SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Sack Ulrich) "

Sökning: WFRF:(Sack Ulrich)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Agmon-Levin, Nancy, et al. (författare)
  • International recommendations for the assessment of autoantibodies to cellular antigens referred to as anti-nuclear antibodies
  • 2014
  • Ingår i: Annals of the Rheumatic Diseases. - : BMJ. - 0003-4967 .- 1468-2060. ; 73:1, s. 17-23
  • Tidskriftsartikel (refereegranskat)abstract
    • Anti-nuclear antibodies (ANA) are fundamental for the diagnosis of autoimmune diseases, and have been determined by indirect immunofluorescence assay (IIFA) for decades. As the demand for ANA testing increased, alternative techniques were developed challenging the classic IIFA. These alternative platforms differ in their antigen profiles, sensitivity and specificity, raising uncertainties regarding standardisation and interpretation of incongruent results. Therefore, an international group of experts has created recommendations for ANA testing by different methods. Two groups of experts participated in this initiative. The European autoimmunity standardization initiative representing 15 European countries and the International Union of Immunologic Societies/World Health Organization/Arthritis Foundation/Centers for Disease Control and Prevention autoantibody standardising committee. A three-step process followed by a Delphi exercise with closed voting was applied. Twenty-five recommendations for determining ANA (1-13), anti-double stranded DNA antibodies (14-18), specific antibodies (19-23) and validation of methods (24-25) were created. Significant differences between experts were observed regarding recommendations 24-25 (p<0.03). Here, we formulated recommendations for the assessment and interpretation of ANA and associated antibodies. Notably, the roles of IIFA as a reference method, and the importance of defining nuclear and cytoplasmic staining, were emphasised, while the need to incorporate alternative automated methods was acknowledged. Various approaches to overcome discrepancies between methods were suggested of which an improved bench-to-bedside communication is of the utmost importance. These recommendations are based on current knowledge and can enable harmonisation of local algorithms for testing and evaluation of ANA and related autoantibodies. Last but not least, new more appropriate terminologies have been suggested.
  •  
3.
  • Bonroy, Carolien, et al. (författare)
  • Detection of antinuclear antibodies : recommendations from EFLM, EASI and ICAP
  • 2023
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter. - 1434-6621 .- 1437-4331. ; 61:7, s. 1167-1198
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: Antinuclear antibodies (ANA) are important for the diagnosis of various autoimmune diseases. ANA are usually detected by indirect immunofluorescence assay (IFA) using HEp-2 cells (HEp-2 IFA). There are many variables influencing HEp-2 IFA results, such as subjective visual reading, serum screening dilution, substrate manufacturing, microscope components and conjugate. Newer developments on ANA testing that offer novel features adopted by some clinical laboratories include automated computer-assisted diagnosis (CAD) systems and solid phase assays (SPA).Methods: A group of experts reviewed current literature and established recommendations on methodological aspects of ANA testing. This process was supported by a two round Delphi exercise. International expert groups that participated in this initiative included (i) the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group “Autoimmunity Testing”; (ii) the European Autoimmune Standardization Initiative (EASI); and (iii) the International Consensus on ANA Patterns (ICAP).Results: In total, 35 recommendations/statements related to (i) ANA testing and reporting by HEp-2 IFA; (ii) HEp-2 IFA methodological aspects including substrate/conjugate selection and the application of CAD systems; (iii) quality assurance; (iv) HEp-2 IFA validation/verification approaches and (v) SPA were formulated. Globally, 95% of all submitted scores in the final Delphi round were above 6 (moderately agree, agree or strongly agree) and 85% above 7 (agree and strongly agree), indicating strong international support for the proposed recommendations.Conclusions: These recommendations are an important step to achieve high quality ANA testing.
  •  
4.
  • Borte, Stephan, et al. (författare)
  • Neonatal screening for severe primary immunodeficiency diseases using high-throughput triplex real-time PCR.
  • 2012
  • Ingår i: Blood. - : American Society of Hematology. - 1528-0020 .- 0006-4971. ; 119:11, s. 2552-2555
  • Tidskriftsartikel (refereegranskat)abstract
    • Severe combined immunodeficiency (SCID) and X-linked agammaglobulinemia (XLA) are inborn errors of immune function that require prompt diagnosis and treatment to prevent life-threatening infections. The lack of functional T- or B-lymphocytes in these diseases serves as a diagnostic criterion and can be applied to neonatal screening. A robust triplex PCR method for quantitation of T cell receptor- (TREC) and kappa-deleting recombination excision circles (KREC), using a single Guthrie card punch, was developed and validated in a cohort of 2.560 anonymized newborn screening cards and in 50 original stored Guthrie cards from patients diagnosed with SCID, XLA, Ataxia-telangiectasia (AT), Nijmegen-breakage-syndrome (NBS), Common variable immunodeficiency (CVID), Immunoglobulin-A-deficiency (IgAD), or X-linked Hyper-IgM-syndrome (X-HIGM). Simultaneous measurement of TREC and KREC copy numbers in Guthrie card samples readily identified patients with SCID, XLA, AT and NBS and thus facilitates effective newborn screening for severe immunodeficiency syndromes characterized by the absence of T or B cells.
  •  
5.
  • Dragon-Durey, Marie-Agnès, et al. (författare)
  • Repository of intra-and inter-run variations of quantitative autoantibody assays: A European multicenter study
  • 2022
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - : De Gruyter Open. - 1434-6621 .- 1437-4331. ; 60:9, s. 1373-1383
  • Tidskriftsartikel (refereegranskat)abstract
    • No reference data are available on repositories to measure precision of autoantibody assays. The scope of this study was to document inter-and intra-run variations of quantitative autoantibody assays based on a real-world large international data set. Members of the European Autoimmunity Standardisation Initiative (EASI) group collected the data of intra-and inter-run variability obtained with assays quantifying 15 different autoantibodies in voluntary participating laboratories from their country. We analyzed the impact on the assay performances of the type of immunoassay, the number of measurements used to calculate the coefficient of variation (CVs), the nature and the autoantibody level of the internal quality control (IQC). Data were obtained from 64 laboratories from 15 European countries between February and October 2021. We analyzed 686 and 1,331 values of intra-and inter-run CVs, respectively. Both CVs were significantly dependent on: The method of immunoassay, the level of IQC with higher imprecision observed when the antibody levels were lower than 2-fold the threshold for positivity, and the nature of the IQC with commercial IQCs having lower CVs than patients-derived IQCs. Our analyses also show that the type of autoantibody has low impact on the assay' performances and that 15 measurements are sufficient to establish reliable intra-and inter-run variations. This study provides for the first time an international repository yielding values of intra-and inter-run variation for quantitative autoantibody assays. These data could be useful for ISO 15189 accreditation requirements and will allow clinical diagnostic laboratories to assure quality of patient results.
  •  
6.
  • Kattge, Jens, et al. (författare)
  • TRY plant trait database - enhanced coverage and open access
  • 2020
  • Ingår i: Global Change Biology. - : Wiley-Blackwell. - 1354-1013 .- 1365-2486. ; 26:1, s. 119-188
  • Tidskriftsartikel (refereegranskat)abstract
    • Plant traits-the morphological, anatomical, physiological, biochemical and phenological characteristics of plants-determine how plants respond to environmental factors, affect other trophic levels, and influence ecosystem properties and their benefits and detriments to people. Plant trait data thus represent the basis for a vast area of research spanning from evolutionary biology, community and functional ecology, to biodiversity conservation, ecosystem and landscape management, restoration, biogeography and earth system modelling. Since its foundation in 2007, the TRY database of plant traits has grown continuously. It now provides unprecedented data coverage under an open access data policy and is the main plant trait database used by the research community worldwide. Increasingly, the TRY database also supports new frontiers of trait-based plant research, including the identification of data gaps and the subsequent mobilization or measurement of new data. To support this development, in this article we evaluate the extent of the trait data compiled in TRY and analyse emerging patterns of data coverage and representativeness. Best species coverage is achieved for categorical traits-almost complete coverage for 'plant growth form'. However, most traits relevant for ecology and vegetation modelling are characterized by continuous intraspecific variation and trait-environmental relationships. These traits have to be measured on individual plants in their respective environment. Despite unprecedented data coverage, we observe a humbling lack of completeness and representativeness of these continuous traits in many aspects. We, therefore, conclude that reducing data gaps and biases in the TRY database remains a key challenge and requires a coordinated approach to data mobilization and trait measurements. This can only be achieved in collaboration with other initiatives.
  •  
7.
  • Sack, Ulrich, et al. (författare)
  • Quality and best practice in medical laboratories : specific requests for autoimmunity testing
  • 2020
  • Ingår i: Autoimmun Highlights. - : Springer. - 2038-0305 .- 2038-3274. ; 11:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Special conditions associated with laboratory autoimmune testing are not well compatible with recent developments in regulatory frameworks such as EN/ISO 15189 accreditation or in vitro diagnostic medical device regulation (IVD-R). In addition, international recommendations, guidelines and disease criteria are poorly defined with respect to requirements on autoantibody testing. Laboratory specialists from Austria, Belgium, Croatia, Estonia, Finland, France, Germany, Greece, Hungary, Italy, Norway, Poland, Portugal, South Africa, Spain, Sweden, Switzerland, and The Netherlands collected information, reported national experience, and identified quality issues in relation to autoantibody testing that require consensus on interpretation of the regulatory frameworks and guidelines. This process has been organized by the European Autoimmunity Standardisation Initiative (EASI). By identifying the critical items and looking for a consensus, our objective was to define a framework for, in particular, EN/ISO accreditation purposes. Here, we present a review of current publications and guidelines in this field to unify national guidelines and deliver in this way a European handout on quality control and accreditation for laboratories involved in autoantibody testing. We focus on quality items that can be checked during accreditation visits. Despite various local varieties, we encountered an overwhelming dedication to quality assurance in all contributing countries.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy