SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Schuerle S.) "

Sökning: WFRF:(Schuerle S.)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Dheman, K., et al. (författare)
  • ImpediSense:A long lasting wireless wearable bio-impedance sensor node
  • 2021
  • Ingår i: Sustainable Computing. - : Elsevier Inc.. - 2210-5379 .- 2210-5387. ; 30
  • Tidskriftsartikel (refereegranskat)abstract
    • Bio-impedance is a method to assess the body composition safely, non-invasively and inexpensively. This method finds application for assessing body fluid and body composition for multiple disease scenarios in clinical environments and for at-home monitoring of chronic ailments. Bio-impedance sensors require higher power than most other bio-signal acquisition systems due to need of high frequency current and voltage management. Currently used bio-impedance devices are bulky due to incorporation of large batteries and cannot be used for long term monitoring, especially for wearable applications. This limits the widespread implementation of bio-impedance measurement devices. We present the design and implementation of a wireless wearable bio-impedance sensor node, ImpediSense, which has a low power system design that achieves long duration operability without compromising on sensor measurement accuracy and precision. Experimental evaluation show a battery life of several months for measuring bio-impedance with power duty cycling every 1 min over ten frequencies in the range of 10 kHz–100 kHz, using a small form factor 250 mA h Li-ion battery. The lifetime is achieved due to several power optimization implemented in system design of hardware and firmware resulting in active power of 53 mW and idle power of 15.7 μW. Additionally, the presented sensor node shows high performance in terms of accuracy of impedance measurement with an error less than 1.5 % and precision of 0.6 Ω when measuring tetrapolar bio-impedance of the human body. With the inclusion of a small sized battery, ImpediSense has a compact form factor with dimensions 3 cm × 1.8 cm × 0.6 cm, making it more conducive for incorporation in wearable systems. © 2021
  •  
2.
  • Dheman, K., et al. (författare)
  • Wireless, Artefact Aware Impedance Sensor Node for Continuous Bio-Impedance Monitoring
  • 2020
  • Ingår i: IEEE Transactions on Biomedical Circuits and Systems. - : Institute of Electrical and Electronics Engineers Inc.. - 1932-4545 .- 1940-9990. ; 14:5, s. 1122-1134
  • Tidskriftsartikel (refereegranskat)abstract
    • Body bio-impedance is a unique parameter to monitor changes in body composition non-invasively. Continuous measurement of bio-impedance can track changes in body fluid content and cell mass and has widespread applications for physiological monitoring. State-of-the-art implementation of bio-impedance sensor devices is still limited for continuous use, in part, due to artefacts arising at the skin-electrode (SE) interface. Artefacts at the SE interface may arise due to various factors such as motion, applied pressure on the electrode surface, changes in ambient conditions or gradual drying of electrodes. This paper presents a novel bio-impedance sensor node that includes an artefact aware method for bio-impedance measurement. The sensor node enables autonomous and continuous measurement of bio-impedance and SE contact impedance at ten frequencies between 10 kHz to 100 kHz to detect artefacts at the SE interface. Experimental evaluation with SE contact impedance models using passive 2R1C electronic circuits and also with non-invasive in vivo measurements of SE contact impedance demonstrated high accuracy (with maximum error less than 1.5%) and precision of 0.6 ω. The ability to detect artefacts caused by motion, vertically applied pressure and skin temperature changes was analysed in proof of concept experiments. Low power sensor node design achieved with 50mW in active mode and only 143 μW in sleep mode estimated a battery life of 90 days with a 250 mAh battery and duty-cycling impedance measurements every 60 seconds. Our method for artefact aware bio-impedance sensing is a step towards autonomous and unobtrusive continuous bio-impedance measurement for health monitoring at-home or in clinical environments. © 2007-2012 IEEE.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Mayer, P. (2)
Magno, M. (2)
Dheman, K. (2)
Schuerle, S. (2)
Eggimann, M. (1)
Lärosäte
Mittuniversitetet (2)
Språk
Engelska (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy