SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Savin Andrej) "

Sökning: WFRF:(Savin Andrej)

  • Resultat 1-10 av 39
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Boström, Cecilia, et al. (författare)
  • Design proposal of electrical system for linear generator wave power plants
  • 2009
  • Ingår i: 35TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS. - : IEEE. - 9781424446483 - 9781424446506 ; , s. 4180-4185
  • Konferensbidrag (refereegranskat)abstract
    • This paper describes an electrical system layout for a wave power plant connecting linear generators to the grid. The electrical power out from the wave energy converters must be converted before they can be connected to the grid. The conversion is carried out in marine substations that will be placed on the seabed.The paper presents experimental power data from a wave energy converter that has been in operation at the Lysekil research site since March 2006. Moreover, results and analyses from experiments and simulations from tests with the generator connected to a rectifier and filter are presented. A simulation is made to show the difference between having the generator connected to a linear load and a nonlinear load, which would be the case when the generator is connected to the grid.
  •  
3.
  • Boström, Cecilia, et al. (författare)
  • Experimental results from an offshore wave energy converter
  • 2008
  • Ingår i: Volume 6. ; , s. 653-657
  • Konferensbidrag (refereegranskat)abstract
    • Anoffshore wave energy converter (WEC) was successfully launched at theSwedish west coast in the middle of March 2006. TheWEC is based on a permanent magnet linear generator locatedon the ocean floor driven by a point absorber. Ameasuring station has been installed on a nearby island whereall measurements and experiments on the WEC have been carriedout. The output voltage from the generator fluctuates both inamplitude and frequency and must therefore be converted to enablegrid connection. In order to study the voltage conversion, themeasure station was fitted with a six pulse diode rectifierand a capacitive filter during the autumn of 2006. Theobject of this paper is to present a detailed descriptionof the existing wave energy system of the Islandsberg project.Special attention will be given to the power absorption bythe generator when it is connected to a non linearload
  •  
4.
  • Boström, Cecilia, et al. (författare)
  • Experimental Results From an Offshore Wave Energy Converter
  • 2010
  • Ingår i: Journal of Offshore Mechanics and Arctic Engineering-Transactions of The Asme. - : ASME International. - 0892-7219 .- 1528-896X. ; 132:4, s. 041103-
  • Tidskriftsartikel (refereegranskat)abstract
    • An offshore wave energy converter (WEC) was successfully launched at the Swedish west coast in the middle of March 2006. The WEC is based on a permanent magnet linear generator located on the sea floor driven by a point absorber. A measuring station has been installed on a nearby island where all measurements and experiments on the WEC have been carried out. The output voltage from the generator fluctuates both in amplitude and frequency and must therefore be converted to enable grid connection. In order to study the voltage conversion, the measuring station was fitted with a six pulse diode rectifier and a capacitive filter during the autumn of 2006. The object of this paper is to present a detailed description of the Lysekil research site. Special attention will be given to the power absorption by the generator when it is connected to a nonlinear load.
  •  
5.
  • Boström, Cecilia, et al. (författare)
  • Temperature measurements in a linear generator and marine substation for wave power
  • 2010
  • Ingår i: PROCEEDINGS OF THE ASME 29TH INTERNATIONAL CONFERENCE ON OCEAN,   OFFSHORE AND ARCTIC ENGINEERING 2010, VOL 3. - 9780791849118 ; , s. 545-552
  • Konferensbidrag (refereegranskat)abstract
    • This paper analyzes temperature measurements acquired in offshore operation of a wave energy converter array. The three directly driven wave energy converters have linear generators and are connected to a marine substation placed on the seabed. The highly irregular individual linear generator voltages are rectified and added on a common DC-link and inverted to 50 Hz to facilitate future grid-connection. The electrical power is transmitted to shore and converted to heat in a measuring station. First results of temperature measurements on substation components and on the stator of one of the linear generators are presented from operation in linear and in non-linear damping. Results indicate that there might be some convective heat transport in the substation vessel. If high power levels are extracted from the waves, this has to be considered when placing components in the substation vessel to avoid heating from neighbouring components. The results also indicate that the temperature increase in the linear generator stator is very small. Failure due to excessive heating of the stator winding PVC cable insulation is unlikely to occur even in very energetic sea states. Should this conclusion be incorrect, the thermal conductivity between the stator and the hull of the WEC could be enhanced. Another suggested alteration would be to lower the resistive losses by reducing the linear generator current density.
  •  
6.
  • Boström, Cecilia, et al. (författare)
  • Temperature measurements in a linear generator and marine substation for wave power
  • 2012
  • Ingår i: Journal of Offshore Mechanics and Arctic Engineering-Transactions of The Asme. - : ASME International. - 0892-7219 .- 1528-896X. ; 134:2, s. 021901-
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper analyzes temperature measurements acquired in the offshore operation of a wave energy converter array. The three directly driven wave energy converters have linear generators and are connected to a marine substation placed on the seabed. The highly irregular individual linear generator voltages are rectified and added on a common dc-link and inverted to 50 Hz to facilitate future grid-connection. The electrical power is transmitted to shore and converted to heat in a measuring station. The first results of temperature measurements on substation components and on the stator of one of the linear generators are presented based on operation in linear and in nonlinear damping. The results indicate that there might be some convective heat transfer in the substation vessel. If high power levels are extracted from the waves, this has to be considered when placing components in the substation vessel in order to avoid heating from neighboring components. The results also indicate that the temperature increase in the linear generator stator is very small. Failure due to excessive heating of the stator winding polyvinyl chloride cable insulation is unlikely to occur even in very energetic sea states. Should this conclusion be incorrect, the thermal conductivity between the stator and the hull of the wave energy converter could be enhanced. Another suggested alteration is to lower the resistive losses by reducing the linear generator current density.
  •  
7.
  • Chen, WenChuang, et al. (författare)
  • Numerical modelling of a point-absorbing wave energy converter in irregular and extreme waves
  • 2017
  • Ingår i: Applied Ocean Research. - : Elsevier BV. - 0141-1187 .- 1879-1549. ; 63, s. 90-105
  • Tidskriftsartikel (refereegranskat)abstract
    • Based on the Navier-Stokes (RANS) equations, a three-dimensional (3-D) mathematical model for the hydrodynamics and structural dynamics of a floating point-absorbing wave energy converter (WEC) with a stroke control system in irregular and extreme waves is presented. The model is validated by a comparison of the numerical results with the wave tank experiment results of other researchers. The validated model is then utilized to examine the effect of wave height on structure displacements and connection rope tension. In the examined cases, the differences in WEC’s performance exhibited by an inviscid fluid and a viscous fluid can be neglected. Our results also reveal that the differences in behavior predicted by boundary element method (BEM) and the RANS-based method can be significant and vary considerably, depending on wave height.
  •  
8.
  • Dolguntseva, Irina, 1981-, et al. (författare)
  • Risk based estimation of failure in a steel wire used for the wave energy converter connection line
  • 2014
  • Konferensbidrag (refereegranskat)abstract
    • The wave energy converter being developed at Uppsala University is of a point absorber type utilizing heaving motion of waves with a direct driven linear generator power take off. The point absorber, a buoy, is placed on the sea surface and is connected to the translator by a connection line. The connection line service life is of large importance for the lifetime of the entire device. Steel wire used as the connection line should be chosen to withstand loadings with different amplitude and frequency. In the present study, the risk of failure in the connection line is estimated.
  •  
9.
  • Ekergård, Boel, et al. (författare)
  • Axial Force Damper in a Linear Wave Energy Converter
  • 2013
  • Ingår i: Development and Applications of Oceanic Engineering (DAOE). - 2325-3762. ; 2:2, s. 33-38
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents a study on the axial force damper in a wave energy converter. The converter itself consists of a linear generator placed on the ocean floor connected to a buoy at the ocean surface. As the development of the complete system goes forward, the economical perspective becomes more and more important. In order to ensure an economically viable alternative to the electric energy conversion, the costs associated with the use of materials have to be reduced while the survivability of the wave power unit has to be prolonged. The study presented in this paper increases the knowledge on axial forces and illustrates the damping system required to prevent the failure of the hull which houses the generator. The results are aimed to be utilized in the future design of wave energy converters and influence the choice of materials, the total costs and prolong the survivability of the wave energy converters in harsh wave climates.
  •  
10.
  • Ekweoba, Chisom Miriam, 1992- (författare)
  • Hydro-mechanical optimization of a wave energy converter
  • 2022
  • Licentiatavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Wave energy conversion technology has gained popularity due to its potential to be-come one of the most preferred energy sources. Its high energy density and low car-bon footprint have inspired the development of many wave energy converter (WEC) technologies, few of which have made their way to commercialisation, and many are progressing.The Floating Power Plant (FPP) device is a combined floating wind and wave converter. The company, Floating Power Plant, was established in 2004 and has developed and patented a floating device that consists of a semi-submersible that serves as a foundation for a single wind turbine and hosts four wave energy converters (WECs). Each WEC consists of a partially submerged wave absorber whose pitching motion generates energy from incoming waves. The wave absorbers are connected to an oil hydraulic power take-off system located in a dry “engine room” above the free water surface, where the mechanical energy in the absorber is converted to electricity. When undergoing pitching movements, there are interactions between individual wave absorbers and the surrounding platform. This thesis focuses on developing methods to improve the FPP WEC’s hydrodynamic interactions.The first part of this thesis optimises the wave absorber (WA) ballast. An ana-lytical model is developed to enable systematic selection of WA ballast combination with significantly less computational effort when compared with the more conven-tional means, such as using CAD software. The study suggests an algorithm with which the absorbed power and resonance frequency can be improved and adjusted by manipulating the ballasts’ mass, the position of its centre of gravity, placement and inclination of the WA. The proposed method is generic and can be applied to other WEC concepts or submerged bodies in general. The results show the feasibility of designing the absorber ballast to offer passive control for increased wave absorption. It demonstrates the effect of ballast on the WA inclination, resonance frequency and response amplitude operator (RAO).The second part focuses on the optimisation of the FPP platform geometry. The genetic algorithm optimisation technique is implemented to maximise the annual en-ergy produced by the relative pitch motion of the WA to the floating platform. The optimised variables are characteristic lengths of the floating platform, most of which are part of the immediate surrounding walls of the absorber. The objective function is a function of the WA’s annual energy production (AEP) and RAO. Results show the feasibility of improving the hydrodynamic interaction between the floating platform and its integrated wave absorbers for a given wave climate by using a heuristic search technique. The number of iterations to convergence tends towards increased values when considering more optimised variables. It is also observed that the computational time appears to be independent of the number of variables but is significantly impacted by the computational power of the machine used.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 39
Typ av publikation
tidskriftsartikel (17)
konferensbidrag (11)
bokkapitel (6)
samlingsverk (redaktörskap) (3)
doktorsavhandling (1)
licentiatavhandling (1)
visa fler...
visa färre...
Typ av innehåll
refereegranskat (34)
övrigt vetenskapligt/konstnärligt (5)
Författare/redaktör
Savin, Andrej (36)
Leijon, Mats (20)
Svensson, Olle (17)
Strömstedt, Erland (15)
Lindskoug, Patrik (10)
Boström, Cecilia (10)
visa fler...
Waters, Rafael (10)
Lundqvist, Björn (7)
Rahm, Magnus (6)
Lejerskog, Erik (6)
Gravråkmo, Halvar (6)
Engström, Jens (5)
Tyrberg, Simon (5)
Sundberg, Jan (4)
Leijon, Mats, 1958 (4)
Haikonen, Kalle (4)
Eriksson, Mikael (3)
Bolund, Björn (3)
Strömstedt, Erland, ... (3)
Baudoin, Antoine (2)
Temiz, Irina, 1981- (2)
Ekström, Rickard (2)
Lindqvist, Björn (2)
Ekergård, Boel (2)
Dolguntseva, Irina, ... (2)
Johansson, Tobias (1)
Bernhoff, Hans (1)
Karlberg, Magnus (1)
Li, Wei (1)
Gustafsson, Stefan (1)
Boström, C (1)
Langhamer, Olivia (1)
Isberg, Jan (1)
Thorburn, Karin (1)
Parwal, Arvind (1)
Castellucci, Valeria (1)
Svensson, Olle, 1967 ... (1)
Ågren, Olov (1)
Francisco, Francisco (1)
Björklöf, Daniel (1)
Leijon, Mats, Profes ... (1)
Stålberg, Magnus (1)
Zhang, Yongliang (1)
Hai, Ling (1)
Chatzigiannakou, Mar ... (1)
Ulvgård, Liselotte (1)
Chen, Wenchuang (1)
Li, Wei, 1984- (1)
Danielsson, Oskar (1)
Ekweoba, Chisom Miri ... (1)
visa färre...
Lärosäte
Uppsala universitet (30)
Lunds universitet (9)
Stockholms universitet (1)
Språk
Engelska (39)
Forskningsämne (UKÄ/SCB)
Teknik (15)
Samhällsvetenskap (9)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy