1.
  • Hashimoto, T., et al. (författare)
  • Beamline test of a transition-edge-sensor spectrometer in preparation for kaonic-atom measurements
  • 2017
  • Ingår i: IEEE Transactions on Applied Superconductivity. - 1051-8223. ; 27:4
  • Tidskriftsartikel (refereegranskat)abstract
    • We are developing a new technique to apply transition-edge sensors (TESs) to X-ray spectroscopy of exotic atoms, especially of kaonic atoms. To demonstrate the feasibility of this pioneering project, performance of a TES-based X-ray detector was evaluated in pion- and kaon-beam environments at particle accelerators.We successfully observed X-rays from pionic-carbon atoms with a resolution as good as 7 eV FWHM at 6 keV. Also at a kaon beamline, we confirmed that the TES spectrometer will be able to achieve our resolution goal, 6 eV, in our first scientific campaign to measure X-rays from kaonic-helium atoms.
  •  
2.
  • Hashimoto, T., et al. (författare)
  • Kaonic-Atom X-ray Spectroscopy with Superconducting Microcalorimeters
  • 2017
  • Ingår i: Proceedings of the 12th International Conference on Hypernuclear and Strange Particle Physics (HYP2015). - 9784890271221 ; 17
  • Konferensbidrag (refereegranskat)abstract
    • We will measure kaonic helium X-rays using transition-edge-sensor microcalorimeters, TES, in the J-PARC hadron experimental facility. To demonstrate the feasibility of the experiment, we performed a measurement of pionic carbon X-rays at PSI, where an excellent FWHM energy resolution of 7 eV at 6.4 keV was achieved. We also evaluated the expected TES performance in the kaon beam at J-PARC. The simulation results show that the TES spectrometer would work with a good energy resolution, and clear peaks of kaonic helium X-rays would be observed on a reasonably suppressed background.
  •  
3.
  • Okada, S., et al. (författare)
  • First application of superconducting transition-edge sensor microcalorimeters to hadronic atom X-ray spectroscopy
  • 2016
  • Ingår i: Progress of Theoretical and Experimental Physics. - : Oxford University Press (OUP). - 2050-3911. ; 2016:9
  • Tidskriftsartikel (refereegranskat)abstract
    • High-resolution pionic atom X-ray spectroscopy was performed with an X-ray spectrometer based on a 240 pixel array of superconducting transition-edge sensor (TES) microcalorimeters at the φM1 beam line of the Paul Scherrer Institute. X-rays emitted by pionic carbon via the 4f → 3d transition and the parallel 4d → 3p transition were observed with a full width at half maximum energy resolution of 6.8 eV at 6.4 keV. The measured X-ray energies are consistent with calculated electromagnetic values which considered the strong interaction effect assessed via the Seki-Masutani potential for the 3p energy level, and favor the electronic population of two filled 1s electrons in the K-shell. Absolute energy calibration with an uncertainty of 0.1 eV was demonstrated under a high-rate hadron beam condition of 1.45 MHz. This is the first application of a TES spectrometer to hadronic atom X-ray spectroscopy and is an important milestone towards next-generation high-resolution kaonic atom X-ray spectroscopy.
  •  
4.
  •  
5.
  • Doriese, W B, et al. (författare)
  • A practical superconducting-microcalorimeter X-ray spectrometer for beamline and laboratory science
  • 2017
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 88:5
  • Tidskriftsartikel (refereegranskat)abstract
    • We describe a series of microcalorimeter X-ray spectrometers designed for a broad suite of measurement applications. The chief advantage of this type of spectrometer is that it can be orders of magnitude more efficient at collecting X-rays than more traditional high-resolution spectrometers that rely on wavelength-dispersive techniques. This advantage is most useful in applications that are traditionally photon-starved and/or involve radiation-sensitive samples. Each energy-dispersive spectrometer is built around an array of several hundred transition-edge sensors (TESs). TESs are superconducting thin films that are biased into their superconducting-to-normal-metal transitions. The spectrometers share a common readout architecture and many design elements, such as a compact, 65 mK detector package, 8-column time-division-multiplexed superconducting quantum-interference device readout, and a liquid-cryogen-free cryogenic system that is a two-stage adiabatic-demagnetization refrigerator backed by a pulse-tube cryocooler. We have adapted this flexible architecture to mate to a variety of sample chambers and measurement systems that encompass a range of observing geometries. There are two different types of TES pixels employed. The first, designed for X-ray energies below 10 keV, has a best demonstrated energy resolution of 2.1 eV (full-width-at-half-maximum or FWHM) at 5.9 keV. The second, designed for X-ray energies below 2 keV, has a best demonstrated resolution of 1.0 eV (FWHM) at 500 eV. Our team has now deployed seven of these X-ray spectrometers to a variety of light sources, accelerator facilities, and laboratory-scale experiments; these seven spectrometers have already performed measurements related to their applications. Another five of these spectrometers will come online in the near future. We have applied our TES spectrometers to the following measurement applications: synchrotron-based absorption and emission spectroscopy and energy-resolved scattering; accelerator-based spectroscopy of hadronic atoms and particle-induced-emission spectroscopy; laboratory-based time-resolved absorption and emission spectroscopy with a tabletop, broadband source; and laboratory-based metrology of X-ray-emission lines. Here, we discuss the design, construction, and operation of our TES spectrometers and show first-light measurements from the various systems. Finally, because X-ray-TES technology continues to mature, we discuss improvements to array size, energy resolution, and counting speed that we anticipate in our next generation of TES-X-ray spectrometers and beyond.
  •  
6.
  • Uhlig, Jens, et al. (författare)
  • High-resolution X-ray emission spectroscopy with transition-edge sensors: present performance and future potential.
  • 2015
  • Ingår i: Journal of Synchrotron Radiation. - 1600-5775. ; 22:Pt 3, s. 766-775
  • Tidskriftsartikel (refereegranskat)abstract
    • X-ray emission spectroscopy (XES) is a powerful element-selective tool to analyze the oxidation states of atoms in complex compounds, determine their electronic configuration, and identify unknown compounds in challenging environments. Until now the low efficiency of wavelength-dispersive X-ray spectrometer technology has limited the use of XES, especially in combination with weaker laboratory X-ray sources. More efficient energy-dispersive detectors have either insufficient energy resolution because of the statistical limits described by Fano or too low counting rates to be of practical use. This paper updates an approach to high-resolution X-ray emission spectroscopy that uses a microcalorimeter detector array of superconducting transition-edge sensors (TESs). TES arrays are discussed and compared with conventional methods, and shown under which circumstances they are superior. It is also shown that a TES array can be integrated into a table-top time-resolved X-ray source and a soft X-ray synchrotron beamline to perform emission spectroscopy with good chemical sensitivity over a very wide range of energies.
  •  
7.
  • Uhlig, Jens, et al. (författare)
  • Table-Top Ultrafast X-Ray Microcalorimeter Spectrometry for Molecular Structure
  • 2013
  • Ingår i: Physical Review Letters. - 1079-7114. ; 110:13
  • Tidskriftsartikel (refereegranskat)abstract
    • This work presents an x-ray absorption measurement by use of ionizing radiation generated by a femtosecond pulsed laser source. The spectrometer was a microcalorimetric array whose pixels are capable of accurately measuring energies of individual radiation quanta. An isotropic continuum x-ray spectrum in the few-keV range was generated from a laser plasma source with a water-jet target. X rays were transmitted through a ferrocene powder sample to the detector, whose pixels have average photon energy resolution Delta E = 3.14 eV full-width-at-half-maximum at 5.9 keV. The bond distance of ferrocene was retrieved from this first hard-x-ray absorption fine-structure spectrum collected with an energy-dispersive detector. This technique will be broadly enabling for time-resolved observations of structural dynamics in photoactive systems. DOI: 10.1103/PhysRevLett.110.138302
  •  
8.
  • O’Neil, Galen C., et al. (författare)
  • Ultrafast Time-Resolved X-ray Absorption Spectroscopy of Ferrioxalate Photolysis with a Laser Plasma X-ray Source and Microcalorimeter Array
  • 2017
  • Ingår i: The Journal of Physical Chemistry Letters. - : American Chemical Society (ACS). - 1948-7185. ; 8:5, s. 1099-1104
  • Tidskriftsartikel (refereegranskat)abstract
    • The detailed pathways of photoactivity on ultrafast time scales are a topic of contemporary interest. Using a tabletop apparatus based on a laser plasma X-ray source and an array of cryogenic microcalorimeter X-ray detectors, we measured a transient X-ray absorption spectrum during the ferrioxalate photoreduction reaction. With these high-efficiency detectors, we observe the Fe K edge move to lower energies and the amplitude of the extended X-ray absorption fine structure reduce, consistent with a photoreduction mechanism in which electron transfer precedes disassociation. These results are compared to previously published transient X-ray absorption measurements on the same reaction and found to be consistent with the results from Ogi et al. and inconsistent with the results of Chen et al. (Ogi, Y.; et al. Struct. Dyn. 2015, 2, 034901; Chen, J.; Zhang, H.; Tomov, I. V.; Ding, X.; Rentzepis, P. M. Chem. Phys. Lett. 2007, 437, 50-55). We provide quantitative limits on the Fe-O bond length change. Finally, we review potential improvements to our measurement technique, highlighting the future potential of tabletop X-ray science using microcalorimeter sensors.
  •  
9.
  • Ullom, J N (creator_code:cre_t)
  • X-ray Spectrometer
  • 2019
  • Patent (övrigt vetenskapligt/konstnärligt)abstract
    • An x-ray spectrometer includes: an x-ray plasma source that produces first x-rays; an x-ray optic in optical communication with the x-ray plasma source and that: receives the first x-rays from the x-ray plasma source; focuses the first x-rays to produce second x-rays; and communicates the second x-rays to a sample that produces product x-rays in response to receipt of the second x-rays and second light; and a microcalorimeter array detector in optical communication with the sample and that receives the product x-rays from the sample.
  •  