SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Sandstedt Mårten 1972 ) "

Sökning: WFRF:(Sandstedt Mårten 1972 )

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Sandstedt, Mårten, 1972- (författare)
  • Computed Tomography of the Coronary Arteries : Developmental and Prognostic Investigations
  • 2020
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Computed tomography (CT) is an increasingly used modality for investigations of patients with suspected coronary artery disease (CAD). Technical advances could improve diagnostic accuracy and lead to clinical workflow improvements. Also, more prognostic information can optimize clinical follow-up strategies and treatments.The general aim of this thesis was to explore the use of CT for CAD investigations. Three studies aimed to examine new technologies, including the evaluation of an on-site, computed tomography-based fractional flow reserve (CT-FFR) software (study I), the evaluation of an AI-based, calcium scoring computed tomography (CSCT) software (study III), and the evaluation of an photon-counting detector (PCD)-CT (study IV). One study aimed to evaluate the long-term prognostic value of coronary computed tomography angiography (CCTA) in symptomatic patients with no history of CAD (study II).The software evaluation studies (study I and III) and the prognostic study (study II) utilized CT data from clinical patients, while the PCD-CT evaluation study (study IV) used CT data from cadaveric specimens. The performances of both software programs were compared with standard references, being represented by fractional flow reserve (FFR) measurements (study I), and coronary artery calcification (CAC) scores from a semi-automatic software (study III), respectively. The PCD-CT performance on CAC quantification was compared with corresponding results from an energy integrating detector (EID)-CT, using micro-CT as the standard reference (study IV). The prognostic study merged registries to identify major adverse cardiac events (MACE), having a follow-up time of up to 7.5 years (study II).The CT-FFR and CSCT software correlation and agreement to corresponding standard references were good and excellent, respectively. Also, both software programs had time-saving potential (study I and III). The CAC quantification was more accurate using PCD-CT than EID-CT (study IV). The prognosis was excellent in patients with normal coronary arteries, and progressively impaired in non-obstructive and obstructive CAD (study II).The results in this thesis convey developmental, technical CT technology advances for CAD investigations. In addition, prognostic follow-up data is communicated. The results may benefit patients by an increased accuracy in the CT evaluation of CAD and can contribute to improve clinical follow-up strategies. Furthermore, the results suggest possibilities to improve the workflow in clinical radiology, which potentially could impact health care costs.
  •  
3.
  • Sandstedt, Mårten, 1972-, et al. (författare)
  • Evaluation of an AI-based, automatic coronary artery calcium scoring software
  • 2020
  • Ingår i: European Radiology. - : Springer. - 0938-7994 .- 1432-1084. ; 30:3, s. 1671-1678
  • Tidskriftsartikel (refereegranskat)abstract
    • ObjectivesTo evaluate an artificial intelligence (AI)–based, automatic coronary artery calcium (CAC) scoring software, using a semi-automatic software as a reference.MethodsThis observational study included 315 consecutive, non-contrast-enhanced calcium scoring computed tomography (CSCT) scans. A semi-automatic and an automatic software obtained the Agatston score (AS), the volume score (VS), the mass score (MS), and the number of calcified coronary lesions. Semi-automatic and automatic analysis time were registered, including a manual double-check of the automatic results. Statistical analyses were Spearman’s rank correlation coefficient (⍴), intra-class correlation (ICC), Bland Altman plots, weighted kappa analysis (κ), and Wilcoxon signed-rank test.ResultsThe correlation and agreement for the AS, VS, and MS were ⍴ = 0.935, 0.932, 0.934 (p < 0.001), and ICC = 0.996, 0.996, 0.991, respectively (p < 0.001). The correlation and agreement for the number of calcified lesions were ⍴ = 0.903 and ICC = 0.977 (p < 0.001), respectively. The Bland Altman mean difference and 1.96 SD upper and lower limits of agreements for the AS, VS, and MS were − 8.2 (− 115.1 to 98.2), − 7.4 (− 93.9 to 79.1), and − 3.8 (− 33.6 to 25.9), respectively. Agreement in risk category assignment was 89.5% and κ = 0.919 (p < 0.001). The median time for the semi-automatic and automatic method was 59 s (IQR 35–100) and 36 s (IQR 29–49), respectively (p < 0.001).ConclusionsThere was an excellent correlation and agreement between the automatic software and the semi-automatic software for three CAC scores and the number of calcified lesions. Risk category classification was accurate but showing an overestimation bias tendency. Also, the automatic method was less time-demanding.Key Points• Coronary artery calcium (CAC) scoring is an excellent candidate for artificial intelligence (AI) development in a clinical setting.• An AI-based, automatic software obtained CAC scores with excellent correlation and agreement compared with a conventional method but was less time-consuming.
  •  
4.
  • Skoog, Susann, et al. (författare)
  • A prospective study comparing the quality of coronary computed tomography angiography images from photon counting and energy integrating detector systems
  • 2023
  • Ingår i: Acta Radiologica. - : SAGE PUBLICATIONS LTD. - 0284-1851 .- 1600-0455. ; 64:11, s. 2957-2966
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: As guidelines endorse the use of computed tomography (CT) for examining coronary artery disease (CAD), it is important to compare the advantages and disadvantages of the novel photon counting detector CT (PCD-CT) technology with the established energy integrating detector CT (EID-CT). Purpose: To compare the image quality of coronary computed tomography angiography (CCTA) and the Agatston scores (AS) derived from EID-CT and PCD-CT. Material and Methods: In this prospective observational study, 28 patients underwent clinical calcium score and CCTA scans on an EID-CTand a PCD-CT scanner. CCTA images were qualitatively analyzed by five observers using visual grading characteristics. The correlation and agreement of the AS were assessed using Spearmans rank correlation and Bland-Altman plots. Results: This qualitative analyses demonstrated a high fraction of " good" or "excellent" ratings for the image criteria in both CT systems. The sharpness of the distal lumen and image quality regarding motion artifacts were rated significantly higher for EID-CT (P < 0.05). However, the sharpness of coronary calcification was rated significantly higher for PCD-CT (P < 0.05). Spearmans rank correlation and Bland-Altman plots showed good correlation (P = 0.95) and agreement regarding the AS between EID-CT and PCD-CT. Conclusion: Both CT systems exhibited high CCTA image quality. The sharpness of calcifications was rated significantly higher for PCD-CT. A good correlation was observed between the AS derived from the two systems.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy