SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Rohlffs Fiona) "

Sökning: WFRF:(Rohlffs Fiona)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Berczeli, Márton, et al. (författare)
  • Multicentre Experience with Novel Bidirectional Double Cuffed Inner Branches for Complex Endovascular Aortic Repair
  • 2024
  • Ingår i: European journal of vascular and endovascular surgery. - 1078-5884.
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: This study aimed to report the initial experience with a novel bidirectional double cuff inner branch design for incorporation of renal and mesenteric arteries in patients undergoing fenestrated and branched endovascular aortic repair (F/BEVAR). Methods: A retrospective review was undertaken of the experience of F/BEVAR with grafts integrating at least one bidirectional double cuffed inner branch implanted at three tertiary aortic centres between March 2022 and June 2023. All consecutive patients were included. Baseline characteristics, operative data, and follow up data were collected. Results were presented as number or median (interquartile range) unless otherwise stated. Results: Thirteen patients (10 male; median age 72 [68, 77] years) had F/BEVAR using a total of 15 bidirectional double cuffed inner branches (30 cuffs). Indications for bidirectional doubled cuffed inner branches included cranial vessel orientation or double renal arteries in four patients each, common coeliomesenteric trunk in three patients, and early renal artery bifurcation, renal artery origin from a false lumen requiring a flexible route for catheterisation, and surplus configuration in one patient each. Twenty three of the 30 cuffs were used, whereas the remaining seven cuffs were intentionally occluded with vascular plugs. Target vessel incorporation was successful in all bidirectional branches. There was one technical failure related to unsuccessful catheterisation of a left renal artery targeted through a unidirectional caudal inner branch. During a median follow up of seven months there were no instances of target vessel instability or re-interventions and two patients died of causes unrelated to the bidirectional branches. Conclusion: The results of the use of bidirectional double cuff inner branches are promising, with high technical success and no short term branch related complications in this preliminary experience. This could potentially expand the applicability of branch endografting of complex endovascular aortic repairs, but long term results are still missing.
  •  
2.
  • Budtz-Lilly, Jacob, et al. (författare)
  • European Multicentric Experience With Fenestrated-branched ENDOvascular Stent Grafting After Previous FAILed Infrarenal Aortic Repair The EU-FBENDO-FAIL Registry
  • 2023
  • Ingår i: Annals of Surgery. - : Ovid Technologies (Wolters Kluwer Health). - 0003-4932 .- 1528-1140. ; 278:2, s. E389-E395
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective:To report the mid-term outcomes of fenestrated-branched endovascular aneurysm repair (F-BEVAR) following a failed previous endovascular aneurysm repair (pEVAR) or previous open aneurysm repair (pOAR).Methods:Data from consecutive patients who underwent F-BEVAR for pEVAR or pOAR from 2006 to 2021 from 17 European vascular centers were analyzed. Endpoints included technical success, major adverse events, 30-day mortality, and 5-year estimates of survival, target vessel primary patency, freedom from reinterventions, type I/III endoleaks, and sac growth >5 mm.Background:Treatment of a failed previous abdominal aortic aneurysm repair is a complex undertaking. F-BEVAR is becoming an increasingly attractive option, although comparative data are limited regarding associated risk factors, indications for treatment, and various outcomes.Results:There were 526 patients included, 268 pOAR and 258 pEVAR. The median time from previous repair to F-BEVAR was 7 (interquartile range, 4-12) years, 5 (3-8) for pEVAR, and 10 (6-14) for pOAR, P<0.001. Predominant indication for treatment was type Ia endoleak for pEVAR and progression of the disease for pOAR. Technical success was 92.8%, pOAR (92.2%), and pEVAR (93.4%), P=0.58. The 30-day mortality was 6.5% overall, 6.7% for pOAR, and 6.2% for pEVAR, P=0.81. There were 1853 treated target vessels with 5-year estimates of primary patency of 94.4%, pEVAR (95.2%), and pOAR (94.4%), P=0.03. Five-year estimates for freedom from type I/III endoleaks were similar between groups; freedom from reintervention was lower for pEVAR (38.3%) than for pOAR (56.0%), P=0.004. The most common indication for reinterventions was for type I/III endoleaks (37.5%).Conclusions:Repair of a failed pEVAR or pOARis safe and feasible with comparable technical success and survival rates. While successful treatment can be achieved, significant rates of reintervention should be anticipated, particularly for issues related to instability of target vessels/bridging stents.
  •  
3.
  • Dias, N., et al. (författare)
  • Outcomes of Elective and Non-elective Fenestrated-branched Endovascular Aortic Repair for Treatment of Thoracoabdominal Aortic Aneurysms
  • 2023
  • Ingår i: Annals of Surgery. - : Lippincott Williams & Wilkins. - 0003-4932 .- 1528-1140. ; 278:4, s. 568-577, s. 568-577
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: To describe outcomes after elective and non-elective fenestrated-branched endovascular aortic repair (FB-EVAR) for thoracoabdominal aortic aneurysms (TAAAs).Background: FB-EVAR has been increasingly utilized to treat TAAAs; however, outcomes after non-elective versus elective repair are not well described.Methods: Clinical data of consecutive patients undergoing FB-EVAR for TAAAs at 24 centers (2006-2021) were reviewed. Endpoints including early mortality and major adverse events (MAEs), all-cause mortality, and aortic-related mortality (ARM), were analyzed and compared in patients who had non-elective versus elective repair.Results: A total of 2603 patients (69% males; mean age 72 +/- 10 year old) underwent FB-EVAR for TAAAs. Elective repair was performed in 2187 patients (84%) and non-elective repair in 416 patients [16%; 268 (64%) symptomatic, 148 (36%) ruptured]. Non-elective FB-EVAR was associated with higher early mortality (17% vs 5%, P < 0.001) and rates of MAEs (34% vs 20%, P < 0.001). Median follow-up was 15 months ( interquartile range, 7-37 months). Survival and cumulative incidence of ARM at 3 years were both lower for non-elective versus elective patients (50 +/- 4% vs 70 +/- 1% and 21 +/- 3% vs 7 +/- 1%, P < 0.001). On multivariable analysis, non-elective repair was associated with increased risk of all-cause mortality ( hazard ratio, 1.92; 95% CI] 1.50-2.44; P < 0.001) and ARM (hazard ratio, 2.43; 95% CI, 1.63-3.62; P < 0.001).Conclusions: Non-elective FB-EVAR of symptomatic or ruptured TAAAs is feasible, but carries higher incidence of early MAEs and increased all-cause mortality and ARM than elective repair. Long-term follow-up is warranted to justify the treatment.
  •  
4.
  • Dias-Neto, Marina, et al. (författare)
  • Comparison of single- and multistage strategies during fenestrated-branched endovascular aortic repair of thoracoabdominal aortic aneurysms
  • 2023
  • Ingår i: Journal of Vascular Surgery. - : MOSBY-ELSEVIER. - 0741-5214 .- 1097-6809. ; 77:6, s. 1588-1597
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: The aim of this study was to compare outcomes of single or multistage approach during fenestrated-branched endovascular aortic repair (FB-EVAR) of extensive thoracoabdominal aortic aneurysms (TAAAs).Methods: We reviewed the clinical data of consecutive patients treated by FB-EVAR for extent I to III TAAAs in 24 centers (2006-2021). All patients received a single brand manufactured patient-specific or off-the-shelf fenestrated-branched stent grafts. Staging strategies included proximal thoracic aortic repair, minimally invasive segmental artery coil embolization, temporary aneurysm sac perfusion and combinations of these techniques. Endpoints were analyzed for elective repair in patients who had a single-or multistage approach before and after propensity score adjustment for baseline differences, including the composite 30-day/in-hospital mortality and/or permanent paraplegia, major adverse event, patient survival, and freedom from aortic-related mortality.Results: A total of 1947 patients (65% male; mean age, 71 +/- 8 years) underwent FB-EVAR of 155 extent I (10%), 729 extent II (46%), and 713 extent III TAAAs (44%). A single-stage approach was used in 939 patients (48%) and a multistage approach in 1008 patients (52%). A multistage approach was more frequently used in patients undergoing elective compared with non-elective repair (55% vs 35%; P < .001). Staging strategies were proximal thoracic aortic repair in 743 patients (74%), temporary aneurysm sac perfusion in 128 (13%), minimally invasive segmental artery coil embolization in 10 (1%), and combinations in 127 (12%). Among patients undergoing elective repair (n = 1597), the composite endpoint of 30-day/in-hospital mortality and/or permanent paraplegia rate occurred in 14% of single-stage and 6% of multistage approach patients (P < .001). After adjustment with a propensity score, multistage approach was associated with lower rates of 30-day/in-hospital mortality and/or permanent paraplegia (odds ratio, 0.466; 95% confidence interval, 0.271-0.801; P = .006) and higher patient survival at 1 year (86.9 +/- 1.3% vs 79.6 +/- 1.7%) and 3 years (72.7 +/- 2.1% vs 64.2 +/- 2.3%; adjusted hazard ratio, 0.714; 95% confidence interval, 0.528-0.966; P = .029), compared with a single stage approach.Conclusions: Staging elective FB-EVAR of extent I to III TAAAs was associated with decreased risk of mortality and/or permanent paraplegia at 30 days or within hospital stay, and with higher patient survival at 1 and 3 years.
