SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Rondonotti Emanuele) "

Sökning: WFRF:(Rondonotti Emanuele)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Baltes, Peter, et al. (författare)
  • Small-bowel capsule endoscopy in patients with Meckel's diverticulum : clinical features, diagnostic workup, and findings. A European multicenter I-CARE study
  • 2023
  • Ingår i: Gastrointestinal Endoscopy. - : Elsevier BV. - 0016-5107. ; 97:5, s. 3-926
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and Aims: Meckel's diverticulum (MD) may remain silent or be associated with adverse events such as GI bleeding. The main aim of this study was to evaluate indicative small-bowel capsule endoscopy (SBCE) findings, and the secondary aim was to describe clinical presentation in patients with MD. Methods: This retrospective European multicenter study included patients with MD undergoing SBCE from 2001 until July 2021. Results: Sixty-nine patients with a confirmed MD were included. Median age was 32 years with a male-to-female ratio of approximately 3:1. GI bleeding or iron-deficiency anemia was present in nearly all patients. Mean hemoglobin was 7.63 ± 1.8 g/dL with a transfusion requirement of 52.2%. Typical capsule endoscopy (CE) findings were double lumen (n = 49 [71%]), visible entrance into the MD (n = 49 [71%]), mucosal webs (n = 30 [43.5%]), and bulges (n = 19 [27.5%]). Two or more of these findings were seen in 48 patients (69.6%). Ulcers were detected in 52.2% of patients (n = 36). In 63.8% of patients (n = 44), a combination of double lumen and visible entrance into the MD was evident, additionally revealing ulcers in 39.1% (n = 27). Mean percent SB (small bowel) transit time for the first indicative image of MD was 57% of the total SB transit time. Conclusions: Diagnosis of MD is rare and sometimes challenging, and a preoperative criterion standard does not exist. In SBCE, the most frequent findings were double-lumen sign and visible diverticular entrance, sometimes together with ulcers.
  •  
2.
  • Elli, Luca, et al. (författare)
  • Nomenclature and Definition of Atrophic Lesions in Small Bowel Capsule Endoscopy : A Delphi Consensus Statement of the International CApsule endoscopy REsearch (I-CARE) Group
  • 2022
  • Ingår i: Diagnostics. - : MDPI AG. - 2075-4418. ; 12:7
  • Tidskriftsartikel (refereegranskat)abstract
    • (1) Background: Villous atrophy is an indication for small bowel capsule endoscopy (SBCE). However, SBCE findings are not described uniformly and atrophic features are sometimes not recognized; (2) Methods: The Delphi technique was employed to reach agreement among a panel of SBCE experts. The nomenclature and definitions of SBCE lesions suggesting the presence of atrophy were decided in a core group of 10 experts. Four images of each lesion were chosen from a large SBCE database and agreement on the correspondence between the picture and the definition was evaluated using the Delphi method in a broadened group of 36 experts. All images corresponded to histologically proven mucosal atrophy; (3) Results: Four types of atrophic lesions were identified: mosaicism, scalloping, folds reduction, and granular mucosa. The core group succeeded in reaching agreement on the nomenclature and the descriptions of these items. Consensus in matching the agreed definitions for the proposed set of images was met for mosaicism (88.9% in the first round), scalloping (97.2% in the first round), and folds reduction (94.4% in the first round), but granular mucosa failed to achieve consensus (75.0% in the third round); (4) Conclusions: Consensus among SBCE experts on atrophic lesions was met for the first time. Mosaicism, scalloping, and folds reduction are the most reliable signs, while the description of granular mucosa remains uncertain.
  •  
3.
  • Koulaouzidis, Anastasios, et al. (författare)
  • KID Project : an internet-based digital video atlas of capsule endoscopy for research purposes
  • 2017
  • Ingår i: Endoscopy International Open. - : Georg Thieme Verlag KG. - 2364-3722 .- 2196-9736. ; 5:6, s. 477-483
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND AND AIMS: Capsule endoscopy (CE) has revolutionized small-bowel (SB) investigation. Computational methods can enhance diagnostic yield (DY); however, incorporating machine learning algorithms (MLAs) into CE reading is difficult as large amounts of image annotations are required for training. Current databases lack graphic annotations of pathologies and cannot be used. A novel database, KID, aims to provide a reference for research and development of medical decision support systems (MDSS) for CE.METHODS: Open-source software was used for the KID database. Clinicians contribute anonymized, annotated CE images and videos. Graphic annotations are supported by an open-access annotation tool (Ratsnake). We detail an experiment based on the KID database, examining differences in SB lesion measurement between human readers and a MLA. The Jaccard Index (JI) was used to evaluate similarity between annotations by the MLA and human readers.RESULTS: The MLA performed best in measuring lymphangiectasias with a JI of 81 ± 6 %. The other lesion types were: angioectasias (JI 64 ± 11 %), aphthae (JI 64 ± 8 %), chylous cysts (JI 70 ± 14 %), polypoid lesions (JI 75 ± 21 %), and ulcers (JI 56 ± 9 %).CONCLUSION: MLA can perform as well as human readers in the measurement of SB angioectasias in white light (WL). Automated lesion measurement is therefore feasible. KID is currently the only open-source CE database developed specifically to aid development of MDSS. Our experiment demonstrates this potential.
  •  
4.
  • Lazaridis, Lazaros Dimitrios, et al. (författare)
  • Implementation of European Society of Gastrointestinal Endoscopy (ESGE) recommendations for small-bowel capsule endoscopy into clinical practice : Results of an official ESGE survey
  • 2021
  • Ingår i: Endoscopy. - : Georg Thieme Verlag KG. - 0013-726X .- 1438-8812. ; 53:9, s. 970-980
  • Tidskriftsartikel (refereegranskat)abstract
    • Background We aimed to document international practices in small-bowel capsule endoscopy (SBCE), measuring adherence to European Society of Gastrointestinal Endoscopy (ESGE) technical and clinical recommendations. Methods Participants reached through the ESGE contact list completed a 52-item web-based survey. Results 217 responded from 47 countries (176 and 41, respectively, from countries with or without a national society affiliated to ESGE). Of respondents, 45 % had undergone formal SBCE training. Among SBCE procedures, 91 % were performed with an ESGE recommended indication, obscure gastrointestinal bleeding (OGIB), iron-deficiency anemia (IDA), and suspected/established Crohn’s disease being the commonest and with higher rates of positive findings (49.4 %, 38.2 % and 53.5 %, respectively). A watchful waiting strategy after a negative SBCE for OGIB or IDA was preferred by 46.7 % and 70.3 %, respectively. SBCE was a second-line exam for evaluation of extent of new Crohn’s disease for 62.2 % of respondents. Endoscopists adhered to varying extents to ESGE technical recommendations regarding bowel preparation ( > 60 %), use in those with pacemaker holders (62.5 %), patency capsule use (51.2 %), and use of a validated scale for bowel preparation assessment (13.3 %). Of the respondents, 67 % read and interpreted the exams themselves and 84 % classified exams findings as relevant or irrelevant. Two thirds anticipated future increase in SBCE demand. Inability to obtain tissue (78.3 %) and high cost (68.1 %) were regarded as the main limitations, and implementation of artificial intelligence as the top development priority (56.2 %). Conclusions To some extent, endoscopists follow ESGE guidelines on using SBCE in clinical practice. However, variations in practice have been identified, whose implications require further evaluation.
  •  
5.
  • Leenhardt, Romain, et al. (författare)
  • PEACE : Perception and expectations toward artificial intelligence in capsule endoscopy
  • 2021
  • Ingår i: Journal of Clinical Medicine. - : MDPI AG. - 2077-0383. ; 10:23
  • Tidskriftsartikel (refereegranskat)abstract
    • Artificial intelligence (AI) has shown promising results in digestive endoscopy, especially in capsule endoscopy (CE). However, some physicians still have some difficulties and fear the advent of this technology. We aimed to evaluate the perceptions and current sentiments toward the use of AI in CE. An online survey questionnaire was sent to an audience of gastroenterologists. In addition, several European national leaders of the International CApsule endoscopy REsearch (I CARE) Group were asked to disseminate an online survey among their national communities of CE readers (CER). The survey included 32 questions regarding general information, perceptions of AI, and its use in daily life, medicine, endoscopy, and CE. Among 380 European gastroenterologists who answered this survey, 333 (88%) were CERs. The mean average time length of experience in CE reading was 9.9 years (0.5–22). A majority of CERs agreed that AI would positively impact CE, shorten CE reading time, and help standardize reporting in CE and characterize lesions seen in CE. Nevertheless, in the foreseeable future, a majority of CERs disagreed with the complete replacement all CE reading by AI. Most CERs believed in the high potential of AI for becoming a valuable tool for automated diagnosis and for shortening the reading time. Currently, the perception is that AI will not replace CE reading.
  •  
6.
  • Yung, Diana E., et al. (författare)
  • Capsule endoscopy in young patients with iron deficiency anaemia and negative bidirectional gastrointestinal endoscopy
  • 2017
  • Ingår i: United European Gastroenterology Journal. - : Wiley. - 2050-6406 .- 2050-6414. ; 5:7, s. 974-981
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Recent data imply young patients (age ≤50 years) undergoing small-bowel (SB) capsule endoscopy (CE) for iron deficiency anaemia (IDA) show higher diagnostic yield (DY) for sinister pathology. We aimed to investigate DY of CE in a large cohort of young IDA patients, and evaluate factors predicting significant SB pathology. Materials and methods: This was a retrospective, multicentre study (2010–2015) in consecutive, young patients (≤50 years) from 18 centres/12 countries, with negative bidirectional gastrointestinal (GI) endoscopy undergoing SBCE for IDA. Exclusion criteria: previous/ongoing obscure-overt GI bleeding; age <19 or >50 years; comorbidities associated with IDA. Data retrieved: SBCE indications; prior investigations; medications; SBCE findings; final diagnosis. Clinical and laboratory data were analysed by multivariate logistic regression. Results: Data on 389 young IDA patients were retrieved. In total, 169 (43.4%) were excluded due to incomplete clinical data; data from 220 (122F/98M; mean age 40.5 ± 8.6 years) patients were analysed. Some 71 patients had at least one clinically significant SBCE finding (DY: 32.3%). They were divided into two groups: neoplastic pathology (10/220; 4.5%), and non-neoplastic but clinically significant pathology (61/220; 27.7%). The most common significant but non-neoplastic pathologies were angioectasias (22/61) and Crohn’s disease (15/61). On multivariate analysis, weight loss and lower mean corpuscular volume(MCV) were associated with significant SB pathology (OR: 3.87; 95%CI: 1.3–11.3; p = 0.01; and OR: 0.96; 95%CI: 0.92–0.99; p = 0.03; respectively). Our model also demonstrates association between use of antiplatelets and significant SB pathology, although due to the small number of patients, definitive conclusions cannot be drawn. Conclusion: In IDA patients ≤50 years with negative bidirectional GI endoscopy, overall DY of SBCE for clinically significant findings was 32.3%. Some 5% of our cohort was diagnosed with SB neoplasia; lower MCV or weight loss were associated with higher DY for SB pathology.
  •  
7.
  • Yung, Diana E., et al. (författare)
  • Clinical outcomes of negative small-bowel capsule endoscopy for small-bowel bleeding : A systematic review and meta-analysis
  • 2017
  • Ingår i: Gastrointestinal Endoscopy. - : Elsevier BV. - 0016-5107. ; 85:2, s. 2-317
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and Aims: Small-bowel bleeding is the primary indication for capsule endoscopy (CE). Many experts advocate a "watch-and-wait" policy in negative CE. This meta-analysis examines the odds of rebleeding after negative index CE and the impact on long-term follow-up. Methods: A comprehensive literature search identified articles examining the rebleeding rate after negative CE. Demographic and clinical information with emphasis on outcomes was retrieved, pooled, and analyzed. Heterogeneity among studies was assessed using the I2 statistic. A random effects model was used as the pooling method because of high heterogeneity. Risk of bias was assessed using the quality assessment of diagnostic accuracy studies (QUADAS-2) tool. The primary outcome evaluated was the pooled odds ratios (ORs) for rebleeding after a negative CE for obscure GI bleeding (OGIB). Results: Twenty-six studies with 3657 patients were included. The pooled rate of rebleeding after negative CE was .19 (95% CI, .14-.25; . P < .0001). The pooled OR of rebleeding was .59 (95% CI, .37-.95; . P < .001). The effect was more pronounced in studies with a short follow-up (OR, .47; 95% CI, .24-.94; . P < .001). There was no statistically significant difference in rebleeding after CE for occult and overt OGIB. Prospective studies showed a lower OR of rebleeding of .24 (95% CI, .08-.73; . P = .01). Most studies were high quality. Conclusions: Our analysis shows that negative CE provides adequate evidence of a subsequently low risk of rebleeding. Such patients can therefore be safely managed with watchful waiting. However, patients who rebleed after 2 years may need to be investigated for a new source of blood loss.
  •  
8.
  • Yung, Diana E, et al. (författare)
  • Clinical validity of flexible spectral imaging color enhancement (FICE) in small-bowel capsule endoscopy : a systematic review and meta-analysis
  • 2017
  • Ingår i: Endoscopy. - : Georg Thieme Verlag KG. - 0013-726X .- 1438-8812. ; 49:3, s. 258-269
  • Forskningsöversikt (refereegranskat)abstract
    • Patients and methods A comprehensive literature search was conducted. We measured pooled rate of lesion visualization improvement and improvement in lesion detection comparing FICE settings 1 – 3 and WLE, for angioectasias and ulcers/erosions. Pooled results were derived using the random-effects model because of high heterogeneity as measured by I 2. Repeated-measures analysis of variance (ANOVA) was used to measure differences in lesion detection between WLE and the three FICE modes. Results 13 studies were analyzed. All studies used the PillCam SB 1 and/or SB 2 devices. Most used experienced readers. Improvement in delineation had been investigated in 4 studies; in the 3 studies entered into the meta-analysis, using FICE setting 1, 89 % of angioectasias and 45 % of ulcer/erosions were considered to show improved delineation. For FICE settings 2 and 3, small proportions of images showed improved delineation. Heterogeneity of studies was high with I 2 > 90 % in 4/6 analyses. Lesion detection had been investigated in 10 studies; meta-analysis included 5 studies. Lesion detection did not differ significantly between any of the FICE modes and WLE. Conclusions Overall, the use of the three FICE modes did not significantly improve delineation or detection rate in SBCE. In pigmented lesions, FICE setting 1 performed better in lesion delineation and detection.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy