SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Saboury B.) "

Sökning: WFRF:(Saboury B.)

  • Resultat 1-1 av 1
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Piri, R., et al. (författare)
  • "Global" cardiac atherosclerotic burden assessed by artificial intelligence-based versus manual segmentation in F-18-sodium fluoride PET/CT scans: Head-to-head comparison
  • 2022
  • Ingår i: Journal of Nuclear Cardiology. - : Springer Science and Business Media LLC. - 1071-3581 .- 1532-6551. ; 29:5, s. 2531-2539
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Artificial intelligence (AI) is known to provide effective means to accelerate and facilitate clinical and research processes. So in this study it was aimed to compare a AI-based method for cardiac segmentation in positron emission tomography/computed tomography (PET/CT) scans with manual segmentation to assess global cardiac atherosclerosis burden. Methods A trained convolutional neural network (CNN) was used for cardiac segmentation in F-18-sodium fluoride PET/CT scans of 29 healthy volunteers and 20 angina pectoris patients and compared with manual segmentation. Parameters for segmented volume (Vol) and mean, maximal, and total standardized uptake values (SUVmean, SUVmax, SUVtotal) were analyzed by Bland-Altman Limits of Agreement. Repeatability with AI-based assessment of the same scans is 100%. Repeatability (same conditions, same operator) and reproducibility (same conditions, two different operators) of manual segmentation was examined by re-segmentation in 25 randomly selected scans. Results Mean (+/- SD) values with manual vs. CNN-based segmentation were Vol 617.65 +/- 154.99 mL vs 625.26 +/- 153.55 mL (P = .21), SUVmean 0.69 +/- 0.15 vs 0.69 +/- 0.15 (P = .26), SUVmax 2.68 +/- 0.86 vs 2.77 +/- 1.05 (P = .34), and SUVtotal 425.51 +/- 138.93 vs 427.91 +/- 132.68 (P = .62). Limits of agreement were - 89.42 to 74.2, - 0.02 to 0.02, - 1.52 to 1.32, and - 68.02 to 63.21, respectively. Manual segmentation lasted typically 30 minutes vs about one minute with the CNN-based approach. The maximal deviation at manual re-segmentation was for the four parameters 0% to 0.5% with the same and 0% to 1% with different operators. Conclusion The CNN-based method was faster and provided values for Vol, SUVmean, SUVmax, and SUVtotal comparable to the manually obtained ones. This AI-based segmentation approach appears to offer a more reproducible and much faster substitute for slow and cumbersome manual segmentation of the heart.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-1 av 1

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy