  • Hokynar, Kati, et al. (författare)
  • The Finnish New Variant of Chlamydia trachomatis with a Single Nucleotide Polymorphism in the 23S rRNA Target Escapes Detection by the Aptima Combo 2 Test
  • 2019
  • Ingår i: Microorganisms. - : MDPI. - 2076-2607. ; 7:8
  • Tidskriftsartikel (refereegranskat)abstract
    • In 2019, more than 200 cases of Chlamydia trachomatis negative/equivocal by the Aptima Combo 2 assay (AC2, target: 23S rRNA) with slightly elevated relative light units (RLUs), but positive by the Aptima Chlamydia trachomatis assay (ACT, target: 16S rRNA) have been detected in Finland To identify the cause of the AC2 CT false-negative specimens, we sequenced parts of the CT 23S rRNA gene in 40 specimens that were AC2 negative/equivocal but ACT positive. A single nucleotide polymorphism (SNP; C1515T in the C. trachomatis 23S rRNA gene) was revealed in 39 AC2/ACT discordant specimens. No decrease in the number of mandatorily notified C. trachomatis cases was observed nationally in Finland in 2010-2019. When RLUs obtained for AC2 negative specimens were retrospectively evaluated in 2011-2019, a continuous increase in the proportion of samples with RLUs 10-19 was observed since 2014, and a slight increase in the proportion of samples with RLUs 20-84 in 2017-2019, indicating that the Finnish new variant of C. trachomatis might have been spreading nationally for several years. This emphasizes that careful surveillance of epidemiology, positivity rate and test performance are mandatory to detect any changes affecting detection of infections.
  •  
2.
  • Ohlsson, Pelle, et al. (författare)
  • Integrated Acoustic Separation, Enrichment, and Microchip Polymerase Chain Reaction Detection of Bacteria from Blood for Rapid Sepsis Diagnostics
  • 2016
  • Ingår i: Analytical Chemistry. - : American Chemical Society (ACS). - 0003-2700 .- 1520-6882. ; 88:19, s. 9403-9411
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper describes an integrated microsystem for rapid separation, enrichment, and detection of bacteria from blood, addressing the unmet clinical need for rapid sepsis diagnostics. The blood sample is first processed in an acoustophoresis chip, where red blood cells are focused to the center of the channel by an acoustic standing wave and sequentially removed. The bacteria-containing plasma proceeds to a glass capillary with a localized acoustic standing wave field where the bacteria are trapped onto suspended polystyrene particles. The trapped bacteria are subsequently washed while held in the acoustic trap and released into a polymer microchip containing dried polymerase chain reaction (PCR) reagents, followed by thermocycling for target sequence amplification. The entire process is completed in less than 2 h. Testing with Pseudomonas putida spiked into whole blood revealed a detection limit of 1000 bacteria/mL for this first-generation analysis system. In samples from septic patients, the system was able to detect Escherichia coli in half of the cases identified by blood culture. This indicates that the current system detects bacteria in patient samples in the upper part of the of clinically relevant bacteria concentration range and that a further developed acoustic sample preparation system may open the door for a new and faster automated method to diagnose sepsis.
  •  
3.
  • Unemo, Magnus, 1970-, et al. (författare)
  • Sensitivity, specificity, inclusivity and exclusivity of the updated Aptima Combo 2 assay, which provides detection coverage of the new diagnostic-escape Chlamydia trachomatis variants
  • 2020
  • Ingår i: BMC Infectious Diseases. - : BioMed Central. - 1471-2334. ; 20:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Four new variants of Chlamydia trachomatis (nvCTs), detected in several countries, cause false-negative or equivocal results using the Aptima Combo 2 assay (AC2; Hologic). We evaluated the clinical sensitivity and specificity, as well as the analytical inclusivity and exclusivity of the updated AC2 for the detection of CT and Neisseria gonorrhoeae (NG) on the automated Panther system (Hologic).Methods: We examined 1004 clinical AC2 samples and 225 analytical samples spiked with phenotypically and/or genetically diverse NG and CT strains, and other potentially cross-reacting microbial species. The clinical AC2 samples included CT wild type (WT)-positive (n = 488), all four described AC2 diagnostic-escape nvCTs (n = 170), NG-positive (n = 214), and CT/NG-negative (n = 202) specimens.Results: All nvCT-positive samples (100%) and 486 (99.6%) of the CT WT-positive samples were positive in the updated AC2. All NG-positive, CT/NG-negative, Trichomonas vaginalis (TV)-positive, bacterial vaginosis-positive, andCandida-positive AC2 specimens gave correct results. The clinical sensitivity and specificity of the updated AC2 for CT detection was 99.7 and 100%, respectively, and for NG detection was 100% for both. Examining spiked samples, the analytical inclusivity and exclusivity were 100%, i.e., in clinically relevant concentrations of spiked microbe.Conclusions: The updated AC2, including two CT targets and one NG target, showed a high sensitivity, specificity, inclusivity and exclusivity for the detection of CT WT, nvCTs, and NG. The updated AC2 on the fully automated Panther system offers a simple, rapid, high-throughput, sensitive, and specific diagnosis of CT and NG, which can easily be combined with detection of Mycoplasma genitalium and TV.
  •  