SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Stegmayr Bernd) "

Sökning: WFRF:(Stegmayr Bernd)

  • Resultat 1-10 av 186
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Forsberg, Ulf, et al. (författare)
  • A high blood level in the air trap reduces microemboli during hemodialysis
  • 2012
  • Ingår i: Artificial Organs. - : Wiley. - 0160-564X .- 1525-1594. ; 36:6, s. 525-529
  • Tidskriftsartikel (refereegranskat)abstract
    • Previous studies have demonstrated the presence of air microemboli in the dialysis circuit and in the venous circulation of the patients during hemodialysis. In vitro studies indicate that a high blood level in the venous air trap reduces the extent of microbubble formation. The purpose of this study was to examine whether air microbubbles can be detected in the patient's access and if so, whether the degree of microbubble formation can be altered by changing the blood level in the venous air trap. This was a randomized, double-blinded, interventional study of 20 chronic hemodialysis patients. The patients were assigned to hemodialysis with either an elevated or a low blood level in the air trap. The investigator and the patient were blinded to the settings. The numbers of microbubbles were measured at the site of the arteriovenous (AV) access for 2 min with the aid of an ultrasonic Doppler device. The blood level in the air trap was then altered to the opposite setting and a new measurement was carried out after an equilibration period of 30 min. Median (range) for the number of microbubbles measured with the high air trap level and the low air trap level in AV access was 2.5 (0-80) compared with 17.5 (0-77), respectively (P = 0.044). The degree of microbubble formation in hemodialysis patients with AV access was reduced significantly if the blood level in the air trap was kept high. The exposure of potentially harmful air microbubbles was thereby significantly reduced. This measure can be performed with no additional healthcare cost.
  •  
3.
  •  
4.
  • Graaff, Reindert, et al. (författare)
  • Skin and Plasma Autofluorescence During Hemodialysis : A Pilot Study
  • 2014
  • Ingår i: Artificial Organs. - : Wiley. - 0160-564X .- 1525-1594. ; 38:6, s. 515-518
  • Tidskriftsartikel (refereegranskat)abstract
    • Skin autofluorescence (AF) is related to the accumulation of advanced glycation end products (AGEs) and is one of the strongest prognostic markers of mortality in hemodialysis (HD) patients. The aim of this pilot study was to investigate whether changes in skin AF appear after a single HD session and if they might be related to changes in plasma AF. Skin and plasma AF were measured before and after HD in 35 patients on maintenance HD therapy (nine women and 26 men, median age 68 years, range 33-83). Median dialysis time was 4h (range 3-5.5). Skin AF was measured noninvasively with an AGE Reader, and plasma AF was measured before and after HD at 460nm after excitation at 370nm. The HD patients had on average a 65% higher skin AF value than age-matched healthy persons (P<0.001). Plasma AF was reduced by 14% (P<0.001), whereas skin AF was not changed after a single HD treatment. No significant influence of the reduced plasma AF on skin AF levels was found. This suggests that the measurement of skin AF can be performed during the whole dialysis period and is not directly influenced by the changes in plasma AF during HD.
  •  
5.
  •  
6.
  • Jonsson, Per, et al. (författare)
  • Response to letter to the editor.
  • 2007
  • Ingår i: Artif Organs. - : Wiley. - 0160-564X. ; 31:12, s. 913-4
  • Tidskriftsartikel (refereegranskat)
  •  
7.
  • Jonsson, Per, et al. (författare)
  • Venous chambers in clinical use for hemodialysis have limited capacity to eliminate microbubbles from entering the return bloodline : an in vitro study
  • 2023
  • Ingår i: Artificial Organs. - : John Wiley & Sons. - 0160-564X .- 1525-1594. ; 47:6, s. 961-970
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: During hemodialysis (HD), blood passes through an extracorporeal circuit (ECC). To prevent air administration to the patient, a venous chamber (chamber) is located before the blood return. Microbubbles (MBs) may pass through the chamber and end up as microemboli in organs such as the brain and heart. This in vitro study investigated the efficacy of various chambers in MB removal.Materials and Methods: The in vitro recirculated setting of an ECC included an FX10 dialyzer, a dextran-albumin solution to mimic blood viscosity and chambers with different flow characteristics in clinical use (Baxter: AK98 and Artis, Fresenius: 5008 and 6008) and preclinical test (Embody: Emboless®). A Gampt BCC200 device measured the presence and size of MBs (20–500 μm). Percentage change of MBs was calculated: ΔMB% = 100*(outlet–inlet)/inlet for each size of MB. Blood pump speed (Qb) was 200 (Qb200) or 300 (Qb300) ml/minute. Wilcoxon paired test determined differences.Results: With Qb200 median ΔMB% reduction was: Emboless −58%, AK98 −24%, Fresenius 5008 −23%, Artis −8%, and Fresenius 6008 ± 0%. With Qb300 ΔMB% was: Emboless −36%, AK98 ± 0%, Fresenius 5008 ± 0%, Artis +25%, and Fresenius 6008 + 21%. The Emboless was superior to all other chambers with Qb200 and Qb300 (p < 0.001). Further, the Emboless with Qb300 still eliminated more MBs than all other chambers with Qb200 (p ≤ 0.003).Conclusion: The results from the present study indicate that flow characteristics of the chamber and the Qb are important factors to limiting exposure of MB to the return bloodline. The Emboless chamber reduced MBs more effective than those chambers in clinical use investigated.
  •  
8.
  • Mörtzell Henriksson, Monica, et al. (författare)
  • Adverse events in apheresis : an update of the WAA registry data
  • 2016
  • Ingår i: Transfusion and apheresis science. - : Elsevier. - 1473-0502 .- 1878-1683. ; 54:1, s. 2-15
  • Forskningsöversikt (refereegranskat)abstract
    • Apheresis with different procedures and devices are used for a variety of indications that may have different adverse events (AEs). The aim of this study was to clarify the extent and possible reasons of various side effects based on data from a multinational registry. The WAA-apheresis registry data focus on adverse events in a total of 50846 procedures in 7142 patients (42% women). AEs were graded as mild, moderate (need for medication), severe (interruption due to the AE) or death (due to AE). More AEs occurred during the first procedures versus subsequent (8.4 and 5.5%, respectively). AEs were mild in 2.4% (due to access 54%, device 7%, hypotension 15%, tingling 8%), moderate in 3% (tingling 58%, urticaria 15%, hypotension 10%, nausea 3%), and severe in 0.4% of procedures (syncope/hypotension 32%, urticaria 17%, chills/fever 8%, arrhythmia/asystole 4.5%, nausea/vomiting 4%). Hypotension was most common if albumin was used as the replacement fluid, and urticaria when plasma was used. Arrhythmia occurred to similar extents when using plasma or albumin as replacement. In 64% of procedures with bronchospasm, plasma was part of the replacement fluid used. Severe AEs are rare. Although most reactions are mild and moderate, several side effects may be critical for the patient. We present side effects in relation to the procedures and suggest that safety is increased by regular vital sign measurements, cardiac monitoring and by having emergency equipment nearby.
  •  
9.
  • Ramsauer, Bernd, et al. (författare)
  • Comparing changes in plasma and skin autofluorescence in low-flux versus high-flux hemodialysis
  • 2015
  • Ingår i: International Journal of Artificial Organs. - : SAGE Publications. - 0391-3988 .- 1724-6040. ; 38:9, s. 488-493
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Tissue advanced glycation end products (AGE) are increased in hemodialysis (HD) patients, especially those with cardiovascular complications. Skin autofluorescence (skin-AF) can noninvasively estimate the accumulation of AGE in tissue. The aim was to clarify whether HD using a high-flux (HF) dialyzer favors plasma-or skin-AF removal compared to low-flux (LF) dialysis. Material and methods: 28 patients were treated with either an HF-HD or LF-HD but otherwise unchanged conditions in a cross-over design. A glucose containing dialysate was used. Skin-AF was measured noninvasively with an AGE reader before and after HD. Fluorescence (370 nm/465 nm) of plasma (p-AF) was determined as total and nonprotein-bound fractions. Correction for hemoconcentrations were made using the change in serum albumin. Paired and nonpaired statistical analyses were used. Results: Skin-AF was unchanged after LF- and HF-dialysis. Total, free, and protein-bound p-AF was reduced after a single LF-HD by 21%, 28%, and 17%, respectively (P<.001). After HF HD total and free p-AF was reduced by 5% and 15%, respectively (P<.001), while protein bound values were unchanged. The LF-HD resulted in a more pronounced reduction of p-AF than did HF HD (P<.001). Serum albumin correlated inversely with p-AF in HF-HD. Conclusions: In the dialysis settings used there was no significant change in skin AF after dialysis, with LF or with HF dialysis. Although only limited reduction in plasma fluorescence was observed, this was more pronounced when performing LF dialysis. These data are not in overwhelming support of the use of HF dialysis in the setting used in this study.
  •  
10.
  • Ramsauer, Bernd, 1954- (författare)
  • Glucose degradation products in patients on hemodialysis : interventional studies
  • 2016
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Hemodialysis (HD) is the most frequently used treatment for end-stage renal disease. Despite all efforts to improve the outcomes, the mortality of patients on HD is still high, and this especially is related to cardiovascular diseases (CVD). Glucose degradation products accumulate in plasma and tissue as a result of oxidative stress in these patients. Such accumulation is strongly related to the risk of developing CVD. Tissue deposits of advanced glycation end products (AGE) can be easily assessed by a skin autofluorescence (SAF) technique. SAF is one of the strongest prognostic markers of mortality in HD patients. The aim of this thesis is to examine whether intervention on HD treatment can reduce the load of AGE of these patients.The aim of the first study was to investigate whether changes in SAF appear after a single HD session and if they might be related to changes in plasma AF. Skin and plasma AF (PAF) were measured before and after HD in 35 patients on maintenance HD therapy. Median dialysis time was 4 h (range 3-5.5). SAF was measured noninvasively with an AGE Reader, and plasma AF was measured before and after HD. The HD patients had on average a 65% higher SAF value than age-matched healthy persons (P < 0.001). PAF was reduced by 14% (P < 0.001), whereas SAF was not changed after a single HD treatment. No significant influence of the reduced PAF on SAF levels was found. This suggests that the measurement of SAF can be performed during the whole dialysis period and is not directly influenced by the changes in plasma AF during HD.In study 2 different dialysis filters were compared to clarify whether using a high-flux (HF) dialyzer favors plasma or SAF removal compared to low-flux (LF) dialyzer. Twenty-eight patients were treated with either an HF-HD or LF-HD but otherwise unchanged conditions in a cross-over design. SAF was measured non-invasively with an AGE reader before and after HD. PAF was determined as total and non-protein-bound fractions. Corrections for hemoconcentrations by volume changes were made using the change in serum albumin. Paired and non-paired statistical analyses were used. The different treatments did not change SAF after LF- and HF-dialysis. Total, free, and protein-bound PAF were reduced after a single LF-HD by 21%, 28%, and 17%, respectively (P<.001). After HF-HD total and free PAF was reduced by 5% and 15%, respectively (P<.001), while protein-bound values were unchanged. The LF-HD resulted in a more pronounced reduction of PAF than did HF-HD (P<.001). Serum albumin correlated inversely with PAF in HF-HD. There was no significant change in SAF after dialysis, either with LF or with HF dialysis. Although only limited reductions in PAF were observed, these were more pronounced when performing LF dialysis. These data are not in overwhelming support of the use of HF dialysis in the setting used in this study.In the third study the effect on SAF was investigated using either glucose-containing or glucose-free dialysate. SAF and PAF were measured in patients on HD during standard treatment with a glucose-containing dialysate (n=24). After that, the patients were switched to a glucose-free dialysate for a 2 week period, and new measurements were performed on PAF and SAF.There was an increase of pre-dialysis SAF measured at the beginning of the study compared with the values one month later (as in study 4). By comparing pre- and post-dialysis values there was a significant decrease of SAF only when using glucose-free dialysate. Free PAF decreased independently whether glucose-containing or glucose-free dialysate was used. The important finding was that increase in SAF seemed possible to slow down using glucose-free dialysate.Study 4 was performed to investigate whether there are seasonal variations in SAF on a HD population. SAF was measured non-invasively with an AGE Reader in patients on HD at different seasonal periods during one year such as February-May (N=31), May–August (N=28), August–March (N=25). SAF was measured before HD. Paired statistical analyses were performed between each two periods.  Unexpectedly there was at a median 6% increase in SAF during the winter (p=0.004) and a 11% decrease from 4.0 to 3.5 arbitrary units of the SAF during the summer (p<0.001). The study concluded that SAF shows seasonal variation. The cause of these changes could not be clarified. A beneficial effect may be due to extended exposure to sunlight during the summer and/or to different dietary intakes during the seasons.In conclusion, these interventional studies confirmed that PAF is lowered by dialysis. SAF was only decreased by HD when using glucose-free dialysate. SAF was not influenced by a single HD, with glucose-containing dialysate, independent of using HF or LF filters. These data favor glucose-free dialysate as a possible measure to slow down the progress of tissue AGE compared to glucose-containing dialysate. Longitudinal studies will help to clarify this issue further.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 186
Typ av publikation
tidskriftsartikel (152)
forskningsöversikt (17)
doktorsavhandling (11)
annan publikation (6)
Typ av innehåll
refereegranskat (142)
övrigt vetenskapligt/konstnärligt (42)
populärvet., debatt m.m. (2)
Författare/redaktör
Stegmayr, Bernd (118)
Stegmayr, Bernd, 194 ... (36)
Stegmayr, Bernd G (21)
Jonsson, Per (20)
Forsberg, Ulf (15)
Hadimeri, Henrik (14)
visa fler...
Berlin, Gösta (12)
Peters, Björn (11)
Norda, Rut (11)
Sikole, A. (10)
Olivecrona, Gunilla (10)
Griskevicius, A (9)
Sikole, Aleksandar (9)
Arsov, Stefan (8)
Graaff, Reindert (8)
Blaha, M. (8)
Witt, V. (8)
Stegmayr, Christofer (8)
Olivecrona, Thomas (7)
Ramsauer, Bernd (7)
Ott, Michael (7)
Arsov, S. (7)
Rakhorst, G. (7)
Hadimeri, Ursula (7)
Tomaz, J. (7)
Mahmood, Dana, 1965- (7)
Segelmark, Mårten (6)
Nilsson Ekdahl, Kris ... (6)
Nilsson, Bo (6)
Nasic, Salmir (6)
Trajceska, L. (6)
Graaff, R. (6)
Audzijoniene, J. (6)
Bruchfeld, Annette (5)
Mölne, Johan, 1958 (5)
Hadimeri, H (5)
Werneke, Ursula (5)
Nilsson, T (5)
Salander Renberg, El ... (5)
Smit, A. J. (5)
Stenvinkel, Peter (5)
Knutson, Folke (5)
Wikström, Björn (5)
Vrielink, H. (5)
Norda, R. (5)
Lundberg, Lennart (5)
Holmberg, Benny (5)
D'Hondt, A (5)
Axelsson, C.-G. (5)
Näsström, Birgit (5)
visa färre...
Lärosäte
Umeå universitet (173)
Linköpings universitet (28)
Uppsala universitet (21)
Göteborgs universitet (14)
Lunds universitet (11)
Karolinska Institutet (11)
visa fler...
Linnéuniversitetet (4)
Kungliga Tekniska Högskolan (1)
Stockholms universitet (1)
visa färre...
Språk
Engelska (178)
Svenska (4)
Odefinierat språk (4)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (131)
Naturvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy