SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Starck Sven Ake) "

Sökning: WFRF:(Starck Sven Ake)

  • Resultat 1-1 av 1
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ahlander, Britt-Marie, 1954-, et al. (författare)
  • An echo-planar imaging sequence is superior to a steady-state free precession sequence for visual as well as quantitative assessment of cardiac magnetic resonance stress perfusion
  • 2017
  • Ingår i: Clinical Physiology and Functional Imaging. - : Blackwell Publishing. - 1475-0961 .- 1475-097X. ; 37:1, s. 52-61
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: To assess myocardial perfusion, steady-state free precession cardiac magnetic resonance (SSFP, CMR) was compared with gradient-echo-echo-planar imaging (GRE-EPI) using myocardial perfusion scintigraphy (MPS) as reference.METHODS: Cardiac magnetic resonance perfusion was recorded in 30 patients with SSFP and in another 30 patients with GRE-EPI. Timing and extent of inflow delay to the myocardium was visually assessed. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated. Myocardial scar was visualized with a phase-sensitive inversion recovery sequence (PSIR). All scar positive segments were considered pathologic. In MPS, stress and rest images were used as in clinical reporting. The CMR contrast wash-in slope was calculated and compared with the stress score from the MPS examination. CMR scar, CMR perfusion and MPS were assessed separately by one expert for each method who was blinded to other aspects of the study.RESULTS: Visual assessment of CMR had a sensitivity for the detection of an abnormal MPS at 78% (SSFP) versus 91% (GRE-EPI) and a specificity of 58% (SSFP) versus 84% (GRE-EPI). Kappa statistics for SSFP and MPS was 0·29, for GRE-EPI and MPS 0·72. The ANOVA of CMR perfusion slopes for all segments versus MPS score (four levels based on MPS) had correlation r = 0·64 (SSFP) and r = 0·96 (GRE-EPI). SNR was for normal segments 35·63 ± 11·80 (SSFP) and 17·98 ± 8·31 (GRE-EPI), while CNR was 28·79 ± 10·43 (SSFP) and 13·06 ± 7·61 (GRE-EPI).CONCLUSION: GRE-EPI displayed higher agreement with the MPS results than SSFP despite significantly lower signal intensity, SNR and CNR.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-1 av 1
Typ av publikation
tidskriftsartikel (1)
Typ av innehåll
refereegranskat (1)
Författare/redaktör
Brudin, Lars (1)
Ahlander, Britt-Mari ... (1)
Maret, Eva (1)
Starck, Sven-Ake (1)
Engvall, Jan (1)
Lärosäte
Örebro universitet (1)
Linköpings universitet (1)
Jönköping University (1)
Karolinska Institutet (1)
Språk
Engelska (1)
Forskningsämne (UKÄ/SCB)
Teknik (1)
Medicin och hälsovetenskap (1)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy