SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Rolander B.) "

Sökning: WFRF:(Rolander B.)

  • Resultat 1-10 av 22
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Shergur, J., et al. (författare)
  • beta-decay studies of Sn135-137 using selective resonance laser ionization techniques
  • 2002
  • Ingår i: Physical Review C - Nuclear Physics. - 2469-9985 .- 2469-9993. ; 65:3
  • Tidskriftsartikel (refereegranskat)abstract
    • The decays of the very neutron rich Sn isotopes Sn135-137 were studied at CERN/ISOLDE using isotopic and isobaric selectivity achieved by the use of a resonance ionization laser ion source and mass spectroscopy, respectively. Neutron decay rates, gamma-ray singles, and gamma-gamma coincidence data were collected as a function of time. The half-life (T-1/2) and delayed neutron emission probability (P-n) values of 135 Sn were measured to be 530(20) ms and 21(3)%, respectively. For Sn-136, a T-1/2 of 250(30) ms was determined along with a P-n value of 30(5)%. For Sn-137, a T-1/2 of 190(60) ms and a P-n value of 58(15)% were deduced. Identification of low-energy transitions in Sb-135 was made possible by comparison of laser-on and laser-off gamma-ray spectra. Those data combined with gamma-gamma coincidence spectra were used to construct a level scheme for Sb-135 that includes an unexpectedly low first excited state at 282 keV. A ground state beta branch of 33.2% was measured by following the growth and decay of the Sb-135 daughter. Shell-model calculations are consistent with the observed Sb-135 level structure and can account for a lowered first excited state.
  •  
2.
  •  
3.
  •  
4.
  • Bergmann, U. C., et al. (författare)
  • Analysis of decay data from neutron-rich nuclei
  • 2001
  • Ingår i: European Physical Journal A. - 1434-601X .- 1434-6001. ; 11:3, s. 279-284
  • Tidskriftsartikel (refereegranskat)abstract
    • The beta -decays of the neutron-rich nuclei Be-12 and Ne-29 have been studied. The statistical correlations between the almost identical half-lives of Be-12 and its daughter B-12 are analysed for a large sample of Be-12 decay data. Stringent mutual bounds are obtained on the parameter set, leading to a precise determination of the Be-12 half-life of 21.50 +/- 0.04 ms. From a simultaneous detection of beta -particles and neutrons from the decay of Ne-29 the neutron emission probability, P-n, is determined to 17 +/- 5%. No indication of two-neutron emission is seen from this nucleus. An upper limit of 2.2% (90% confidence level) is established for P-2n.
  •  
5.
  • Falck, Johanna, et al. (författare)
  • Women with lipoedema : a national survey on their health, health-related quality of life, and sense of coherence
  • 2022
  • Ingår i: BMC Women's Health. - : BioMed Central (BMC). - 1472-6874. ; 22:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Lipoedema is a chronic disease in adipose tissue that almost exclusively affects women during periods of hormonal alterations. Its main symptoms include an abnormal accumulation of subcutaneous fat in the buttock, hips, and legs, which is associated with pain, swelling, and easy bruising. Herein, a grading in three stages is used to determine disease progression. Problematically, lipoedema manifestations are often confused with lifestyle-induced obesity, which is why the various health problems among affected women often remain unrecognized. Overall, research on lipoedema is scarce. As such, this study examined the health, health-related quality of life (HRQOL), and sense of coherence (SOC) among women with lipoedema. Methods: We conducted a national cross-sectional study using an online survey assessing sociodemographic data, lipoedema characteristics, symptom severity, comorbidities, HRQOL (RAND-36), and SOC (SOC-13). In total, 245 women with lipoedema, recruited from all Lipoedema Association groups in Sweden, participated. Data were compiled with descriptive statistics, and mean differences between groups were analysed by using parametric and non-parametric tests. Results: Moderate and severe leg heaviness, pain, numbness, cold skin, feeling cold, easy bruising, and sleep problems were found to occur in all lipoedema stages. Moreover, almost all participants reported having comorbidities. Worse physical health and most substantial limitations in daily life were reported among women with the most progressive lipoedema (i.e., stage 3). Social and emotional functioning and SOC were found to be, on the other hand, primarily related to respondents’ sociodemographic data and their ages at lipoedema onset. Even though approximately 70% of the women had experienced lipoedema onset before age 30, only three (1.6%) had been diagnosed by a healthcare professional before that age. Conclusion: Having lipoedema is associated with several health problems and a lower HRQOL. In addition, the extent of delay in diagnosis within this sample indicates that many women with lipoedema are often underdiagnosed and are left without support from healthcare. These findings call for the need for greater attention on lipoedema. Moreover, further studies on how women with lipoedema manage their health and symptoms, as well as on their experiences of healthcare services and lipoedema treatments, are needed.
  •  
6.
  • Jeppesen, H. B., et al. (författare)
  • News on beta delayed particle emission from Be-14
  • 2002
  • Ingår i: Progress of Theoretical Physics Supplement. - 0375-9687. ; :146, s. 520-524
  • Konferensbidrag (refereegranskat)abstract
    • Beta delayed charged particles from Be-14 have been measured and give an upper limit on beta delayed alpha particles of B(betaalpha)
  •  
7.
  •  
8.
  • Jeppesen, H., et al. (författare)
  • News on beta delayed particle emission from 14Be
  • 2002
  • Ingår i: Progress of Theoretical Physics. - 0033-068X. ; :146 SUPPL., s. 520-524
  • Tidskriftsartikel (refereegranskat)abstract
    • Beta delayed charged particles from 14Be have been measured and give an upper limit on beta delayed alpha particles of B(βα)<6.7×10-5 and a tentative branching ratio on beta delayed tritons of 7.5×10-5
  •  
9.
  • Johansson, Lisbeth, et al. (författare)
  • Agreement between questions about physical activity and sitting time, and device-based measures, used in Swedish targeted health dialogues in the context of primary health care
  • 2023
  • Ingår i: BMC Sports Science, Medicine and Rehabilitation. - : BioMed Central (BMC). - 2052-1847. ; 15:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: It is important that easy-to-use measures like subjective questions about physical activity (PA) and sedentary behaviour are valid and reliable providing accurate measures, when they are used in health promotion work aiming to support people to improve their lifestyle habits such as PA. The aim of this study was to evaluate the concurrent validity of a structured interview form estimating self-reported PA and a question about sitting time used in Swedish targeted health dialogues in the context of primary health care. Method: The study was conducted in the southern part of Sweden. To evaluate concurrent validity of the interview form, time spent in moderate-to-vigorous physical activities (MVPA) and energy expenditure related to MVPA estimated by an interview form was compared with the same measures assessed by an ActiGraph GT3X-BT accelerometer. To evaluate a question about sitting time, the Swedish School of Sport and Health Sciences’ single-item question about sitting time (SED-GIH) was compared with measures from an activPAL inclinometer. Statistical analyses included deriving Bland‒Altman plots and calculating Spearman’s rank correlation coefficients. Result: Bland‒Altman plots indicated lower absolute variation in the difference between self-reported and device-based PA measures for lower PA levels, both for energy expenditure and time spent in MVPA. No systematic over- or underestimation was observed. The Spearman’s correlation coefficient between self-reported and device-based PA measures was 0.27 (p = 0.014) for time spent in MVPA and 0.26 (p = 0.022) for energy expenditure. The correlation coefficient between the single item question and device-based sitting time measures was 0.31 (p = 0.002). Sitting time was underestimated by 74% of the participants. Conclusion: The PA interview form and the SED-GIH question on sitting time may be of value in targeted health dialogues in primary health care with the intention to support sedentary and insufficiently physically active persons in increasing their physical activity and limiting their sitting time. The questionnaires are easy to use and are more cost effective than device-based measures, especially regarding population-based interventions conducted in primary health care for thousands of participants such as targeted health dialogues. Clinical trial registration: Not applicable.
  •  
10.
  • Jonker, D., et al. (författare)
  • Health surveillance under adverse ergonomics conditions – validity of a screening method adapted for the occupational health service
  • 2015
  • Ingår i: Ergonomics. - : Informa UK Limited. - 0014-0139 .- 1366-5847. ; 58:9, s. 1519-1528
  • Tidskriftsartikel (refereegranskat)abstract
    • A new health surveillance protocol for work-related upper-extremity musculoskeletal disorders has been validated by comparing the results with a reference protocol. The studied protocol, Health Surveillance in Adverse Ergonomics Conditions (HECO), is a new version of the reference protocol modified for application in the Occupational Health Service (OHS). The HECO protocol contains both a screening part and a diagnosing part. Sixty-three employees were examined. The screening in HECO did not miss any diagnosis found when using the reference protocol, but in comparison to the reference protocol considerable time savings could be achieved. Fair to good agreement between the protocols was obtained for one or more diagnoses in neck/shoulders (86%, k=0.62) and elbow/hands (84%, k=0.49). Therefore, the results obtained using the HECO protocol can be compared with a reference material collected with the reference protocol, and thus provide information of the magnitude of disorders in an examined work group. Practitioner Summary: The HECO protocol is a relatively simple physical examination protocol for identification of musculoskeletal disorders in the neck and upper extremities. The protocol is a reliable and cost-effective tool for the OHS to use for occupational health surveillance in order to detect workplaces at high risk for developing musculoskeletal disorders. © 2015 The Author(s). Published by Taylor & Francis.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 22

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy