHz. Considering the tone pips were short and background noise measurements were available, absolute measurements were estimated based on an assumed mammalian integration time of 300 ms. These data show sensitive hearing in the polar bear over a wide frequency range and should cause those concerned with the introduction of anthropogenic noise into the polar bear's environment to operate with caution.
  •  
2.
  • Nyman, Görel, et al. (författare)
  • Case Studies in Physiology : Ventilation and perfusion in a giraffe-does size matter?
  • 2016
  • Ingår i: Journal of applied physiology. - : American Physiological Society. - 8750-7587 .- 1522-1601. ; 121:6, s. 1374-1378
  • Tidskriftsartikel (refereegranskat)abstract
    • The trachea in the giraffe is long but narrow, and dead space ventilation is considered to be of approximately the same size as in other mammals. Less is known about the matching between ventilation and lung blood flow. The lungs in the giraffe are large, up to 1 m high and 0.7 m wide, and this may cause considerable ventilation/perfusion (V-A/Q) mismatch due to the influence of gravitational forces, which could lead to hypoxemia. We studied a young giraffe under anesthesia using the multiple inert gas elimination technique to analyze the V-A/Q distribution and arterial oxygenation and compared the results with those obtained in other species of different sizes, including humans. V-A/Q distribution was broad but unimodal, and the shunt of blood flow through nonventilated lung regions was essentially absent, suggesting no lung collapse. The V-A/Q match was as good as in the similarly sized horse and was even comparable to that in smaller sized animals, including rabbit and rat. The match was also similar to that in anesthetized humans. Arterial oxygenation was essentially similar in all studied species. The findings suggest that the efficiency of V-A/Q matching is independent of lung size in the studied mammals that vary in weight from less than 1 to more than 400 kg.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy