SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Svanqvist A) "

Sökning: WFRF:(Svanqvist A)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Jana, Somnath, et al. (författare)
  • A setup for element specific magnetization dynamics using the transverse magneto-optic Kerr effect in the energy range of 30-72 eV
  • 2017
  • Ingår i: Review of Scientific Instruments. - : AMER INST PHYSICS. - 0034-6748 .- 1089-7623. ; 88:3
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper, we present a spectrometer that is designed for element-specific and time-resolved transverse magneto-optic Kerr effect experiments at the high-harmonic generation pump-probe facility High Energy Laser Induced Overtone Source (HELIOS) laboratory. HELIOS delivers photons with energies between 30 eV and 72 eV with an overall time resolution of less than 40 fs. The spectrometer is based on a Rowland-circle geometry and allows for simultaneous measurements of all magnetic transition-metal elements. The setup also features easy sample transfer and alignment, and it combines high photon throughput, optimized data acquisition, and a fast switching of the magnetic field at the sample. The spectrometer performance is demonstrated by measuring the ultrafast demagnetization of permalloy. Our data are, for all practical purposes, identical to what have been reported in the earlier high-order harmonic generation work of a similar sample by Mathias et al. [Proc. Natl. Acad. Sci. U.S.A. 109, 4792-4797 (2012)], however, obtained within 15% of the acquisition time compared to their study. Furthermore, our data show a shift of the demagnetization curve of Ni relative to Fe, which has previously been interpreted as a delay of the Ni demagnetization to that of Fe [S. Mathias et al., Proc. Natl. Acad. Sci. U. S. A. 109, 4792-4797 (2012)].
  •  
4.
  • Plogmaker, Stefan, et al. (författare)
  • HELIOS-A laboratory based on high-order harmonic generation of extreme ultraviolet photons for time-resolved spectroscopy
  • 2015
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 86:12
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper, we present the HELIOS (High Energy Laser Induced Overtone Source) laboratory, an in-house high-order harmonic generation facility which generates extreme ultraviolet (XUV) photon pulses in the range of 15-70 eV with monochromatized XUV pulse lengths below 35 fs. HELIOS is a source for time-resolved pump-probe/two-color spectroscopy in the sub-50 fs range, which can be operated at 5 kHz or 10 kHz. An optical parametric amplifier is available for pump-probe experiments with wavelengths ranging from 240 nm to 20 000 nm. The produced XUV radiation is monochromatized by a grating in the so-called off-plane mount. Together with overall design parameters, first monochromatized spectra are shown with an intensity of 2 . 10(10) photons/s (at 5 kHz) in the 29th harmonic, after the monochromator. The XUV pulse duration is measured to be <25 fs after monochromatization.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy