  • Siiskonen, T., et al. (författare)
  • Establishing the European diagnostic reference levels for interventional cardiology
  • 2018
  • Ingår i: Physica medica (Testo stampato). - : ELSEVIER SCI LTD. - 1120-1797 .- 1724-191X. ; 54, s. 42-48
  • Tidskriftsartikel (refereegranskat)abstract
    • Interventional cardiac procedures may be associated with high patient doses and therefore require special attention to protect the patients from radiation injuries such as skin erythema, cardiovascular tissue reactions or radiation-induced cancer. In this study, patient exposure data is collected from 13 countries (37 clinics and nearly 50 interventional rooms) and for 10 different procedures. Dose data was collected from a total of 14,922 interventional cardiology procedures. Based on these data European diagnostic reference levels (DRL) for air kerma-area product are suggested for coronary angiography (CA, DRL = 35 Gy cm(2)), percutaneous coronary intervention (PCI, 85 Gy cm(2)), transcatheter aortic valve implantation (TAVI, 130 Gy cm(2)), electrophysiological procedures (12 Gy cm(2)) and pacemaker implantations Pacemaker implantations were further divided into single-chamber (2.5 Gy cm(2)) and dual chamber (3.5 Gy cm(2)) procedures and implantations of cardiac resynchronization therapy pacemaker (18 Gy cm(2)). Results show that relatively new techniques such as TAVI and treatment of chronic total occlusion (CTO) often produce relatively high doses, and thus emphasises the need for use of an optimization tool such as DRL to assist in reducing patient exposure. The generic DRL presented here facilitate comparison of patient exposure in interventional cardiology.
  •  
3.
  •  
4.
  •  
5.
  • Ullman, Gustav, et al. (författare)
  • On the extent of quantum noise limitation in digital chest radiography
  • 2004
  • Rapport (övrigt vetenskapligt/konstnärligt)abstract
    • The aim for this work was to study to what extent the detection of nodules is quantum noise limited, based on the combined results from a nodule-detection clinical trial and a Monte Carlo computational model of a digital chest imaging system. The Monte Carlo computer program computes measures of physical image quality such as image contrast, C and signalto-noise ratio, SNR for nodules of any size. A computed radiography (CR) imaging system used simulated. The patient anterior-posterior thickness was 25 cm and nodules with diameters between 1-40 mm were included. The image contrast and SNR was calculated for 1600 (40x40) positions in the chest image and averaged over five anatomical regions of interest (lateral pulmonary, retrocardial, hilar, lower- and upper mediastinal regions). Threshold contrasts for each region, Cth, corresponding to Az=0.80 for detecting a 10 mm nodule, were deduced from the clinical trial. A threshold is also used for the quantum noise signal-to-noise ratio, SNRth. The model computes the diameter of a disk-shaped object that is required to comply with the two criteria: SNR≥SNRth and C≥Cth. A system is said to be quantum noise limited when the nodule size required to fulfil both criteria is not limited by the contrast but by the SNR. The required nodule diameter is largest in the hilar region (25 mm) and smallest in the lateral pulmonary region (11 mm). When the threshold SNRth=25 is used, the lower mediastinal region is quantum noise limited already at low speed classes (S>100). The hilar region is never quantum noise limited at realistic speed classes (S<1000). The accuracy of this model will be tested in the future by more sophisticated modelling of anatomical background and noise in the SNR-expression.
  •  
6.
  • Hunt, R, et al. (författare)
  • Monte Carlo simulation of a mammographic test phantom
  • 2005
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 432-435
  • Tidskriftsartikel (refereegranskat)abstract
    • A test phantom, including a wide range of mammographic tissue equivalent materials and test details, was imaged on a digital mammographic system. In order to quantify the effect of scatter on the contrast obtained for the test details, calculations of the scatter-to-primary ratio (S/P) have been made using a Monte Carlo simulation of the digital mammographic imaging chain, grid and test phantom. The results show that the S/P values corresponding to the imaging conditions used were in the range 0.084-0.126. Calculated and measured pixel values in different regions of the image were compared as a validation of the model and showed excellent agreement. The results indicate the potential of Monte Carlo methods in the image quality-patient dose process optimisation, especially in the assessment of imaging conditions not available on standard mammographic units. © The Author 2005. Published by Oxford University Press. All rights reserved.
  •  
7.
  •  
8.
  • Tapiovaara, M, et al. (författare)
  • How should low-contrast detail detectability be measured in fluoroscopy?
  • 2004
  • Ingår i: Medical physics (Lancaster). - : Wiley. - 0094-2405. ; 31:9, s. 2564-2576
  • Tidskriftsartikel (refereegranskat)abstract
    • The relationship and precision of four methods for measuring the low-contrast detail detectability in fluoroscopic imaging were studied. These included the physical measurement of the accumulation rate of the square of the signal-to-noise ratio (SNRrate2), two-alternative forced-choice (2-AFC) experiments, sixteen-alternative forced-choice (16-AFC) experiments and subjective determination of the threshold contrast. The precision and sensitivity of the threshold contrast measurement were seen to be modest in the constancy testing of fluoroscopic equipment: only large changes in system performance could be reliably detected by that method. The measurement of the SNRrate2 is suggested instead. The relationship between the results of the various methods were studied, and it was found that human performance can be related to SNRrate2 by introducing the concept of the effective image information integration time (teff). When measured for an unlimited observation time, it depicts the saturation of human performance in detecting a static low-contrast detail in dynamic image noise. Here, teff was found to be about 0.6 s in 2-AFC tests and 0.3 s in 16-AFC tests. © 2004 American Association of Physicists in Medicine.
  •  
9.
  • Tingberg, Anders, et al. (författare)
  • Comparison of two methods for evaluation of image quality of lumbar spine radiographs
  • 2004
  • Ingår i: Progress in Biomedical Optics and Imaging - Proceedings of SPIE. - : SPIE. - 1605-7422. ; 5372, s. 251-262
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • Purpose To evaluate the image quality of clinical radiographs with two different methods, and to find correlations between the two methods. Methods Based on fifteen lumbar spine radiographs, two new sets of images were created. A hybrid image set was created by adding two distributions of artificial lesions to each original image. The image quality parameters spatial resolution and noise were manipulated and a total of 210 hybrid images were created. A set of 105 disease-free images was created by applying the same combinations of spatial resolution and noise to the original images. The hybrid images were evaluated with the free-response forced error experiment (FFE) and the normal images with visual grading analysis (VGA) by nine experienced radiologists. Results The VGA study showed that images with low noise are preferred over images with higher noise levels. The alteration of the MTF had a limited influence on the VGA score. For the FFE study the visibility of the lesions was independent of the spatial resolution and the noise level. Discussion In this study we found no correlation between the two methods, probably because the detectability of the artificial lesions was not influenced by the manipulations of noise level and resolution. Hence, the detection of lesions in lumbar spine radiography may not be a quantum-noise limited task. The results show the strength of the VGA technique in terms of detecting small changes in the two image quality parameters. The method is more robust and has a higher statistical power than the ROC related method and could therefore, in some cases, be more suitable for use in optimization studies.
  •  