SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Siosteen AK) "

Sökning: WFRF:(Siosteen AK)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abu-Zidan, FM, et al. (författare)
  • Establishment of a teaching animal model for sonographic diagnosis of trauma
  • 2004
  • Ingår i: Journal of Trauma. - 0022-5282 .- 1529-8809. ; 56:1, s. 99-104
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Ultrasound is widely accepted as a valuable diagnostic tool for detecting intra-abdominal and intrathoracic bleeding in trauma patients. Nevertheless, many doctors are reluctant to use it because they do not have sufficient training. This study aimed to define intraabdominal and intrathoracic fluid volumes that can be detected by sonography and their relation to fluid width in pigs to establish a clinically relevant animal model for teaching and training. Methods: Different volumes of normal saline were infused into the abdomen (50-2,000 mL) and chest (25-250 mL) in five anesthetized pigs. The maximum width of fluid as detected by ultrasound was recorded. The right upper quadrant, left upper quadrant, pelvis, and right paracolic section of the abdomen and right pleural cavity were studied. An experienced radiologist performed the studies. The effects on respiratory and cardiovascular functions were evaluated. Results: The sonographic findings in the pig were similar to those in humans. Up to 50 mL of intra-abdominal fluid and up to 25 mL of intrathoracic fluid could be detected by ultrasound. There was a significant correlation between the volume infused and the fluid width detected. The respiratory and cardiovascular monitoring of the animals showed that the infused intrathoracic volumes mimicked a survivable hemothorax. Conclusion: The pig may serve as an excellent clinically relevant model with which to teach surgeons detection of different volumes of intra-abdominal and intrathoracic fluids. The value of this model as an educational tool has yet to be tested.
  •  
2.
  •  
3.
  •  
4.
  • Rahbin, N, et al. (författare)
  • Detection and characterization of focal liver lesions with contrast-enhanced ultrasonography in patients with hepatitis C-induced liver cirrhosis
  • 2008
  • Ingår i: Acta radiologica (Stockholm, Sweden : 1987). - : SAGE Publications. - 1600-0455 .- 0284-1851. ; 49:3, s. 251-257
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Hepatitis C virus (HCV)-associated liver cirrhosis provides a major preneoplastic condition for hepatocellular carcinoma (HCC). Ultrasonography (US) is usually used for screening of HCC, but needs improvement. Purpose: To assess whether use of a second-generation ultrasound contrast agent can improve characterization of focal liver lesions and detection of HCC in HCV-infected patients with liver cirrhosis. Material and Methods: In total, 96 US studies in 49 HCV-infected patients with liver cirrhosis were performed. The patients were first examined with a baseline US. After this, a diagnostic decision was made and recorded. The patients were then re-examined with contrast-enhanced ultrasound (CEUS), and the diagnostic triage was repeated. The patients were followed up for at least 1 year. Results: On baseline US, indeterminate focal lesions were found in 27 examinations. After CEUS, a confident diagnosis of HCC was made in eight of these examinations. In an additional eight US examinations, diagnosis of regenerative/dysplastic noduli was established. In one patient with no detectable focal lesion at baseline examination, an indeterminate malignant lesion was detected with CEUS. This lesion was further investigated with computed tomography and diagnosed as HCC. Conclusion: Our study indicates that the use of CEUS significantly improves diagnostic confidence. CEUS improves the detection of HCC in patients with HCV-induced liver cirrhosis. Also, CEUS makes it possible to rule out malignancy in many cases where baseline US shows indeterminate focal lesions. In low-endemic countries, the use of CEUS in screening for HCC may be considered.
  •  
5.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy