SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Sekiya S.) "

Sökning: WFRF:(Sekiya S.)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abe, K., et al. (författare)
  • J-PARC Neutrino Beamline Upgrade Technical Design Report
  • 2019
  • Rapport (refereegranskat)abstract
    • In this document, technical details of the upgrade plan of the J-PARC neutrino beamline for the extension of the T2K experiment are described. T2K has proposed to accumulate data corresponding to 2×1022 protons-on-target in the next decade, aiming at an initial observation of CP violation with 3σ or higher significance in the case of maximal CP violation. Methods to increase the neutrino beam intensity, which are necessary to achieve the proposed data increase, are described.
  •  
2.
  • Abe, K., et al. (författare)
  • Neutron tagging following atmospheric neutrino events in a water Cherenkov detector
  • 2022
  • Ingår i: Journal of Instrumentation. - : Institute of Physics (IOP). - 1748-0221 .- 1748-0221. ; 17:10
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the development of neutron-tagging techniques in Super-Kamiokande IV using a neural network analysis. The detection efficiency of neutron capture on hydrogen is estimated to be 26%, with a mis-tag rate of 0.016 per neutrino event. The uncertainty of the tagging efficiency is estimated to be 9.0%. Measurement of the tagging efficiency with data from an Americium-Beryllium calibration agrees with this value within 10%. The tagging procedure was performed on 3,244.4 days of SK-IV atmospheric neutrino data, identifying 18,091 neutrons in 26,473 neutrino events. The fitted neutron capture lifetime was measured as 218 +/- 9 mu s.
  •  
3.
  • De Leoz, M. L. A., et al. (författare)
  • NIST Interlaboratory Study on Glycosylation Analysis of Monoclonal Antibodies: Comparison of Results from Diverse Analytical Methods
  • 2020
  • Ingår i: Molecular & Cellular Proteomics. - 1535-9476. ; 19:1, s. 11-30
  • Tidskriftsartikel (refereegranskat)abstract
    • A broad-based interlaboratory study of glycosylation profiles of a reference and modified IgG antibody involving 103 reports from 76 laboratories. Glycosylation is a topic of intense current interest in the development of biopharmaceuticals because it is related to drug safety and efficacy. This work describes results of an interlaboratory study on the glycosylation of the Primary Sample (PS) of NISTmAb, a monoclonal antibody reference material. Seventy-six laboratories from industry, university, research, government, and hospital sectors in Europe, North America, Asia, and Australia submitted a total of 103 reports on glycan distributions. The principal objective of this study was to report and compare results for the full range of analytical methods presently used in the glycosylation analysis of mAbs. Therefore, participation was unrestricted, with laboratories choosing their own measurement techniques. Protein glycosylation was determined in various ways, including at the level of intact mAb, protein fragments, glycopeptides, or released glycans, using a wide variety of methods for derivatization, separation, identification, and quantification. Consequently, the diversity of results was enormous, with the number of glycan compositions identified by each laboratory ranging from 4 to 48. In total, one hundred sixteen glycan compositions were reported, of which 57 compositions could be assigned consensus abundance values. These consensus medians provide community-derived values for NISTmAb PS. Agreement with the consensus medians did not depend on the specific method or laboratory type. The study provides a view of the current state-of-the-art for biologic glycosylation measurement and suggests a clear need for harmonization of glycosylation analysis methods.
  •  
4.
  • Saito, T. R., et al. (författare)
  • Studies of three-and four-body hypernuclei with heavy-ion beams, nuclear emulsions and machine learning
  • 2023
  • Ingår i: Journal of Physics, Conference Series. - : Institute of Physics (IOP). - 1742-6588 .- 1742-6596. ; 2586
  • Tidskriftsartikel (refereegranskat)abstract
    • Interests on few-body hypernuclei have been increased by recent results of experiments employing relativistic heavy ion beams. Some of the experiments have revealed that the lifetime of the lightest hypernucleus, hypertriton, is significantly shorter than 263 ps which is expected by considering the hypertriton to be a weakly-bound system. The STAR collaboration has also measured the hypertriton binding energy, and the deduced value is contradicting to its formerly known small binding energy. These measurements have indicated that the fundamental physics quantities of the hypertriton such as its lifetime and binding energy have not been understood, therefore, they have to be measured very precisely. Furthermore, an unprecedented Lambda nn bound state observed by the HypHI collaboration has to be studied in order to draw a conclusion whether or not such a bound state exists. These three-body hypernuclear states are studied by the heavy-ion beam data in the WASA-FRS experiment and by analysing J-PARC E07 nuclear emulsion data with machine learning.
  •  
5.