  •  
5.
  • Koelbel, Tilo, et al. (författare)
  • Fenestrated TEVAR Using a Guidewire Fixator for Anchoring in Aortic Arch Target Vessels
  • 2018
  • Ingår i: Journal of Endovascular Therapy. - : SAGE Publications. - 1526-6028 .- 1545-1550. ; 25:1, s. 40-46
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose:To report a new facilitated method for securing target vessel access during single fenestrated and branched thoracic endovascular repair using a guidewire fixator.Technique: The Liungman Guidewire Fixator (LGF) includes a 0.035-inch guidewire that is fitted with a stopper close to the distal end and a self-expanding anchoring element that is freely movable over the guidewire to the point of the stopper. The technique of using a LGF for anchoring in a target vessel is described in a 75-year-old woman with a 53-mm saccular arch aneurysm. She was treated with a fenestrated Zenith stent-graft that had a catheter-preloaded fenestration for the left subclavian artery (LSA) and a scallop for the left common carotid artery. To avoid through-and-through wire and brachial access, the LGF was used to secure the guidewire in the LSA during stent-graft deployment.Conclusion: The use of an LGF for anchoring in the target LSA during fenestrated arch endografting was feasible and safe.
  •  
6.
  • Koelbel, Tilo, et al. (författare)
  • Physician-Modified Thoracic Stent-Graft With Low Distal Radial Force to Prevent Distal Stent-Graft-Induced New Entry Tears in Patients With Genetic Aortic Syndromes and Aortic Dissection
  • 2018
  • Ingår i: Journal of Endovascular Therapy. - : SAGE Publications. - 1526-6028 .- 1545-1550. ; 25:4, s. 456-463
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To describe a novel modification technique to lower the distal radial force of a thoracic stent-graft so as to avert stent-graft-induced new entry tears (SINE) in the fragile aorta of patients with genetic aortic disease and aortic dissection. Technique: A commercially available thoracic stent-graft is partially deployed on a back table. The most distal Z-stent is removed, the distal fabric is marked by vascular clips, and the modified stent-graft is reloaded and deployed in the true lumen of an aortic dissection. The technique is demonstrated in 3 patients with aortic dissection related to genetic aortic diseases. Conclusion: Creating a low distal radial force stent-graft is easy and can be done in a short time. Endovascular implantation appears feasible and safe.
  •  
7.
  • Tsilimparis, Nikolaos, et al. (författare)
  • Pre-Loaded Fenestrated Thoracic Endografts for Distal Aortic Arch Pathologies : Multicentre Retrospective Analysis of Short and Mid Term Outcomes
  • 2021
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Saunders Elsevier. - 1078-5884 .- 1532-2165. ; 62:6, s. 887-895
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: To determine short and midterm outcomes of a pre-loaded fenestrated thoracic endograft (f-TEVAR) for exclusion of distal aortic arch pathologies.Methods: This was a multicentre, retrospective study including consecutive patients from six experienced European vascular centres undergoing f-TEVAR for distal arch pathologies. Primary endpoints included peri-operative mortality and peri-operative stroke and/or spinal cord ischaemia rates. Secondary outcomes were technical success and mid to late events, including death and re-interventions. Statistical analysis was performed with SPSS 26. Mid to late term events were calculated using Kaplan–Meier survival analysis.Results: One hundred and eight patients were included (mean age 68 ± 11 years, 70% men). A total of 38% (n = 42) had a prior history of aortic dissection, and 24% (n = 26) prior aortic surgery. The mean aneurysm diameter was 59 ± 12 mm and the most frequent indication for treatment was post-dissection aneurysms (n = 42, 39%). Technical success was 99% (n = 107) despite intra-operative wire entanglement occurring in 29% (n = 31). The 30 day mortality rate was 3.7% (n = 4), with a 5.6% major stroke incidence (n = 6) and 3.7% (n = 4) spinal cord ischaemia rate. Three cases of retrograde dissection occurred (two of which were fatal), all in post-type B dissecting aneurysm patients without prior aortic surgery (three of 19, 15.8%). Median follow up was 12 months (range, 1 – 26). Endoleaks were documented during follow up, with 3.5% type Ia (4/104) and 2.9% type Ib (3/104) as a result of persistent false lumen perfusion. The one, two, and three year survivals and freedom from re-intervention rates were 93.2% and 92.1%, 89.1% and 86.3%, and 84.4% and 73%, respectively.Conclusion: This multicentre study shows that treatment of the distal aortic arch by f-TEVAR is feasible, with promising 30 day mortality, stroke, and spinal cord ischaemia rates.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy