SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Simonsson Pär 1963 ) "

Sökning: WFRF:(Simonsson Pär 1963 )

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Rydler, Karl-Erik, et al. (författare)
  • High accuracy low-voltage ac-dc transfer standards
  • 1994
  • Ingår i: Proceedings of Conference on Precision Electromagnetic Measurements Digest. - 0780319842 ; , s. 382-383
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • Micropotentiometers and resistive dividers are designed using thick-film chip resistors. Two methods to determine the ac-dc transfer difference at low voltages using micropotentiometers and resistive dividers are described. At 10 mV, the difference between the two methods are less than 10 ppm at 1 kHz and less than 100 ppm at 1 MHz.
  •  
2.
  • Simonsson, Pär, 1963-, et al. (författare)
  • A comparison of power measuring systems
  • 1997
  • Ingår i: IEEE Transactions on Instrumentation and Measurement. - : Institute of Electrical and Electronics Engineers (IEEE). - 0018-9456 .- 1557-9662. ; 46:2, s. 423-425
  • Tidskriftsartikel (refereegranskat)abstract
    • An automatic zero-power-factor standard has been designed and compared with a digital sampling wattmeter standard. The agreement of the two power measuring standards at 120 V, 5 A, and zero power factor is within a few uW/VA. The paper describes the standards, the phase errors and uncertainties of the two standards
  •  
3.
  • Simonsson, Pär, 1963-, et al. (författare)
  • Level dependence of AC-DC transfer devices
  • 1999
  • Ingår i: IEEE Transactions on Instrumentation and Measurement. - : Institute of Electrical and Electronics Engineers (IEEE). - 0018-9456 .- 1557-9662. ; 48:2, s. 395-398
  • Tidskriftsartikel (refereegranskat)abstract
    • A new method based on summing of phase controlled AC voltages makes it possible to compare thermal voltage converters with a ratio of 2:1 without introducing any error due to level dependence. The method is used to determine the level dependence of thermal voltage converters up to 1 kV and 100 kHz. The level dependence is compared to the change of AC-DC transfer difference due to power dissipation in the range resistor and due to DC-effects in the thermal converter. The results for two investigated TVC's indicate that the power dissipation is the only cause of level dependence in the range resistor of a high voltage TVC.
  •  