  • Tanaka, Y. K., et al. (författare)
  • Search for eta '-mesic nuclei using (p,d) reaction with FRS/Super-FRS at GSI/FAIR
  • 2020
  • Ingår i: Journal of Physics, Conference Series. - : IOP Publishing. - 1742-6588 .- 1742-6596. ; 1643
  • Tidskriftsartikel (refereegranskat)abstract
    • We plan a semi-exclusive measurement of the C-12(p,dp) reaction to search for eta'-mesic nuclei, aiming at investigating in-medium properties of the eta'-meson. We employ a 2.5 GeV proton beam impinging on a carbon target to produce eta'-mesic C-11 nuclei via the C-12(p,d)eta'circle times C-11 reaction. Using coincidence measurements of the forward going deuterons, important for missing-mass spectroscopy, and decay protons emitted from the eta'-mesic nuclei for event selection will provide a high experimental sensitivity to observe eta'-mesic nuclei. We will perform the measurements by combining the WASA detector system with the fragment separator FRS at GSI and also with the Super-FRS at FAIR in the future. The plan of the experiments and the present status are reported.
  •  
6.
  • Saito, T. R., et al. (författare)
  • The WASA-FRS project at GSI and its perspective
  • 2023
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section B. - : Elsevier. - 0168-583X .- 1872-9584. ; 542, s. 22-25
  • Tidskriftsartikel (refereegranskat)abstract
    • A novel technique to study bound states of exotic hadrons in subatomic nuclei, such as hypernuclei and mesic nuclei, has been developed by employing the Fragment Separator FRS and the WASA central detector at GSI. Two experiments, S447 for studying light hypernuclei, especially hypertriton and a Ann bound state, and S490 for searching for ri' mesic-nuclei, were recently performed. Data analyses are currently in progress, and light charged particles such as protons and x & PLUSMN; are clearly observed and identified in the both experiments. For S447, light nuclear fragments that can also be residual nuclei from decays of hypernuclei of interests have been analysed by the FRS, and a momentum resolution, Ap/p, of 5 x 10-4 has been achieved. Further data analyses are to be completed. The WASA-FRS project will be continued and extended with the FRS at FAIR Phase 0, and upgrading of the WASA magnet and detectors is currently in progress. Furthermore, construction of a larger detector system with the Super-FRS at FAIR Phase 1 is also under consideration.
  •  
7.
  • Tanaka, Y. K., et al. (författare)
  • WASA-FRS EXPERIMENTS IN FAIR PHASE-0 AT GSI
  • 2023
  • Ingår i: ACTA PHYSICA POLONICA B PROCEEDINGS SUPPLEMENT. - : Jagiellonian University.
  • Konferensbidrag (refereegranskat)abstract
    • We have developed a new and unique experimental setup integrating the central part of the Wide Angle Shower Apparatus (WASA) into the Fragment Separator (FRS) at GSI. This combination opens up possibilities of new experiments with high-resolution spectroscopy at forward 0 and measurements of light decay particles with nearly full solid-angle acceptance in coincidence. The first series of the WASA-FRS experiments have been successfully carried out in 2022. The developed experimental setup and two physics experiments performed in 2022 including the status of the preliminary data analysis are introduced.
  •  
8.
  • Luyten, F. P., et al. (författare)
  • Toward classification criteria for early osteoarthritis of the knee
  • 2018
  • Ingår i: Seminars in Arthritis and Rheumatism. - : Elsevier BV. - 0049-0172. ; 47:4, s. 457-463
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: To propose draft classification criteria for early stage osteoarthritis (OA) of the knee for use in a primary care setting. Methods: A group of basic scientists, physician-scientists, rheumatologists, orthopedic surgeons, and physiotherapists in a workshop setting discussed potential classification criteria for early osteoarthritis of the knee. The workshop was divided into sessions around relevant topics with short state of the art presentations followed by breakout sessions, consensus discussions, and consolidation into a consensus document. Results: Three classes of criteria were agreed: (1) Pain, symptoms/signs, self-reported function, and quality of life using tools such as KOOS: scoring ≤85% in at least 2 out of these 4 categories; (2) Clinical examination: at least 1 present out of joint line tenderness or crepitus; (3) Knee radiographs: Kellgren & Lawrence (KL) grade of 0 or 1. MRI is at present not recommended as an aid to identify or define early OA in routine clinical practice or primary care, in light of the absence of validated consensus criteria and the high population prevalence of structural joint changes detected by this method. Biomarkers may have future utility in early OA classification, but no individual or set of biomarkers is yet robust enough. Conclusion: Based on our consensus proposal, draft classification criteria for early OA of the knee for use in clinical studies should include patient reported outcomes such as pain and function, together with clinical signs and KL grade 0-1 on radiographs.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy