1. |
- Blomström-Lundqvist, Carina, 1954-, et al.
(författare)
-
European Heart Rhythm Association (EHRA) international consensus document on how to prevent, diagnose, and treat cardiac implantable electronic device infections : endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), the Latin American Heart Rhythm Society (LAHRS), International Society for Cardiovascular Infectious Diseases (ISCVID) and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS)
- 2020
-
Ingår i: Europace. - : Oxford University Press (OUP). - 1099-5129 .- 1532-2092. ; 22:4, s. 515-516ag
-
Tidskriftsartikel (refereegranskat)abstract
- Pacemakers, implantable cardiac defibrillators, and cardiac resynchronization therapy devices are potentially life-saving treatments for a number of cardiac conditions, but are not without risk. Most concerning is the risk of a cardiac implantable electronic device (CIED) infection, which is associated with significant morbidity, increased hospitalizations, reduced survival, and increased healthcare costs. Recommended preventive strategies such as administration of intravenous antibiotics before implantation are well recognized. Uncertainties have remained about the role of various preventive, diagnostic, and treatment measures such as skin antiseptics, pocket antibiotic solutions, anti-bacterial envelopes, prolonged antibiotics post-implantation, and others. Guidance on whether to use novel device alternatives expected to be less prone to infections and novel oral anticoagulants is also limited, as are definitions on minimum quality requirements for centres and operators and volumes. Moreover, an international consensus document on management of CIED infections is lacking. The recognition of these issues, the dissemination of results from important randomized trials focusing on prevention of CIED infections, and observed divergences in managing device-related infections as found in an European Heart Rhythm Association worldwide survey, provided a strong incentive for a 2019 International State-of-the-art Consensus document on risk assessment, prevention, diagnosis, and treatment of CIED infections.
|
|
2. |
- Blomström-Lundqvist, Carina, et al.
(författare)
-
European Heart Rhythm Association (EHRA) international consensus document on how to prevent, diagnose, and treat cardiac implantable electronic device infections-endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), the Latin American Heart Rhythm Society (LAHRS), International Society for Cardiovascular Infectious Diseases (ISCVID) and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS). : European Heart Rhythm Association (EHRA) international consensus document on how to prevent, diagnose, and treat cardiac implantable electronic device infections.
- 2020
-
Ingår i: European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. - : Oxford University Press (OUP). - 1873-734X. ; 57:1, s. 1-31
-
Tidskriftsartikel (refereegranskat)abstract
- Pacemakers, implantable cardiac defibrillators, and cardiac resynchronization therapy devices are potentially life-saving treatments for a number of cardiac conditions, but are not without risk. Most concerning is the risk of a cardiac implantable electronic device (CIED) infection, which is associated with significant morbidity, increased hospitalizations, reduced survival, and increased healthcare costs. Recommended preventive strategies such as administration of intravenous antibiotics before implantation are well recognized. Uncertainties have remained about the role of various preventive, diagnostic, and treatment measures such as skin antiseptics, pocket antibiotic solutions, anti-bacterial envelopes, prolonged antibiotics post-implantation, and others. Guidance on whether to use novel device alternatives expected to be less prone to infections and novel oral anticoagulants is also limited, as are definitions on minimum quality requirements for centres and operators and volumes. Moreover, an international consensus document on management of CIED infections is lacking. The recognition of these issues, the dissemination of results from important randomized trials focusing on prevention of CIED infections, and observed divergences in managing device-related infections as found in an European Heart Rhythm Association worldwide survey, provided a strong incentive for a 2019 International State-of-the-art Consensus document on risk assessment, prevention, diagnosis, and treatment of CIED infections.
|
|
3. |
- Bongiorni, Maria G, et al.
(författare)
-
2018 EHRA expert consensus statement on lead extraction : recommendations on definitions, endpoints, research trial design, and data collection requirements for clinical scientific studies and registries: endorsed by APHRS/HRS/LAHRS
- 2018
-
Ingår i: Europace. - : Oxford University Press (OUP). - 1099-5129 .- 1532-2092. ; 20:7
-
Tidskriftsartikel (refereegranskat)abstract
- The number of cardiac implantable electronic device (CIED) implantations has increased over recent years as a result of population growth, increasing life expectancy, adoption of guidelines, and better access to healthcare. Transvenous lead extraction (TLE), as a part of an overall lead management strategy, has also been increasing, not only as a consequence of this growth, but also because of increasing rates of infection, lead failure, awareness of indications for lead management, and development of extraction tools. Clinical research is essential for understanding efficacy and risks of TLE, which has important implications regarding decision-making and therapeutic strategies in patients who are candidates for this procedure. Data on TLE have mainly come from retrospective series, with variable reporting of endpoints. Recently, the ELECTRa registry conducted by the European Heart Rhythm Association (EHRA), has reported the largest prospective experience on lead extraction published to date in 3555 patients recruited from 19 European countries. There remain unresolved issues, which is a strong incentive for conducting further specifically-designed clinical trials to answer important questions in this area. In addition to clinical studies, national registries are potentially useful for evaluating epidemiology of TLE as well as for quality control and understanding resource implications. Standardization of definitions and reporting of parameters are paramount in order to analyse, compare, and pool data for scientific purposes. Expert consensus statements on lead extraction have been published by the Heart Rhythm Society (HRS) in 2009 and 2017, and by EHRA in 2012. Experience from the ELECTRa registry has been valuable for identifying challenges faced with conducting scientific studies in this field, and provides a framework for future endeavours.This writing group has been commissioned by EHRA to provide recommendations for designing scientific studies, reports and registries relating to lead extraction.
|
|
4. |
- Traykov, Vassil, et al.
(författare)
-
Clinical practice and implementation of guidelines for the prevention, diagnosis and management of cardiac implantable electronic device infections : results of a worldwide survey under the auspices of the European Heart Rhythm Association
- 2019
-
Ingår i: Europace. - : Oxford University Press. - 1099-5129 .- 1532-2092. ; 21:8, s. 1270-1279
-
Tidskriftsartikel (refereegranskat)abstract
- AIMS: Cardiac implantable electronic device (CIED) infection rates are increasing. Worldwide compliance and disparities to published guidelines for the prevention, diagnosis and management of these conditions are not well elucidated. The purpose of this survey, therefore, was to clarify these issues through an inquiry to arrhythmia-related associations and societies worldwide.METHODS AND RESULTS: A questionnaire comprising 15 questions related to CIED infections was distributed among members of seven arrhythmia societies worldwide. A total of 234 centres in 62 countries reported implantation rates of which 159 (68.0%) performed more than 200 device implantations per year and 14 (6.0%) performed fewer than 50 implantations per year. The reported rates of CIED infections for 2017 were ≤2% in 78.7% of the centres, while the infection rates exceeded 5% in 7.8% of the centres. Preventive measures for CIED infection differed from published recommendations and varied among different regions mainly in terms of pocket irrigation and administering post-operative antimicrobial therapy the use of which was reported by 39.9% and 44% of the respondents, respectively. Antibacterial envelopes were used by 37.7% of the respondents in selected circumstances. In terms of pocket infection management, 62% of the respondents applied complete system removal as an initial step. Diagnostic pocket needle aspiration and pocket surgical debridement were reported by 15.8% and 11.8% of centres, respectively.CONCLUSION: Clinical practices for prevention and management of CIED do not fully comply with current recommendations and demonstrate considerable regional disparities. Further education and programmes for improved implementation of guidelines are mandatory.
|
|