  • Eichenlaub, Manuel, et al. (författare)
  • Comparator Data Characteristics and Testing Procedures for the Clinical Performance Evaluation of Continuous Glucose Monitoring Systems
  • 2024
  • Ingår i: Diabetes Technology & Therapeutics. - : Mary Ann Liebert. - 1520-9156 .- 1557-8593. ; 26:4, s. 263-275
  • Tidskriftsartikel (refereegranskat)abstract
    • Comparing the performance of different continuous glucose monitoring (CGM) systems is challenging due to the lack of comprehensive guidelines for clinical study design. In particular, the absence of concise requirements for the distribution of comparator (reference) blood glucose (BG) concentrations and their rate of change (RoC), that are used to evaluate CGM performance, impairs comparability. For this article, several experts in the field of CGM performance testing have collaborated to propose characteristics of the distribution of comparator measurements that should be collected during CGM performance testing. Specifically, it is proposed that at least 7.5% of comparator BG concentrations are <70 mg/dL (3.9 mmol/L) and >300 mg/dL (16.7 mmol/L), respectively and that at least 7.5% of BG-RoC combinations indicate fast BG changes with impending hypo- or hyperglycemia, respectively. These proposed characteristics of the comparator data can facilitate the harmonization of testing conditions across different studies and CGM systems and ensure that the most relevant scenarios representing real-life situations are established during performance testing. In addition, a study protocol and testing procedure for the manipulation of glucose levels is suggested that enables the collection of comparator data with these characteristics. This work is an important step towards establishing a future standard for the performance evaluation of CGM systems.
  •  
2.
  • Freckmann, Guido, et al. (författare)
  • Clinical Performance Evaluation of Continuous Glucose Monitoring Systems : A Scoping Review and Recommendations for Reporting
  • 2023
  • Ingår i: Journal of Diabetes Science and Technology. - : Sage Publications. - 1932-2968. ; 17:6, s. 1506-1526
  • Forskningsöversikt (refereegranskat)abstract
    • The use of different approaches for design and results presentation of studies for the clinical performance evaluation of continuous glucose monitoring (CGM) systems has long been recognized as a major challenge in comparing their results. However, a comprehensive characterization of the variability in study designs is currently unavailable. This article presents a scoping review of clinical CGM performance evaluations published between 2002 and 2022. Specifically, this review quantifies the prevalence of numerous options associated with various aspects of study design, including subject population, comparator (reference) method selection, testing procedures, and statistical accuracy evaluation. We found that there is a large variability in nearly all of those aspects and, in particular, in the characteristics of the comparator measurements. Furthermore, these characteristics as well as other crucial aspects of study design are often not reported in sufficient detail to allow an informed interpretation of study results. We therefore provide recommendations for reporting the general study design, CGM system use, comparator measurement approach, testing procedures, and data analysis/statistical performance evaluation. Additionally, this review aims to serve as a foundation for the development of a standardized CGM performance evaluation procedure, thereby supporting the goals and objectives of the Working Group on CGM established by the Scientific Division of the International Federation of Clinical Chemistry and Laboratory Medicine.
  •  
3.
  • Lippi, Giuseppe, et al. (författare)
  • Improving quality in the preanalytical phase through innovation, on behalf of the European Federation for Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for Preanalytical Phase (WG-PRE)
  • 2017
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter GmbH. - 1434-6621 .- 1437-4331. ; 55:4, s. 489-500
  • Tidskriftsartikel (refereegranskat)abstract
    • It is now undeniable that laboratory testing is vital for the diagnosis, prognostication and therapeutic monitoring of human disease. Despite the many advances made for achieving a high degree of quality and safety in the analytical part of diagnostic testing, many hurdles in the total testing process remain, especially in the preanalytical phase ranging from test ordering to obtaining and managing the biological specimens. The Working Group for the Preanalytical Phase (WG-PRE) of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) has planned many activities aimed at mitigating the vulnerability of the preanalytical phase, including the organization of three European meetings in the past 7 years. Hence, this collective article follows the previous three opinion papers that were published by the EFLM WGPRE on the same topic, and brings together the summaries of the presentations that will be given at the 4th EFLM-BD meeting “Improving quality in the preanalytical phase through innovation” in Amsterdam, 24–25 March, 2017.
  •  
4.
  • Weykamp, Cas, et al. (författare)
  • The IFCC reference measurement system for HbA(1)C: A 6-year progress report
  • 2008
  • Ingår i: Clinical Chemistry. - : Oxford University Press (OUP). - 0009-9147 .- 1530-8561. ; 54:2, s. 240-248
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The IFCC Reference Measurement System for hemoglobin (Hb)A(1)c (IFCC-RM) has been developed within the framework of metrologic traceability and is embedded in a network of 14 reference laboratories. This paper describes the outcome of 12 intercomparison studies (periodic evaluations to control essential elements of the IFCC-RM). METHODS: Each study included: unknown samples (to test individual network laboratories); known samples (controls); recently manufactured calibrators (to check calculated assigned value); stored calibrators (to test stability) and a calibration-set (to calibrate the IFCC-RM). The unknown samples are measured by use of the IFCC-RM and the designated comparison methods [DCMs; the National Glycohemoglobin Standardization Program (NGSP) in the US, Japanese Diabetes Society/Japanese Society for Clinical Chemistry (JDS/ JSCC) in Japan, and Mono-S in Sweden] are used to investigate the stability of the Master Equation (ME), the relationship between IFCC-RM and DCMs. RESULTS: A total of 105 IFCC-RM data sets were evaluated: 95 were approved, 5 were not, and for 5 no data were submitted. Trend analysis of the MEs, expressed as change in percentage HbA(1)c per year, revealed 0.000% (NGSP, not significant), -0.030%, (JDS/JSCC; significant) and -0.016% (Mono-S; not significant). Evaluation of long-term performance revealed no systematic change over time; 2 laboratories showed significant bias, 1 poor reproducibility. The mean HbA(1)c determined by laboratories performing mass spectrometry (MS) was the same as the mean determined by laboratories using capillary electrophoresis (CE), but the reproducibility at laboratories using CE was better. One batch of new calibrators was not approved. All stored calibrators were stable. CONCLUSION: A sound reference system is in place to ensure continuity and stability of the analytical anchor for HbA(1)c.
  •  