SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Strombeck Anita) "

Sökning: WFRF:(Strombeck Anita)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abul-Kasim, Kasim, et al. (författare)
  • Interobserver and intraobserver agreement in the evaluation of CT perfusion in ischemic stroke
  • 2009
  • Ingår i: Functional Neurology. - 0393-5264. ; 24:3, s. 139-145
  • Tidskriftsartikel (refereegranskat)abstract
    • Knowledge of interrater reliability in the evaluation of perfusion computed tomography (CTP) studies is very limited even though the method is widely used in the workup of acute stroke. The aims of this study were to estimate the inter- and intraolbserver agreement in the evaluation of CTP data and to evaluate the feasibility of the method. The CTP data of 20 consecutive patients (50% were females) aged 68 +/- 11 years with different categories of acute ischemic stroke were included in this retrospective analysis. Perfusion studies were evaluated independently by six radiologists on two different occasions. The overall inter- and intraolbserver agreement was substantial, showing a K value of 0.65 (95% confidence interval 0.39-0.91). The time required for the post-processing and interpretation ranged from 37 to 460 seconds. Evaluation of manually post-processed CTP data according to the maximum slope model appears to be reliable. Experience and also a short training period increase the reliability of the method and reduce the time needed for delivery of the results to the treating clinician.
  •  
2.
  • Abul-Kasim, Kasim, et al. (författare)
  • Reliability of Low-Radiation Dose CT in the Assessment of Screw Placement After Posterior Scoliosis Surgery, Evaluated With a New Grading System
  • 2009
  • Ingår i: Spine. - 0362-2436. ; 34:9, s. 941-948
  • Tidskriftsartikel (refereegranskat)abstract
    • Study Design. A retrospective study. Objective. To evaluate the reliability of computed tomography (CT) with low radiation dose in the assessment of implant status in patients with adolescent idiopathic scoliosis (AIS). Summary of Background Data. The use of all-pedicle screw construct in scoliosis corrective surgery continues to gain increasing popularity since their introduction 1994 although their use in the thoracic spine carries a potential risk for neurovascular complications. CT is the method widely used to evaluate screw placement. Methods. Retrospective analysis of 46 consecutive low-dose spine CT in patients with AIS after posterior corrective surgery. Status of 809 titanium screws (642 thoracic) was evaluated. The degree of interobserver and intraobserver agreements about implant status was used as an indicator of the reliability of the low-dose spine CT in the assessment of accuracy of pedicle screw insertion. A new grading system has been developed for this purpose. Five types of misplacement have been evaluated: lateral, medial, and anterior cortical perforations; end-plate perforation; and foraminal perforation. Results. The analysis has shown a substantial interobserver and intraobserver agreements (kappa: 0.69 and 0.76, respectively) in differentiating pedicle screws with acceptable placement from screws with partial or total cortical perforation. None of the examinations was subjectively classified as unreliable. Conclusion. The study has shown that low-dose spine CT is a reliable method in evaluating screw placement in patients with AIS after posterior scoliosis surgery with titanium implants, using the here proposed grading system. The new grading system of screw misplacement was feasible and in line with the general agreement about the harmlessness of misplacement with minor pedicle breach. The reliability of low-dose spine CT in evaluation of lateral and medial cortical perforations was substantial. To reduce the radiation load, the postoperative assessment of titanium implants should be performed with low-dose CT.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Abul-Kasim, Kasim (2)
Sundgren, Pia (2)
Maly, Pavel (2)
Strombeck, Anita (2)
Persson, Erik (1)
Ohlin, Acke (1)
visa fler...
Overgaard, Angelica (1)
visa färre...
Lärosäte
Lunds universitet (2)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (2)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy