SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Rombi Barbara) "

Sökning: WFRF:(Rombi Barbara)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ajithkumar, Thankamma, et al. (författare)
  • SIOPE - Brain tumor group consensus guideline on craniospinal target volume delineation for high-precision radiotherapy
  • 2018
  • Ingår i: Radiotherapy and Oncology. - : ELSEVIER IRELAND LTD. - 0167-8140 .- 1879-0887. ; 128:2, s. 192-197
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: To develop a consensus guideline for craniospinal target volume (TV) delineation in children and young adults participating in SIOPE studies in the era of high-precision radiotherapy. Methods and materials: During four consensus meetings (Cambridge, Essen, Liverpool, and Marseille), conventional field-based TV has been translated into image-guided high-precision craniospinal TV by a group of expert paediatric radiation oncologists and enhanced by MRI images of liquor distribution. Results: The CTVcranial should include the whole brain, cribriform plate, most inferior part of the temporal lobes, and the pituitary fossa. If the full length of both optic nerves is not included, the dose received by different volumes of optic nerve should be recorded to correlate with future patterns of relapse (no consensus). The CTVcranial should be modified to include the dural cuffs of cranial nerves as they pass through the skull base foramina. Attempts to spare the cochlea by excluding CSF within the internal auditory canal should be avoided. The CTVspinal should include the entire subarachnoid space, including nerve roots laterally. The lower limit of the spinal CTV is at the lower limit of the thecal sac, best visible on MRI scan. There is no need to include sacral root canals in the spinal CTV. Conclusion: This consensus guideline has the potential to improve consistency of craniospinal TV delineation in an era of high-precision radiotherapy. This proposal will be incorporated in the RTQA guidelines of future SIOPE-BTG trials using CSI.
  •  
2.
  • Toussaint, Laura, et al. (författare)
  • Clinical practice in European centres treating paediatric posterior fossa tumours with pencil beam scanning proton therapy
  • 2024
  • Ingår i: RADIOTHERAPY AND ONCOLOGY. - 0167-8140 .- 1879-0887. ; 198
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose: As no guidelines for pencil beam scanning (PBS) proton therapy (PT) of paediatric posterior fossa (PF) tumours exist to date, this study investigated planning techniques across European PT centres, with special considerations for brainstem and spinal cord sparing. Materials and methods: A survey and a treatment planning comparison were initiated across nineteen European PBS-PT centres treating paediatric patients. The survey assessed all aspects of the treatment chain, including but not limited to delineations, dose constraints and treatment planning. Each centre planned two PF tumour cases for focal irradiation, according to their own clinical practice but based on common delineations. The prescription dose was 54 Gy(RBE) for Case 1 and 59.4 Gy (RBE) for Case 2. For both cases, planning strategies and relevant dose metrics were compared. Results: Seventeen (89 %) centres answered the survey, and sixteen (80 %) participated in the treatment planning comparison. In the survey, thirteen (68 %) centres reported using the European Particle Therapy Network definition for brainstem delineation. In the treatment planning study, while most centres used three beam directions, their configurations varied widely across centres. Large variations were also seen in brainstem doses, with a brainstem near maximum dose (D2%) ranging from 52.7 Gy(RBE) to 55.7 Gy(RBE) (Case 1), and from 56.8 Gy(RBE) to 60.9 Gy(RBE) (Case 2). Conclusion: This study assessed the European PBS-PT planning of paediatric PF tumours. Agreement was achieved in e.g. delineation-practice, while wider variations were observed in planning approach and consequently dose to organs at risk. Collaboration between centres is still ongoing, striving towards common guidelines.
  •  
3.
  • Trnková, Petra, et al. (författare)
  • Patterns of practice of image guided particle therapy for cranio-spinal irradiation : A site specific multi-institutional survey of European Particle Therapy Network
  • 2024
  • Ingår i: Physica medica (Testo stampato). - : Elsevier. - 1120-1797 .- 1724-191X. ; 123
  • Tidskriftsartikel (refereegranskat)abstract
    • PurposeTo investigate the current practice patterns in image-guided particle therapy (IGPT) for cranio-spinal irradiation (CSI).MethodsA multi-institutional survey was distributed to European particle therapy centres to analyse all aspects of IGPT. Based on the survey results, a Delphi consensus analysis was developed to define minimum requirements and optimal workflow for clinical practice. The centres participating in the institutional survey were invited to join the Delphi process.ResultsEleven centres participated in the survey. Imaging for treatment planning was rather similar among the centres with Computed Tomography (CT) being the main modality. For positioning verification, 2D IGPT was more commonly used than 3D IGPT. Two centres performed routinely imaging for plan adaptation, by the rest ad hoc. Eight centres participated in the Delphi consensus analysis. The full consensus was reached on the use of CT imaging without contrast for treatment planning and the role of magnetic resonance imaging (MRI) in target and organs-at-risk delineation. There was an agreement on the necessity to perform patient position verification and correction before each isocentre. The most important outcome was the clear need for standardization and harmonization of the workflow.ConclusionThere were differences in CSI IGPT clinical practice among the European particle therapy centres. Moreover, the optimal workflow as identified by experts was not yet reached. There is a strong need for consensus guidelines. The state-of-the-art imaging technology and protocols need to be implemented into clinical practice to improve the quality of IGPT for CSI.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy