1.
  •  
2.
  • Dyverfeldt, Petter, et al. (författare)
  • Magnetic Resonance Measurement of Turbulent Kinetic Energy for the Estimation of Irreversible Pressure Loss in Aortic Stenosis
  • 2013
  • Ingår i: JACC Cardiovascular Imaging. - : Elsevier. - 1936-878X .- 1876-7591. ; 6:1, s. 64-71
  • Tidskriftsartikel (refereegranskat)abstract
    • ObjectivesThe authors sought to measure the turbulent kinetic energy (TKE) in the ascending aorta of patients with aortic stenosis and to assess its relationship to irreversible pressure loss.BackgroundIrreversible pressure loss caused by energy dissipation in post-stenotic flow is an important determinant of the hemodynamic significance of aortic stenosis. The simplified Bernoulli equation used to estimate pressure gradients often misclassifies the ventricular overload caused by aortic stenosis. The current gold standard for estimation of irreversible pressure loss is catheterization, but this method is rarely used due to its invasiveness. Post-stenotic pressure loss is largely caused by dissipation of turbulent kinetic energy into heat. Recent developments in magnetic resonance flow imaging permit noninvasive estimation of TKE.MethodsThe study was approved by the local ethics review board and all subjects gave written informed consent. Three-dimensional cine magnetic resonance flow imaging was used to measure TKE in 18 subjects (4 normal volunteers, 14 patients with aortic stenosis with and without dilation). For each subject, the peak total TKE in the ascending aorta was compared with a pressure loss index. The pressure loss index was based on a previously validated theory relating pressure loss to measures obtainable by echocardiography.ResultsThe total TKE did not appear to be related to global flow patterns visualized based on magnetic resonance–measured velocity fields. The TKE was significantly higher in patients with aortic stenosis than in normal volunteers (p < 0.001). The peak total TKE in the ascending aorta was strongly correlated to index pressure loss (R2 = 0.91).ConclusionsPeak total TKE in the ascending aorta correlated strongly with irreversible pressure loss estimated by a well-established method. Direct measurement of TKE by magnetic resonance flow imaging may, with further validation, be used to estimate irreversible pressure loss in aortic stenosis.
  •  
3.
  •  
4.
  • Sigovan, Monica, et al. (författare)
  • Comparison of four-dimensional flow parameters for quantification of flow eccentricity in the ascending aorta
  • 2011
  • Ingår i: Journal of Magnetic Resonance Imaging. - : John Wiley & Sons. - 1053-1807 .- 1522-2586. ; 34:5, s. 1226-1230
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose:To compare quantitative parameters for assessing the degree of eccentric systolic blood flow in the ascending thoracic aorta (AsAo).Materials and Methods:Forty-one patients were studied with three-dimensional (3D), cine phase-contract MRI (4D Flow). Analysis was performed at peak systole for a cross-sectional plane in the AsAo just distal to the sinotubular junction. AsAo flow was graded as normal, mildly, or markedly eccentric based on qualitative visual assessment. For quantitative analysis, flow jet angle and normalized flow displacement from the vessel center were calculated.Results:Patients with normal AsAo systolic flow (n = 25) had an average flow jet angle of 13.7 degrees and flow displacement 0.04. These parameters were significantly elevated for patients with mild eccentric systolic flow (n = 6): 24.6 degrees (P = 0.012) and 0.12 (P = 0.001), respectively. However, for patients with marked eccentric flow (n = 10), only flow displacement was significantly elevated compared with the mild eccentric group (0.18; P = 0.04); flow angle was 25.7 degrees.Conclusion:Flow displacement is a more reliable quantitative parameter for measuring eccentric AsAo systolic flow than flow jet angle, and should be evaluated in studies investigating the role of eccentric flow in the promotion of aortic pathology. 
  •  
5.
  • Sigovan, Monica, et al. (författare)
  • Extended 3D approach for quantification of abnormal ascending aortic flow
  • 2015
  • Ingår i: Magnetic Resonance Imaging. - : Elsevier. - 0730-725X .- 1873-5894. ; 33:5, s. 695-700
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Flow displacement quantifies eccentric flow, a potential risk factor for aneurysms in the ascending aorta, but only at a single anatomic location. The aim of this study is to extend flow displacement analysis to 3D in patients with aortic and aortic valve pathologies. Methods: 43 individuals were studied with 4DFlow MRI in 6 groups: healthy, tricuspid aortic valve (TAV) with aortic stenosis (AS) but no dilatation, TAV with dilatation but no AS, and TAV with both AS and dilatation, BAV without AS or dilatation, BAV without AS but with dilation. The protocol was approved by our institutional review board, and informed consent was obtained. Flow displacement was calculated for multiple planes along the ascending aorta, and 2D and 3D analyses were compared. Results: Good correlation was found between 2D flow displacement and both maximum and average 3D values (r greater than 0.8). Healthy controls had significantly lower flow displacement values with all approaches (p less than 0.05). The highest flow displacement was seen with stenotic TAV and aortic dilation (0.24 +/- 0.02 with maximum flow displacement). The 2D approach underestimated the maximum flow displacement by more than 20% in 13 out of 36 patients (36%). Conclusions: The extended 3D flow displacement analysis offers a more comprehensive quantitative evaluation of abnormal systolic flow in the ascending aorta than 2D analysis. Differences between patient subgroups are better demonstrated, and maximum flow displacement is more reliably assessed.
  •  