SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Rafiq Muhammad A.) "

Sökning: WFRF:(Rafiq Muhammad A.)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • 2019
  • Tidskriftsartikel (refereegranskat)
  •  
2.
  • Roberts, Jason D., et al. (författare)
  • Ankyrin-B dysfunction predisposes to arrhythmogenic cardiomyopathy and is amenable to therapy
  • 2019
  • Ingår i: Journal of Clinical Investigation. - : AMER SOC CLINICAL INVESTIGATION INC. - 0021-9738 .- 1558-8238. ; 129:8, s. 3171-3184
  • Tidskriftsartikel (refereegranskat)abstract
    • Arrhythmogenic cardiomyopathy (ACM) is an inherited arrhythmia syndrome characterized by severe structural and electrical cardiac phenotypes, including myocardial fibrofatty replacement and sudden cardiac death. Clinical management of ACM is largely palliative, owing to an absence of therapies that target its underlying pathophysiology, which stems partially from our limited insight into the condition. Following identification of deceased ACM probands possessing ANK2 rare variants and evidence of ankyrin-B loss of function on cardiac tissue analysis, an ANK2 mouse model was found to develop dramatic structural abnormalities reflective of human ACM, including biventricular dilation, reduced ejection fraction, cardiac fibrosis, and premature death. Desmosomal structure and function appeared preserved in diseased human and murine specimens in the presence of markedly abnormal beta-catenin expression and patterning, leading to identification of a previously unknown interaction between ankyrin-B and beta-catenin. A pharmacological activator of the WNT/beta-catenin pathway, SB-216763, successfully prevented and partially reversed the murine ACM phenotypes. Our findings introduce what we believe to be a new pathway for ACM, a role of ankyrin-B in cardiac structure and signaling, a molecular link between ankyrin-B and beta-catenin, and evidence for targeted activation of the WNT/beta-catenin pathway as a potential treatment for this disease.
  •  
3.
  • Batool, S S., et al. (författare)
  • Comparative Analysis of Ti, Ni, and Au Electrodes on Characteristics of TiO2 Nanofibers for Humidity Sensor Application
  • 2013
  • Ingår i: Journal of Materials Science & Technology. - : Elsevier. - 1005-0302. ; 29:5, s. 411-414
  • Tidskriftsartikel (refereegranskat)abstract
    • The effect of metal (Ti, Ni, and Au) electrodes on humidity sensing properties of electrospun TiO2 nanofibers was investigated in this work. The devices were fabricated by evaporating metal contacts on SiO2 layer thermally grown on silicon substrate. The separation between the electrodes was 90 mm for all sensors. The sensors were tested from 40% to 90% relative humidity (RH) by AC electrical characterization at room temperature. When sensors are switched between 40% and 90% RH, the corresponding response and recovery time are 3 s and 5 s for Ti-electrode sensor, 4 s and 7 s for Ni-electrode sensor, and 7 s and 13 s for Au-electrode sensor. The hysteresis was 3%, 5% and 15% for Ti-, Ni-, and Au-electrode sensor, respectively. The sensitivity of Ti, Ni, and Au-electrode sensors are 7.53 M Omega/% RH, 5.29 MU/% RH and 4.01 M Omega/% RH respectively at 100 Hz. Therefore Ti-electrode sensor is found to have linear response, fast response and recovery time and higher sensitivity as compared with those of Ni- and Au-electrode sensors. Comparison of humidity sensing properties of sensors with different electrode material may propose a compelling route for designing and optimizing humidity sensors.
  •  
4.
  • Batool, S S, et al. (författare)
  • Silica nanofibers based impedance type humidity detector prepared on glass substrate
  • 2013
  • Ingår i: Vacuum. - : Elsevier. - 0042-207X .- 1879-2715. ; 87, s. 1-6
  • Tidskriftsartikel (refereegranskat)abstract
    • Impedance type relative humidity detector is fabricated by depositing electrospun silica nanofibers on glass substrate. The silica nanofibers with an average diameter similar to 150 nm and length similar to 100 mu m were used. Thermogravimetric and differential scanning calorimetric analysis confirm that the accurate annealing temperature is 500 degrees C for complete removal of PVP. Humidity detecting devices were fabricated by defining titanium electrodes on top of the silica nanofibers. The performance of silica nanofibers humidity detectors was tested by AC electrical measurements at 40-90% relative humidity. The response and the recovery times were 5 s and 3 s, respectively, between 40% and 90% relative humidity. Contribution of dipoles, space charge polarization, relaxation of these dipoles and low frequency dispersion phenomenon were observed during impedance measurements.
  •  
5.
  • Imran, Z., et al. (författare)
  • Excellent humidity sensing properties of cadmium titanate nanofibers
  • 2013
  • Ingår i: Ceramics International. - : Elsevier. - 0272-8842 .- 1873-3956. ; 39:1, s. 457-462
  • Tidskriftsartikel (refereegranskat)abstract
    • We report humidity sensing characteristics of CdTiO3 nanofibers prepared by electrospinning. The nanofibers were porous having an average diameter and length of similar to 50-200 nm and similar to 100 mu m, respectively. The nanofiber humidity sensor was fabricated by defining aluminum electrodes using photolithography on top of the nanofibers deposited on glass substrate. The performance of the CdTiO3 nanofiber humidity sensor was evaluated by AC electrical characterization from 40% to 90% relative humidity at 25 degrees C. The frequency of the AC signal was varied from 10(-1) to 10(6) Hz. Fast response time and recovery time of 4 s and 6 s were observed, respectively. The sensor was highly sensitive and exhibited a reversible response with small hysteresis of less than 7%. Long term stability of the sensor was confirmed during 30 day test. The excellent sensing characteristics prove that the CdTiO3 nanofibers are potential candidate for use in high performance humidity sensors.
  •  
6.
  • Jamil, Hira, et al. (författare)
  • Electrospun titanium dioxide nanofiber humidity sensors with high sensitivity
  • 2012
  • Ingår i: Ceramics International. - : Elsevier. - 0272-8842 .- 1873-3956. ; 38:3, s. 2437-2441
  • Tidskriftsartikel (refereegranskat)abstract
    • Titanium dioxide nanofibers were synthesized using electrospinning technique. The nanofibers were porous with an average diameter and length of similar to 150 nm and 200 p,m, respectively. Humidity-sensing devices were fabricated by lithographically defined aluminum electrodes on top of the nanofibers deposited on silicon dioxide grown thermally on a silicon substrate. The performance of a TiO2 nanofiber humidity sensor was tested by AC and DC electrical measurements at 40-90% relative humidity. The response and the recovery time were 1 s and 4 s, respectively, between 40% and 90% relative humidity. The sensitivity of the TiO2 humidity sensor in the range of 40-90% RH was 150 M Omega/%RH and 20 M Omega/%RH at 10 Hz and 100 Hz, respectively. The excellent sensing characteristics are attributed to the porous nature and the small diameter of the nanofibers.
  •  
7.
  • Pang, Andy W., et al. (författare)
  • Towards a comprehensive structural variation map of an individual human genome
  • 2010
  • Ingår i: Genome biology. - : Springer Science and Business Media LLC. - 1474-7596 .- 1465-6906. ; 11:5, s. R52-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Several genomes have now been sequenced, with millions of genetic variants annotated. While significant progress has been made in mapping single nucleotide polymorphisms (SNPs) and small (< 10 bp) insertion/deletions (indels), the annotation of larger structural variants has been less comprehensive. It is still unclear to what extent a typical genome differs from the reference assembly, and the analysis of the genomes sequenced to date have shown varying results for copy number variation (CNV) and inversions. Results: We have combined computational re-analysis of existing whole genome sequence data with novel microarray-based analysis, and detect 12,178 structural variants covering 40.6 Mb that were not reported in the initial sequencing of the first published personal genome. We estimate a total non-SNP variation content of 48.8 Mb in a single genome. Our results indicate that this genome differs from the consensus reference sequence by approximately 1.2% when considering indels/CNVs, 0.1% by SNPs and approximately 0.3% by inversions. The structural variants impact 4,867 genes, and >24% of structural variants would not be imputed by SNP-association. Conclusions: Our results indicate that a large number of structural variants have been unreported in the individual genomes published to date. This significant extent and complexity of structural variants, as well as the growing recognition of their medical relevance, necessitate they be actively studied in health-related analyses of personal genomes. The new catalogue of structural variants generated for this genome provides a crucial resource for future comparison studies.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy