SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Roijer E) "

Sökning: WFRF:(Roijer E)

  • Resultat 1-10 av 11
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Holmqvist, Fredrik, et al. (författare)
  • Atrial fibrillation signal organization predicts sinus rhythm maintenance in patients undergoing cardioversion of atrial fibrillation.
  • 2006
  • Ingår i: Europace. - : Oxford University Press (OUP). - 1532-2092. ; 8:8, s. 559-565
  • Tidskriftsartikel (refereegranskat)abstract
    • Electrical remodelling is believed to influence the outcome following cardioversion of patients with persistent atrial fibrillation (AF). However, the results in clinical studies are conflicting. We assessed the hypothesis that non-invasively obtained atrial fibrillatory organization can be used as a predictor of sinus rhythm (SR) maintenance. METHODS AND RESULTS: Fifty-four patients (37 men, age 67+/-11) with persistent AF (median duration 3 months, 1 day to 18 months), without anti-arrhythmic drug treatment, referred for cardioversion were studied. Assessment of the atrial harmonic decay was made by time-frequency analysis of the ECG. At 1-month follow-up, 30 patients had relapsed into AF. The mean harmonic decay at inclusion of those relapsing into AF was 1.5+/-0.3 compared with 1.1+/-0.3 among those maintaining SR (P=0.0004). Using a cut-off value of harmonic decay
  •  
3.
  • Holmqvist, Fredrik, et al. (författare)
  • Indices of electrical and contractile remodeling during atrial fibrillation in man
  • 2006
  • Ingår i: PACE. - : Wiley. - 1540-8159. ; 29:5, s. 512-519
  • Tidskriftsartikel (refereegranskat)abstract
    • Atrial electrical and contractile remodeling have been demonstrated to coincide during atrial fibrillation (AF) in experimental studies. We explored whether electrical and contractile remodeling correlate in man and explored its clinical implications. METHODS: Forty-nine patients with persistent AF were studied. Electrical remodeling was assessed noninvasively using spectral analysis to estimate the average fibrillatory rate (AFR). Atrial contractility was assessed by transesophageal echocardiography (TEE) measurement of left atrial appendage outflow velocity (LAAOV). RESULTS: The AFR was 403+/-43 fibrillations per minute (fpm) and the LAAOV was 0.27+/-0.14 m/s. A significant correlation was found between AFR and LAAOV (r=-0.47, P=0.001). In patients with a LAAOV>or=0.25 m/s, the AFR was 387+/-48 fpm compared to 419+/-31 fpm among patients with LAAOV<0.25 m/s (P<0.01). CONCLUSIONS: This study demonstrates that indices of electrical and contractile remodeling are strongly correlated in persistent AF in man. The interindividual overlap, however, is too large to allow predictions of LAAOV based on fibrillatory frequency alone.
  •  
4.
  • Holmqvist, Fredrik, et al. (författare)
  • Rapid fluctuations in atrial fibrillatory electrophysiology detected during controlled respiration.
  • 2005
  • Ingår i: American Journal of Physiology: Heart and Circulatory Physiology. - : American Physiological Society. - 1522-1539 .- 0363-6135. ; 289:2, s. 754-760
  • Tidskriftsartikel (refereegranskat)abstract
    • Heart rate during sinus rhythm is modulated through the autonomic nervous system, which generates short-term oscillations. The high-frequency components in these oscillations are associated with respiration, causing sinus arrhythmia, mediated by the parasympathetic nervous system. In this study, we evaluated whether slow, controlled respiration causes cyclic fluctuations in the frequency of the fibrillating atria. Eight patients (four women; median age 63 yr, range 53–68 yr) with chronic atrial fibrillation (AF) and third-degree atrioventricular block treated by permanent pacemaker were studied. ECG was recorded during baseline rest, during 0.125-Hz frequency controlled respiration, and finally during controlled respiration after full vagal blockade. We calculated fibrillatory frequency using frequency analysis of the fibrillatory ECG for overlapping 2.5-s segments; spectral analysis of the resulting frequency trend was performed to determine the spectrum of variations of fibrillatory frequency. Normalized spectral power at respiration frequency increased significantly during controlled respiration from 1.4 (0.76–2.0) (median and range) at baseline to 2.7 (1.2–5.8) ( P = 0.01). After vagal blockade, the power at respiration frequency decreased to 1.2 (0.23–2.8) ( P = 0.01). Controlled respiration causes cyclic fluctuations in the AF frequency in patients with long-duration AF. This phenomenon seems to be related to parasympathetic modulations of the AF refractory period.
  •  
5.
  •  
6.
  •  
7.
  •  
8.
  •  
9.
  •  
10.
  • Werther Evaldsson, A., et al. (författare)
  • Echocardiographic right ventricular strain from multiple apical views is superior for assessment of right ventricular systolic function
  • 2019
  • Ingår i: Clinical Physiology and Functional Imaging. - : Wiley. - 1475-0961. ; 39:2, s. 168-176
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Right ventricular (RV) systolic function is an important determinant of outcome in patients with pulmonary hypertension (PH). Conventional echocardiographic measures of RV are mainly based on longitudinal contractility. Recently, measurement of RV global longitudinal strain derived from multiple windows (RVGLS) has emerged as an option but has not been well evaluated. The aim of the present study was to evaluate which echocardiographic RV function parameter correlates best with RV ejection fraction derived from cardiac magnetic resonance imaging (RVEFCMR). Methods and results: Fifty-five patients evaluated for PH underwent RV assessment with echocardiography and CMR. Conventional echocardiographic parameters of RV function including tricuspid annular plane systolic excursion (TAPSE), tricuspid annular systolic velocity (S′), RV fractional area change (RVFAC) and RV index of myocardial performance (RIMP). RVGLS was measured from three separate apical views using a 17-segment model and strain from the lateral free wall was calculated separately (RVfree). The study included 55 patients, whereas assessment of RVGLS could be obtained in 29 patients. The Pearson correlation coefficient with RVEFCMR was strong for RVGLS (r = 0·814, P<0·001) and RVfree (r = 0·778, P<0·001), modest for RVFAC (r = 0·681, P<0·001), TAPSE (r = 0·592, P<0·001) and RIMP (r=−0·521, P<0·01), and weak for S′ (r = 0·385, P<0·01). Conclusion: The echocardiographic RV measures, RVGLS and RVfree correlated well with RVEFCMR, whereas correlation with TAPSE, RIMP and S′ was unsatisfactory. Our findings suggest that RVGLS and RVfree are the preferred echocardiographic methods for clinical practice. RVfree is easiest to perform but RVGLS could provide incremental value in selected patients.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 11

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy