  • Regoli, François, et al. (författare)
  • Impact of anticoagulation therapy on outcomes in patients with cardiac implantable resynchronization devices undergoing transvenous lead extraction : A substudy of the ESC-EHRA EORP ELECTRa (European Lead Extraction ConTRolled) Registry
  • 2019
  • Ingår i: Cardiovascular Electrophysiology. - : Wiley. - 1045-3873 .- 1540-8167. ; 30:7, s. 1086-1095
  • Tidskriftsartikel (refereegranskat)abstract
    • INTRODUCTION: Little data are available on anticoagulation (AC) management in patients with cardiac resynchronization (CRT) devices who undergo transvenous lead extraction (TLE) procedure. We investigated the impact of AC on periprocedural complications in CRT patients undergoing TLE, enrolled in the ESC-EHRA European Lead Extraction ConTrolled (ELECTRa) registry.METHODS AND RESULTS: All CRT patients treated with TLE enrolled in the registry were considered. Perioperative AC management was left to the discretion of the Center. Major and minor intraprocedural and postprocedural complications were compared between patients without AC (Gp1) and patients with AC (Gp2). Regression analyses were performed to identify predictors of complications for Gp2. Out of 734 CRT pts, 328 (44.7%) were under AC (Gp2). Patients from Gp2 presented lower LVEF (Gp2 32.5 ± 10.9 vs Gp1 34.5 ± 11.9%; P = 0.03), more advanced heart failure disease (NYHA III/IV: Gp2 42.0 vs Gp1 31.5%; P = 0.02), and renal impairment (Gp2 39.0 vs Gp1 24.3%; P < 0.001). Perioperative regimens included AC interruption (Gp2A: n = 169, 51.5%), "bridging" (Gp2B: n = 135, 41.2%), or continued AC (Gp2C: n = 24, 7.3%). TLE complete success rates (98% in both groups) and major complication rates were comparable for both groups; minor bleeding events were more frequent in Gp2 (5.5%) compared to Gp1 (2.5%; P = 0.051). No independent predictors were identified for Gp2, but minor complications were associated with "bridging" approach (Gp2B: 16 events vs Gp2A/C: 9 events; P = 0.020).CONCLUSION: CRT patients treated with TLE under AC were more compromised but did not present more major complications compared to patients without AC. More minor complications were associated with "bridging" AC regimen.
  •  
2.
  • Segreti, Luca, et al. (författare)
  • Procedural outcomes associated with transvenous lead extraction in patients with abandoned leads : an ESC-EHRA ELECTRa (European Lead Extraction ConTRolled) Registry Sub-Analysis.
  • 2019
  • Ingår i: Europace. - : Oxford University Press (OUP). - 1099-5129 .- 1532-2092. ; 21:4, s. 645-654
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: The decision to abandon or extract superfluous leads remains controversial. We sought to compare procedural outcome of patients with and without abandoned leads undergoing transvenous lead extraction (TLE).Methods and results: An analysis of the ESC-EHRA European Lead Extraction ConTRolled ELECTRa registry was conducted. Patients were stratified into two groups based on the presence (Group 1) or absence (Group 2) of abandoned leads at the time for extraction. Out of 3508 TLE procedures, 422 patients (12.0%) had abandoned leads (Group 1). Group 1 patients were older and more likely to have implantable cardioverter-defibrillator devices, infection indication (78.8% vs. 49.8%), and vegetations (24.6% vs. 15.3%). Oldest lead dwelling time was longer in Group 1 (10.9 vs. 6.3 years) as was the number of extracted leads per patient (3.2 vs. 1.7). Manual traction failure (94.5% vs. 78.8%), powered sheath use (50.7% vs. 28.4%), and femoral approach were higher in Group 1 (P < 0.0001). Procedural success rate and clinical success (89.8% vs. 96.6%, P < 0.0001) were lower in Group 1. Major complication including deaths (5.5% vs. 2.3%, P = 0.0007) and procedure related major complications (3.3% vs. 1.4%, P = 0.0123) were higher in Group 1. The presence of abandoned leads at the time of TLE was an independent predictor of clinical failure [odds ratio (OR) 2.31, confidence interval (CI) 1.57-3.40] and complications [OR 1.69, CI 1.22-2.35]. receiver-operating characteristic curve analysis showed a dwell time threshold of 9 years for radiological failure and major complications.Conclusions: Previously abandoned leads at the time of TLE were associated with increased procedural complexity, clinical failure, and major complication, which may have important implications for future studies regarding managing of lead failures.
  •  
3.
  • Zucchelli, Giulio, et al. (författare)
  • Major cardiac and vascular complications after transvenous lead extraction : acute outcome and predictive factors from the ESC-EHRA ELECTRa (European Lead Extraction ConTRolled) registry
  • 2019
  • Ingår i: Europace. - : Oxford University Press (OUP). - 1099-5129 .- 1532-2092. ; 21:5, s. 771-780
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: We aimed at describing outcomes and predictors of cardiac avulsion or tear (CA/T) with tamponade and vascular avulsion or tear (VA/T) after transvenous lead extraction (TLE) in the ESC-EHRA European Lead Extraction ConTRolled (ELECTRa) registry.Methods and results: A total of 3555 consecutive patients of whom 3510 underwent TLE at 73 centres in 19 European countries were enrolled. Among 58 patients (1.7%) with procedure-related major complications, 49 (84.5%) patients (30 CA/T and 19 VA/T) presented cardiovascular complications requiring pericardiocentesis, chest tube positioning and/or surgical repair. The mortality was 20% in patients with tamponade due to CA/T and 31.6% in patients with VA/T. Pericardiocentesis as first manoeuvre followed by rescue surgical repair was highly effective in case of CA/T (93.8%). At multivariate analysis, CA/T with tamponade was more common in RIATA lead extraction, female patients, leads with a mean dwelling time more than 10 years, and when ≥3 leads were extracted or multiple sheaths required. Occlusion or critical stenosis of superior venous access and the leads mean dwelling time more than 10 years were independent predictors for VA/T, while mechanical dilatation was an independent predictor of a lower incidence of this complication as compared to the use of powered sheaths.Conclusions: In the ELECTRa registry, RIATA lead extraction and superior venous access occlusion/thrombosis are two new independent predictors for cardiac tamponade and major vascular complications, respectively. The use of mechanical sheaths seems to be associated with a lower incidence of VA/T. A strategy of pericardiocentesis followed by a rescue surgical approach seems to be reasonable in order to treat a CA/T with tamponade.
  •  