SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Skalak R) "

Sökning: WFRF:(Skalak R)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Brånemark, Rickard, 1960, et al. (författare)
  • An in-vivo method for biomechanical characterization of bone-anchored implants.
  • 1998
  • Ingår i: Medical engineering & physics. - 1350-4533. ; 20:3, s. 216-9
  • Tidskriftsartikel (refereegranskat)abstract
    • Experimental equipment for in-vivo registrations of pull-out load vs displacement, applied torque vs angle of rotation, and lateral load vs lateral displacement has been developed. The set-up is designed for testing three implants inserted in a row and osseointegrated in, for instance, the proximal tibia of the beagle dog. The details of the set-up are described and considerations of the stress distributions are reported.
  •  
2.
  • Brånemark, Rickard, 1960, et al. (författare)
  • Biomechanical characterization of osseointegration: an experimental in vivo investigation in the beagle dog.
  • 1998
  • Ingår i: Journal of orthopaedic research : official publication of the Orthopaedic Research Society. - : Wiley. - 0736-0266. ; 16:1, s. 61-9
  • Tidskriftsartikel (refereegranskat)abstract
    • This study reports the results of torsion tests, pull-out tests, and lateral loading tests on osseointegrated commercially pure titanium fixtures. The tests were performed in vivo on six beagle dogs. Three fixtures, each with a diameter of 3.7 mm, were installed bilaterally in the tibia of each animal. The mean maximal pull-out load was 1.55 kN (n = 4), the mean maximal lateral transverse load was 0.21 kN (n = 2), the mean maximal lateral axial load was 0.18 kN (n = 2), the mean breakpoint torque was 0.31 Nm (n = 3), and the mean maximal torque was 0.43 Nm (n = 3). The torsion test revealed an almost immediate plastic deformation of the interface between the implant and bone; this indicates that although the contact between the bone and the implant is close, there is no strong bond, at least not in shear. The major transfer of load from the implant to the surrounding bone tissue must therefore depend on the design of the implant. A histological evaluation with measurements of the amount of bone in contact with the fixtures was performed. By the use of the histological and mechanical data, it is possible to estimate shear stresses in bone tissue (pull-out test) and in the interface (torque test). The mean maximal shear stress in bone tissue in the pull-out tests was 100 MPa (n = 4); the mean shear stress in the interface was 4.3 MPa (n = 3) in the torsion tests at the breakpoint torque and was 6.0 MPa (n = 3) at the maximal torque. It was also possible to estimate the shear modulus of elasticity in the pull-out and torque tests. The mean shear modulus in pull-out was 119 MPa (n = 4), and the mean apparent shear modulus in torsion was 9 kPa (n = 3) for an assumed interface thickness of 100 nm and was 86 kPa (n = 3) for an assumed interface thickness of 1,000 nm.
  •  
3.
  • Brånemark, Rickard, 1960, et al. (författare)
  • Osseointegration and rigid fixation.
  • 1992
  • Ingår i: Rigid fixation of the craniomaxillofacoas skeleton. eds Yaremchuk MJ, Gruss JS, Manson PN.. - : Butterworts-Heinemann Publ. ; , s. 275-279
  • Bokkapitel (övrigt vetenskapligt/konstnärligt)
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy