SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Roijer Anders) "

Sökning: WFRF:(Roijer Anders)

  • Resultat 1-10 av 62
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Olsson, Bertil, et al. (författare)
  • Förmaksflimmer - ny kunskap ger nya behandlingsmöjligheter
  • 1999
  • Ingår i: Läkartidningen. - 0023-7205. ; 96:36, s. 3796-3803
  • Tidskriftsartikel (refereegranskat)abstract
    • Atrial fibrillation (AF) is the most common cardiac arrhythmia prompting treatment. Advances in our knowledge of the pathophysiology of AF provide the basis for new and improved treatment modalities. Thus, focal excitation and localised impulse conduction defects are possible trigger factors which can be counteracted by focal ablation and pacing synchronisation, respectively. Perpetuation of AF, caused by continuous multisite re-entry, is promoted by successive shortening of repolarisation. Internal defibrillation and anatomical limitation of re-entry are treatments that counteract perpetuation of the arrhythmia. Current knowledge of AF and the application of new treatments are discussed by the Lund AF research group.
  •  
2.
  • Al-Rashidi, Faleh, et al. (författare)
  • A new de-airing technique that reduces systemic microemboli during open surgery: a prospective controlled study.
  • 2009
  • Ingår i: The Journal of thoracic and cardiovascular surgery. - : Elsevier BV. - 1097-685X .- 0022-5223. ; 138:1, s. 157-162
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: We have evaluated a new technique of cardiac de-airing that is aimed at a) minimizing air from entering into the pulmonary veins by opening both pleurae and allowing lungs to collapse and b) flushing out residual air from the lungs by staged cardiac filling and lung ventilation. These air emboli are usually trapped in the pulmonary veins and may lead to ventricular dysfunction, life-threatening arrhythmias, and transient or permanent neurologic deficits. METHODS: Twenty patients undergoing elective true left open surgery were prospectively and alternately enrolled in the study to the conventional de-airing technique (pleural cavities unopened, dead space ventilation during cardiopulmonary bypass [control group]) and the new de-airing technique (pleural cavities open, ventilator disconnected during cardiopulmonary bypass, staged perfusion, and ventilation of lungs during de-airing [study group]). Transesophageal echocardiography and transcranial Doppler continually monitored the air emboli during the de-airing period and for 10 minutes after termination of the cardiopulmonary bypass. RESULTS: The amount of air embolism as observed on echocardiography and the number of microembolic signals as recorded by transcranial Doppler were significantly less in the study group during the de-airing time (P < .001) and the first 10 minutes after termination of cardiopulmonary bypass (P < .001). Further, the de-airing time was significantly shorter in the study group (10 vs 17 minutes, P < .001). CONCLUSION: The de-airing technique evaluated in this study is simple, reproducible, controlled, safe, and effective. Moreover, it is cost-effective because the de-airing time is short and no extra expenses are involved.
  •  
3.
  • Al Rashidi, Faleh, et al. (författare)
  • The modified Ross operation using a Dacron prosthetic vascular jacket does prevent pulmonary autograft dilatation at 4.5-year follow-up.
  • 2010
  • Ingår i: European Journal of Cardio-Thoracic Surgery. - : Oxford University Press (OUP). - 1010-7940. ; 37, s. 928-933
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: Following the Ross operation, pulmonary autografts tend to dilate over time. This study researches the fate of the pulmonary autograft - at 4.5 years following the modified Ross operation - with special reference to the impact of the modification on (a) pulmonary autograft dilatation, (b) the neo-aortic root geometry, (c) neo-aortic valve function and (d) the coronary artery reserve. Methods: A total of 26 patients who underwent the Ross operation were included in this study; of these, 13 consecutive patients underwent a modified Ross operation in which the free-standing autograft root was supported externally by a Dacron vascular prosthetic jacket (DVPJ). These patients were compared to a cohort of 13 matched patients who were operated on using the conventional Ross technique; all patients were followed up prospectively by echocardiography studies. The patients who underwent the modified Ross operation were also subjected to bicycle ergometry. Results: At the 47-month median follow-up, there was no significant increase in the size of the entire neo-aortic root in the patients who underwent the modified Ross operation; in addition, the geometry of the neo-aortic root was also preserved and the left ventricular function had improved significantly, whilst the aortic valve function and excursion remained satisfactory. All patients, with one exception, in the modified Ross operation group exhibited normal exercise capacity. By contrast, there were significant differences in diameters of the aortic root - between the two surgical techniques in favour of the modified Ross technique - following a median follow-up of 23 months in the patients subjected to the conventional Ross operation. Conclusions: Provision of external support to the entire pulmonary autograft with a DVPJ prevents its dilatation following free-standing pulmonary autograft Ross operation when evaluated at the 4.5-year follow-up. The function and the geometry of the neo-aortic root are not affected negatively by this modification and the patients demonstrated normal exercise capacity.
  •  
4.
  •  
5.
  • Bakos, Zoltan, et al. (författare)
  • Cardiovascular drug utilization post-implant is related to clinical outcome in heart failure patients receiving cardiac resynchronization therapy
  • 2017
  • Ingår i: Cardiology Journal. - 1898-018X. ; 24:4, s. 374-384
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: In select patients with heart failure, cardiac resynchronization therapy (CRT) is the most common complementary treatment besides medical treatment. We aimed to assess the association between post CRT-implant changes in cardiovascular medication and cardiovascular mortality and heart failure hospitalization.METHODS: 211 patients on optimal medical therapy eligible for CRT were retrospectively included in this study (72 ± 7 years, 80% male, 66% left bundle branch block [LBBB], 48% dilated cardiomyopathy [DCMP]) and investigated at baseline and after 6 months . Follow-up with medication, biochemical markers and echocardiography was performed and 3-year mortality data was collected.RESULTS: At 6 months post-implant the cohort was divided into two groups; 157 patients had low dosage furosemide treatment (up to 40 mg) and 54 patients were treated with high dosage (> 40 mg). A composite endpoint of heart failure hospitalization and all-cause mortality was evaluated at 30 months (881 ± 267 days) after the 6-month visit. In multivariate Cox regression analysis, patients in the high dose diuretics group had a higher risk of the primary endpoint (HR 1.9 [1.1-3.4], p = 0.033), but treatment with high dose diuretics was not associated with improved clinical symptoms (r = 0.031, p = 0.64).CONCLUSIONS: High dosage of loop-diuretics was associated with worse medium-term clinical outcome in CRT treated patients. It is unclear whether there is a direct causality between these associations, or if higher prescribed dosage of loop-diuretics is just a marker of more severe disease. Higher dose loop diuretics do not necessarily improve the symptoms and may be harmful to the patient. Prospective trials are warranted to further elucidate these findings.
  •  
6.
  •  
7.
  • BAKOS, ZOLTAN, et al. (författare)
  • Positive Response to Cardiac Resynchronization Therapy : The Role of NT-proBNP
  • 2016
  • Ingår i: International journal of cardiovascular research. - : OMICS Publishing Group. - 2324-8602. ; 5:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Abstract Background: Cardiac resynchronization therapy (CRT) is effective, but only 60-70% of patients benefit from the therapy. Despite numerous implantations, identification of predictive factors for response is still a challenge. We sought to assess the correlation of echocardiographic and clinical response to baseline demographics in relation to change in NT-proBNP levels at 6 months. Methods: 211 patients on optimal medical therapy were included retrospectively (72 ± 10 yrs., 66% LBBB, 48% DCMP, 80% male) and investigated at baseline and 6 months later. Improvement of ≥ 1 NYHA class was used as a marker for clinical response, and >15% reduction of left ventricular end-systolic volume was used to de ne reverse remodeling. NT-proBNP levels were measured at baseline and at 6 months and were compared to echocardiographic and clinical response status.Results: Four groups were identi ed: 1) non-responder, 2) echo responder, 3) clinical responder, and 4) double responder (echo and clinical). Responders were younger (70 vs. 74 years, p=0.04), had better NYHA class (2.1 vs. 2.5, p=0.01) and had lower NT- proBNP compared to non-responders at baseline. NT-proBNP slightly increased or remained unchanged in non-responders, whereas reduction in NT-proBNP was of similar magnitude for clinical or echo responders, and was most pronounced for double responders. A reduction of NT-proBNP ≥25% separated non- responders from responders (p=0.01). No signi cant differences in NT-proBNP levels and no signi cant changes in NT-proBNP were found across the responder subgroups.Conclusion: Six-month reduction in NT-proBNP is most pronounced for “double responders, ” but was comparable in patients with either clinical or echo response. Lack of NT-proBNP reduction can help identify the non-responders for further intervention.Keywords Cardiac resynchronization therapy; Electrocardiography; Echocardiography
  •  
8.
  • Bollmann, Andreas, et al. (författare)
  • Atrial fibrillatory rate and risk of left atrial thrombus in atrial fibrillation.
  • 2007
  • Ingår i: Europace. - : Oxford University Press (OUP). - 1532-2092. ; 9:8, s. 6-621
  • Tidskriftsartikel (refereegranskat)abstract
    • ims In atrial fibrillation (AF), a relation between electrocardiogram (ECG) fibrillatory wave amplitude and thrombus formation has been sought for long with conflicting results. In contrast, the possible relation between atrial fibrillatory rate obtained from the surface ECG and left atrial thrombus formation in patients with AF is unknown and was consequently evaluated in this study. Methods and results One-hundred and twenty-five patients (mean age 64 ± 12 years, 72% male) with persistent non-valvular AF (mean duration 28 ± 80 days) undergoing transesophageal echocardiography were studied. In all patients, standard 12-lead ECG recordings were acquired before the examination. Atrial fibrillatory rate was determined using spatiotemporal QRST cancellation and time–frequency analysis of lead V1. Atrial fibrillatory rate measured 401 ± 63 fibrillations per minute (fpm, range 235–566 fpm) and was related with age (R = −0.326, P < 0.001), ventricular rate (R = −0.202, P = 0.024), gender (407 ± 62 in males vs. 387 ± 64 fpm in females, P = 0.038) but not AF duration (R = 0.088, P = 0.374), presence of lone AF (408 ± 66 vs. 394 ± 58 fpm, P = 0.228), or beta-blocker or calcium channel blocker treatment (398 ± 63 vs. 405 ± 62 fpm, P = 0.556). Age was the only independent predictor of fibrillatory rate (B = −1.714, P < 0.001). In patients with left atrial thrombus (n = 10), spontaneous echo contrast (SEC) was more frequently present (70 vs. 29 %, p = 0.007) and left atrial appendage (LAA) outflow velocity was lower (26 ± 20 vs. 37 ± 15 cm/s, P = 0.012) than in patients without thrombus (n = 115). In contrast, mean fibrillatory rate, which showed a weak inverse correlation with LAA velocity (R = −0.118, P = 0.048) was not different between both groups (380 ± 56 vs. 403 ± 63 fpm, P = 0.226). Similarly, presence of thrombus and SEC combined was not related with fibrillatory rate. Conclusion Atrial fibrillatory rate obtained from surface ECG lead V1 is not a risk marker for left atrial thrombus formation in AF.
  •  
9.
  • Borgquist, Rasmus, et al. (författare)
  • Cardiac Resynchronization Therapy Guided by Echocardiography, MRI, and CT Imaging : A Randomized Controlled Study
  • 2020
  • Ingår i: JACC: Clinical Electrophysiology. - : Elsevier BV. - 2405-500X. ; 6:10, s. 1300-1309
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: This study evaluated if selecting the left ventricular (LV) target segment by echocardiography-derived late mechanical activation, with access to multimodality imaging for scar and venous anatomy, could help to increase responder rates to cardiac resynchronization therapy (CRT). Background: LV lead placement is important for clinical outcome, but the optimal strategy for LV lead placement in CRT is still debated. Methods: This study conducted a prospective, blinded randomized controlled trial on 102 patients with indication for CRT (27% women, 46% with ischemic cardiomyopathy, 63% in New York Heart Association functional class III, 74% with left bundle branch block, and with mean ejection fraction of 23%). Optimal LV lead location was defined as the latest mechanically activated available segment (free of transmural scar), determined by radial strain echocardiography, cardiac computed tomography, and cardiac magnetic resonance (n = 70). The primary endpoint was reduction of LV end-systolic volume by ≥15% at 6 months post-implantation. Results: Patients were followed for 47 ± 21 months. Based on imaging, optimal or adjacent lead placement was feasible in 96% of all cases and was obtained in 83% of the intervention group versus 80% of the control group. Fifty-six percent of the patients were LV end-systolic volume responders compared with the control group (55%) (p = 0.96), and 71% improved ≥1 New York Heart Association functional class (74% vs. 67%; p = 0.43). Death or heart failure hospitalization within 2 years occurred in 6% (2% of the intervention group vs. 10% of the control group; p = 0.07). Conclusions: Radial strain-guided LV lead placement, in combination with multimodality imaging, did not result in increased clinical or echocardiographic response, nor in a significant reduction of death or heart failure hospitalization. (Combining Myocardial Strain and Cardiac CT to Optimize Left Ventricular Lead Placement in CRT Treatment [CRT Clinic]; NCT01426321)
  •  
10.
  • Choudhary, Mariam B, et al. (författare)
  • Low atrial fibrillatory rate is associated with spontaneous conversion of recent-onset atrial fibrillation.
  • 2013
  • Ingår i: Europace. - : Oxford University Press (OUP). - 1532-2092. ; 15:10, s. 1445-1452
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: Atrial fibrillatory rate (AFR) is considered a non-invasive index of atrial remodelling. Low AFR has been associated with favourable outcome of interventions in patients with persistent atrial fibrillation (AF). However, AFR has never been studied in unselected patients with short duration of AF, prone to regain sinus rhythm (SR) spontaneously. The aim of the study was to assess if AFR can predict spontaneous conversion in patients with recent-onset AF.METHODS AND RESULTS: Files of consecutive patients with AF < 48 h seeking emergency room care during a 12-month period were screened (n = 225). Patients with thyroid illness, acute ischaemic heart disease (IHD) or acute congestive heart failure, significant valvular heart disease, congenital heart disease, history of cardiac surgery or catheter ablation, or on class I/III antiarrhythmics were excluded. Atrial fibrillatory rate was obtained by QRST cancellation and time frequency analysis of electrocardiogram at admission. The study population comprised 148 patients (age 64 ± 13 years, 52 men), of whom 48 converted to SR within 18 h. Those converting spontaneously comprised more women, had a higher prevalence of first-ever AF episode, IHD, and a lower AFR. The multivariate analysis revealed: AFR < 350 fibrillations per minute [odds ratio (OR) 3.7, 95% confidence interval (CI) 1.3-10.5, P = 0.016], IHD (OR 5.7, 95% CI 1.5-22.4, P = 0.012) and first-ever AF episode (OR 4.1, 95% CI 1.3-13.0, P = 0.015) as independent predictors of spontaneous conversion.CONCLUSION: A low AFR was predictive of spontaneous conversion in patients with recent-onset AF. Along with first-ever AF episode and IHD, AFR can be used in assessing likelihood of spontaneous conversion, if proven in prospective studies.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 62

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy