SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Riccioni Maria Elena) "

Sökning: WFRF:(Riccioni Maria Elena)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Yung, Diana E., et al. (författare)
  • Capsule endoscopy in young patients with iron deficiency anaemia and negative bidirectional gastrointestinal endoscopy
  • 2017
  • Ingår i: United European Gastroenterology Journal. - : Wiley. - 2050-6406 .- 2050-6414. ; 5:7, s. 974-981
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Recent data imply young patients (age ≤50 years) undergoing small-bowel (SB) capsule endoscopy (CE) for iron deficiency anaemia (IDA) show higher diagnostic yield (DY) for sinister pathology. We aimed to investigate DY of CE in a large cohort of young IDA patients, and evaluate factors predicting significant SB pathology. Materials and methods: This was a retrospective, multicentre study (2010–2015) in consecutive, young patients (≤50 years) from 18 centres/12 countries, with negative bidirectional gastrointestinal (GI) endoscopy undergoing SBCE for IDA. Exclusion criteria: previous/ongoing obscure-overt GI bleeding; age <19 or >50 years; comorbidities associated with IDA. Data retrieved: SBCE indications; prior investigations; medications; SBCE findings; final diagnosis. Clinical and laboratory data were analysed by multivariate logistic regression. Results: Data on 389 young IDA patients were retrieved. In total, 169 (43.4%) were excluded due to incomplete clinical data; data from 220 (122F/98M; mean age 40.5 ± 8.6 years) patients were analysed. Some 71 patients had at least one clinically significant SBCE finding (DY: 32.3%). They were divided into two groups: neoplastic pathology (10/220; 4.5%), and non-neoplastic but clinically significant pathology (61/220; 27.7%). The most common significant but non-neoplastic pathologies were angioectasias (22/61) and Crohn’s disease (15/61). On multivariate analysis, weight loss and lower mean corpuscular volume(MCV) were associated with significant SB pathology (OR: 3.87; 95%CI: 1.3–11.3; p = 0.01; and OR: 0.96; 95%CI: 0.92–0.99; p = 0.03; respectively). Our model also demonstrates association between use of antiplatelets and significant SB pathology, although due to the small number of patients, definitive conclusions cannot be drawn. Conclusion: In IDA patients ≤50 years with negative bidirectional GI endoscopy, overall DY of SBCE for clinically significant findings was 32.3%. Some 5% of our cohort was diagnosed with SB neoplasia; lower MCV or weight loss were associated with higher DY for SB pathology.
  •  
2.
  • Baltes, Peter, et al. (författare)
  • Small-bowel capsule endoscopy in patients with Meckel's diverticulum : clinical features, diagnostic workup, and findings. A European multicenter I-CARE study
  • 2023
  • Ingår i: Gastrointestinal Endoscopy. - : Elsevier BV. - 0016-5107. ; 97:5, s. 3-926
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and Aims: Meckel's diverticulum (MD) may remain silent or be associated with adverse events such as GI bleeding. The main aim of this study was to evaluate indicative small-bowel capsule endoscopy (SBCE) findings, and the secondary aim was to describe clinical presentation in patients with MD. Methods: This retrospective European multicenter study included patients with MD undergoing SBCE from 2001 until July 2021. Results: Sixty-nine patients with a confirmed MD were included. Median age was 32 years with a male-to-female ratio of approximately 3:1. GI bleeding or iron-deficiency anemia was present in nearly all patients. Mean hemoglobin was 7.63 ± 1.8 g/dL with a transfusion requirement of 52.2%. Typical capsule endoscopy (CE) findings were double lumen (n = 49 [71%]), visible entrance into the MD (n = 49 [71%]), mucosal webs (n = 30 [43.5%]), and bulges (n = 19 [27.5%]). Two or more of these findings were seen in 48 patients (69.6%). Ulcers were detected in 52.2% of patients (n = 36). In 63.8% of patients (n = 44), a combination of double lumen and visible entrance into the MD was evident, additionally revealing ulcers in 39.1% (n = 27). Mean percent SB (small bowel) transit time for the first indicative image of MD was 57% of the total SB transit time. Conclusions: Diagnosis of MD is rare and sometimes challenging, and a preoperative criterion standard does not exist. In SBCE, the most frequent findings were double-lumen sign and visible diverticular entrance, sometimes together with ulcers.
  •  
3.
  • Dray, Xavier, et al. (författare)
  • Feasibility and diagnostic yield of small-bowel capsule endoscopy in patients with surgically altered gastric anatomy : the SAGA study
  • 2021
  • Ingår i: Gastrointestinal Endoscopy. - : Elsevier BV. - 0016-5107. ; 94:3, s. 1-597
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and Aims: Little is known about small-bowel (SB) capsule endoscopy (CE) in patients with a history of gastric surgery. This study aims to evaluate the feasibility and diagnostic yield (DY) of orally ingested SB-CE in patients with surgically altered gastric anatomy. Methods: Twenty-four European centers retrospectively identified patients who had SB-CE after total or subtotal gastrectomy. The primary outcome was the DY of SB-CE (intermediate P1 to highly P2 relevant findings). Secondary outcomes were gastric and SB transit times, completion, cleanliness, and adverse event rates. Results: Studied were 248 procedures from 243 patients (mean age, 62 years) with a history of partial gastrectomy (Billroth I, 13.1%; Billroth II, 34.6%), total gastrectomy (7.4%), Whipple procedure (12.8%), sleeve gastrectomy (7.2%), or gastric bypass surgery (24.7%). Obscure GI bleeding was the most frequent indication (85.1%). SB completion rate was 84.3%. One capsule retention in the SB was noted (adverse event rate,.4%). Median SB transit time was 286 minutes (interquartile range [235; 387]). Cleanliness was rated as adequate in 92.1% of procedures. After exclusion of abnormalities found at the upper anastomotic site, the DY was 43.6%, with inflammatory/ulcerated lesions observed more frequently (23.4%) than vascular lesions (21.0%). Conclusions: SB-CE seems to be feasible and safe in selected patients with a history of major gastric surgery and comes with a high DY. The spectrum of abnormal SB findings in these patients may be different from what is known from the literature in nonoperated patients.
  •  
4.
  • Dray, Xavier, et al. (författare)
  • Small bowel capsule endoscopy in obscure gastrointestinal bleeding : A matched cohort comparison of patients with normal vs surgically altered gastric anatomy
  • 2022
  • Ingår i: Clinics and Research in Hepatology and Gastroenterology. - : Elsevier BV. - 2210-7401. ; 46:7
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Little is known about small bowel capsule endoscopy (SBCE) outcomes in patients with surgically altered anatomy. Aims: To assess the feasibility and diagnostic yield of orally ingested SBCE to investigate obscure gastrointestinal bleeding (OGIB) in patients with surgically altered gastric anatomy, compared to native gastric anatomy. Methods: 207 patients with OGIB were selected from an open, multicenter, retrospective cohort (SAGA study) and match-paired according to age, gender and bleeding type (overt/occult) to 207 control patients from a randomized controlled trial (PREPINTEST). Primary outcomes were the diagnostic yield (P1 or P2 findings), completion rate, adverse events rate, and small bowel transit time (SBTT). Results: The diagnostic yield was not statistically different between groups (44.9% in SAGA vs 42.5% in control patients). Inflammatory/ulcerated lesions were significantly more frequent in patients with SAGA (43.0% vs 29.3%). The median SBTT was significantly longer in the SAGA group than in control patients (283 vs 206 minutes), with a significantly lower completion rate (82.6% vs 89.9%); Adverse events were scarce (0.5% vs 0.0%). Conclusion: Patients with surgically altered gastric anatomy should benefit from SBCE investigation for OGIB as much as non-operated patients.
  •  
5.
  • Elli, Luca, et al. (författare)
  • Nomenclature and Definition of Atrophic Lesions in Small Bowel Capsule Endoscopy : A Delphi Consensus Statement of the International CApsule endoscopy REsearch (I-CARE) Group
  • 2022
  • Ingår i: Diagnostics. - : MDPI AG. - 2075-4418. ; 12:7
  • Tidskriftsartikel (refereegranskat)abstract
    • (1) Background: Villous atrophy is an indication for small bowel capsule endoscopy (SBCE). However, SBCE findings are not described uniformly and atrophic features are sometimes not recognized; (2) Methods: The Delphi technique was employed to reach agreement among a panel of SBCE experts. The nomenclature and definitions of SBCE lesions suggesting the presence of atrophy were decided in a core group of 10 experts. Four images of each lesion were chosen from a large SBCE database and agreement on the correspondence between the picture and the definition was evaluated using the Delphi method in a broadened group of 36 experts. All images corresponded to histologically proven mucosal atrophy; (3) Results: Four types of atrophic lesions were identified: mosaicism, scalloping, folds reduction, and granular mucosa. The core group succeeded in reaching agreement on the nomenclature and the descriptions of these items. Consensus in matching the agreed definitions for the proposed set of images was met for mosaicism (88.9% in the first round), scalloping (97.2% in the first round), and folds reduction (94.4% in the first round), but granular mucosa failed to achieve consensus (75.0% in the third round); (4) Conclusions: Consensus among SBCE experts on atrophic lesions was met for the first time. Mosaicism, scalloping, and folds reduction are the most reliable signs, while the description of granular mucosa remains uncertain.
  •  
6.
  • Spada, Cristiano, et al. (författare)
  • AI-assisted capsule endoscopy reading in suspected small bowel bleeding : a multicentre prospective study
  • 2024
  • Ingår i: The Lancet Digital Health. - 2589-7500. ; 6:5, s. 345-353
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Capsule endoscopy reading is time consuming, and readers are required to maintain attention so as not to miss significant findings. Deep convolutional neural networks can recognise relevant findings, possibly exceeding human performances and reducing the reading time of capsule endoscopy. Our primary aim was to assess the non-inferiority of artificial intelligence (AI)-assisted reading versus standard reading for potentially small bowel bleeding lesions (high P2, moderate P1; Saurin classification) at per-patient analysis. The mean reading time in both reading modalities was evaluated among the secondary endpoints. Methods: Patients aged 18 years or older with suspected small bowel bleeding (with anaemia with or without melena or haematochezia, and negative bidirectional endoscopy) were prospectively enrolled at 14 European centres. Patients underwent small bowel capsule endoscopy with the Navicam SB system (Ankon, China), which is provided with a deep neural network-based AI system (ProScan) for automatic detection of lesions. Initial reading was performed in standard reading mode. Second blinded reading was performed with AI assistance (the AI operated a first-automated reading, and only AI-selected images were assessed by human readers). The primary endpoint was to assess the non-inferiority of AI-assisted reading versus standard reading in the detection (diagnostic yield) of potentially small bowel bleeding P1 and P2 lesions in a per-patient analysis. This study is registered with ClinicalTrials.gov, NCT04821349. Findings: From Feb 17, 2021 to Dec 29, 2021, 137 patients were prospectively enrolled. 133 patients were included in the final analysis (73 [55%] female, mean age 66·5 years [SD 14·4]; 112 [84%] completed capsule endoscopy). At per-patient analysis, the diagnostic yield of P1 and P2 lesions in AI-assisted reading (98 [73·7%] of 133 lesions) was non-inferior (p<0·0001) and superior (p=0·0213) to standard reading (82 [62·4%] of 133; 95% CI 3·6–19·0). Mean small bowel reading time was 33·7 min (SD 22·9) in standard reading and 3·8 min (3·3) in AI-assisted reading (p<0·0001). Interpretation: AI-assisted reading might provide more accurate and faster detection of clinically relevant small bowel bleeding lesions than standard reading. Funding: ANKON Technologies, China and AnX Robotica, USA provided the NaviCam SB system.
  •  
7.
  • Spada, Cristiano, et al. (författare)
  • Second-generation colon capsule endoscopy compared with colonoscopy
  • 2011
  • Ingår i: Gastrointestinal Endoscopy. - : Elsevier BV. - 1097-6779 .- 0016-5107. ; 74:3, s. 581-589
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Colon capsule endoscopy (CCE) represents a noninvasive technology that allows visualization of the colon without requiring sedation and air insufflation. A second-generation colon capsule endoscopy system (PillCam Colon 2) (CCE-2) was developed to increase sensitivity for colorectal polyp detection compared with the first-generation system. Objective: To assess the feasibility, accuracy, and safety of CCE-2 in a head-to-head comparison with colonoscopy. Design and Setting: Prospective, multicenter trial including 8 European sites. Patients: This study involved 117 patients (mean age 60 years). Data from 109 patients were analyzed. Intervention: CCE-2 was prospectively compared with conventional colonoscopy as the criterion standard for the detection of colorectal polyps that are >= 6 mm or masses in a cohort of patients at average or increased risk of colorectal neoplasia. Colonoscopy was independently performed within 10 hours after capsule ingestion or on the next day. Main Outcome Measurements: CCE-2 sensitivity and specificity for detecting patients with polyps >= 6 mm and >= 10 mm were assessed. Capsule-positive but colonoscopy-negative cases were counted as false positive. Capsule excretion rate, level of bowel preparation, and rate of adverse events also were assessed. Results: Per-patient CCE-2 sensitivity for polyps >= 6 mm and >= 10 mm was 84% and 88%, with specificities of 64% and 95%, respectively. All 3 invasive carcinomas were detected by CCE-2. The capsule excretion rate was 88% within 10 hours. Overall colon cleanliness for CCE-2 was adequate in 81% of patients. Limitations: Not unblinding the CCE-2 results at colonoscopy; heterogenous patient population; nonconsecutive patients. Conclusion: In this European, multicenter study, CCE-2 appeared to have a high sensitivity for the detection of clinically relevant polypoicl lesions, and it might be considered an adequate tool for colorectal imaging. (Gastrointest Enclose 201174:581-9.)
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy