SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Spiegelberg Jakob) "

Sökning: WFRF:(Spiegelberg Jakob)

  • Resultat 1-10 av 23
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Idrobo, Juan Carlos, et al. (författare)
  • Detecting magnetic ordering with atomic size electron probes
  • 2016
  • Ingår i: ADVANCED STRUCTURAL AND CHEMICAL IMAGING. - : SPRINGER HEIDELBERG. - 2198-0926. ; 2
  • Tidskriftsartikel (refereegranskat)abstract
    • Although magnetism originates at the atomic scale, the existing spectroscopic techniques sensitive to magnetic signals only produce spectra with spatial resolution on a larger scale. However, recently, it has been theoretically argued that atomic size electron probes with customized phase distributions can detect magnetic circular dichroism. Here, we report a direct experimental real-space detection of magnetic circular dichroism in aberration-corrected scanning transmission electron microscopy (STEM). Using an atomic size-aberrated electron probe with a customized phase distribution, we reveal the checkerboard antiferromagnetic ordering of Mn moments in LaMnAsO by observing a dichroic signal in the Mn L-edge. The novel experimental setup presented here, which can easily be implemented in aberration-corrected STEM, opens new paths for probing dichroic signals in materials with unprecedented spatial resolution.
  •  
3.
  • Negi, Devendra Singh, et al. (författare)
  • Proposal for Measuring Magnetism with Patterned Apertures in a Transmission Electron Microscope
  • 2019
  • Ingår i: Physical Review Letters. - : AMER PHYSICAL SOC. - 0031-9007 .- 1079-7114. ; 122:3
  • Tidskriftsartikel (refereegranskat)abstract
    • We propose a magnetic measurement method utilizing a patterned post-sample aperture in a transmission electron microscope. While utilizing electron magnetic circular dichroism, the method circumvents previous needs to shape the electron probe to an electron vortex beam or astigmatic beam. The method can be implemented in standard scanning transmission electron microscopes by replacing the spectrometer entrance aperture with a specially shaped aperture, hereafter called ventilator aperture. The proposed setup is expected to work across the whole range of beam sizes -- from wide parallel beams down to atomic resolution magnetic spectrum imaging.
  •  
4.
  • Rusz, Jan, 1979-, et al. (författare)
  • Fully nonlocal inelastic scattering computations for spectroscopical transmission electron microscopy methods
  • 2017
  • Ingår i: Physical Review B. - 2469-9950 .- 2469-9969. ; 96:24
  • Tidskriftsartikel (refereegranskat)abstract
    • The complex interplay of elastic and inelastic scattering amenable to different levels of approximation constitutes the major challenge for the computation and hence interpretation of TEM-based spectroscopical methods. The two major approaches to calculate inelastic scattering cross sections of fast electrons on crystals—Yoshioka-equations-based forward propagation and the reciprocal wave method—are founded in two conceptually differing schemes—a numerical forward integration of each inelastically scattered wave function, yielding the exit density matrix, and a computation of inelastic scattering matrix elements using elastically scattered initial and final states (double channeling). Here, we compare both approaches and show that the latter is computationally competitive to the former by exploiting analytical integration schemes over multiple excited states. Moreover, we show how to include full nonlocality of the inelastic scattering event, neglected in the forward propagation approaches, at no additional computing costs in the reciprocal wave method. Detailed simulations show in some cases significant errors due to the z-locality approximation and hence pitfalls in the interpretation of spectroscopical TEM results.
  •  
5.
  • Rusz, Jan, 1979-, et al. (författare)
  • Localization of magnetic circular dichroic spectra in transmission electron microscopy experiments with atomic plane resolution
  • 2017
  • Ingår i: Physical Review B. - : AMER PHYSICAL SOC. - 2469-9950 .- 2469-9969. ; 95:17
  • Tidskriftsartikel (refereegranskat)abstract
    • Inelastic electron scattering is a consequence of mostly Coulomb interaction between electrons in the sample and electron beam and, as such, it is a nonlocal event. In atomic resolution experiments, it thus opens the following question: How far is the origin of the inelastic scattering signal that is observed when the electron beam is passing nearby an atomic column or plane? We analyze computationally the delocalization of the magnetic signal in electron magnetic circular dichroism (EMCD) experiments in the so-called three-beam orientation, allowing one to image individual atomic planes. We compare the classical EMCD setup using the double-difference procedure (DD-EMCD) to a recently introduced atomic plane resolution EMCD (APR-EMCD) geometry, assuming the same probe size. We observe a strong localization of the EMCD signal to the closest atomic plane, confirming the potential of EMCD to study an evolution of magnetic properties near surfaces or interfaces with atomic plane resolution. The localization of the EMCD signal is remarkably higher than the localization of the nonmagnetic component of the inelastic scattering cross section. We also analyze double-channeling effects and find them particularly strong for the DD-EMCD method, while for APR-EMCD they appear to be minor. The DD-EMCD signal, on the other hand, appears to be more robust with respect to sample thickness than that of the APR-EMCD.
  •  
6.
  • Rusz, Ján, et al. (författare)
  • Magnetic measurements with atomic-plane resolution
  • 2016
  • Ingår i: Nature Communications. - : Springer Science and Business Media LLC. - 2041-1723. ; 7
  • Tidskriftsartikel (refereegranskat)abstract
    • Rapid development of magnetic nanotechnologies calls for experimental techniques capable of providing magnetic information with subnanometre spatial resolution. Available probes of magnetism either detect only surface properties, such as spin-polarized scanning tunnelling microscopy, magnetic force microscopy or spin-polarized low-energy electron microscopy, or they are bulk probes with limited spatial resolution or quantitativeness, such as X-ray magnetic circular dichroism or classical electron magnetic circular dichroism (EMCD). Atomic resolution EMCD methods have been proposed, although not yet experimentally realized. Here, we demonstrate an EMCD technique with an atomic size electron probe utilizing a probe-corrected scanning transmission electron microscope in its standard operation mode. The crucial element of the method is a ramp in the phase of the electron beam wavefunction, introduced by a controlled beam displacement. We detect EMCD signals with atomic-plane resolution, thereby bringing near-atomic resolution magnetic circular dichroism spectroscopy to hundreds of laboratories worldwide.
  •  
7.
  • Schneider, Sebastian, et al. (författare)
  • Simple method for optimization of classical electron magnetic circular dichroism measurements : The role of structure factor and extinction distances
  • 2018
  • Ingår i: Physical Review Materials. - : AMER PHYSICAL SOC. - 2475-9953. ; 2:11
  • Tidskriftsartikel (refereegranskat)abstract
    • Electron magnetic circular dichroism (EMCD), the electron wave analog of x-ray magnetic circular dichroism (XMCD), allows for the element specific measurement of the spin and orbital magnetic moments with up to nanometer resolution. However, due to dynamical diffraction effects, the signal-to-noise ratios of EMCD spectra are often very low. We describe a simple set of rules, how to set up a geometry for a classical EMCD experiment on an arbitrary crystal structure to get a maximum dichroic signal. The procedure is based on an evaluation of the structure factor and extinction distances. Proof-of-concept simulations and experiments on a FeGe crystal present a successful test of these guidelines.
  •  
8.
  • Spiegelberg, Jakob, et al. (författare)
  • A multislice theory of electron scattering in crystals including backscattering and inelastic effects
  • 2015
  • Ingår i: Ultramicroscopy. - : Elsevier BV. - 0304-3991 .- 1879-2723. ; 159, s. 11-18
  • Tidskriftsartikel (refereegranskat)abstract
    • In the framework of the slice transition operator technique, a general multislice theory for electron scattering in crystals is developed. To achieve this generalization, we combine the approaches for inelastic scattering derived by Yoshioka [J. Phys. Soc. Jpn. 12, 6 (1957)] and backscattering based on the formalism of Chen and Van Dyck [Ultramicroscopy 70, 29-44 (1997)]. A computational realization of the obtained equations is suggested. The proposed computational scheme is tested on elastic backscattering of electrons, where we consider single backscattering in analogy to the computational scheme proposed by Chen and Van Dyck.
  •  
9.
  •  
10.
  • Spiegelberg, Jakob, et al. (författare)
  • Blind identification of magnetic signals in electron magnetic chiral dichroism using independent component analysis
  • 2018
  • Ingår i: Ultramicroscopy. - : Elsevier BV. - 0304-3991 .- 1879-2723. ; 195, s. 129-135
  • Tidskriftsartikel (refereegranskat)abstract
    • Electron magnetic chiral dichroism (EMCD) is a promising technique to investigate local magnetic structures in the electron microscope. However, recognition of the EMCD signal, or also finding optimal parameter settings for given materials and sample orientations typically requires extensive simulations to aid the experiment. Here, we discuss how modern data processing techniques, in particular independent component analysis, can be used to identify magnetic signals in an unsupervised manner from energy filtered transmission electron microscopy (EFTEM) images. On the background of the recent advent of 4D scanning transmission electron microscopy, we discuss how this data processing may enable simultaneous tracking of all three spatial components of the magnetic momenta for arbitrary materials and several sample orientations without the previous need of complementary simulations.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 23

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy