  • Broman, L. M., et al. (författare)
  • Pressure and flow properties of dual-lumen cannulae for extracorporeal membrane oxygenation
  • 2020
  • Ingår i: Perfusion. - : SAGE Publications Ltd. - 0267-6591 .- 1477-111X.
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: In the last decade, dual-lumen cannulae have been increasingly applied in patients undergoing extracorporeal life support. Well-performing vascular access is crucial for efficient extracorporeal membrane oxygenation support; thus, guidance for proper cannulae size is required. Pressure–flow charts provided by manufacturers are often based on tests performed using water, rarely blood. However, blood is a shear-thinning and viscoelastic fluid characterized by different flow properties than water. Methods: We performed a study evaluating pressure–flow curves during standardized conditions using human whole blood in two commonly available dual-lumen cannulae used in neonates, pediatric, and adult patients. Results were merged and compared with the manufacturer’s corresponding curves obtained from the public domain. Results: The results showed that using blood as compared with water predominantly influenced drainage flow. A 10-80% higher pressure-drop was needed to obtain same drainage flow (hematocrit of 26%) compared with manufacturer’s water charts in 13-31 Fr bi-caval dual-lumen cannulae. The same net difference was found in cavo-atrial cannulae (16-32 Fr), where a lower drainage pressure was required (Hct of 26%) compared with the manufacturer’s test using blood with an Hct of 33%. Return pressure–flow data were similar, independent whether pumping blood or water, to the data reported by manufacturers. Conclusion: Non-standardized testing of pressure–flow properties of extracorporeal membrane oxygenation dual-lumen cannulae prevents an adequate prediction of pressure–flow results when these cannulae are used in patients. Properties of dual-lumen cannulae may vary between sizes within same cannula family, in particular concerning the drainage flow. 
  •  
3.
  • Di Nardo, M, et al. (författare)
  • A narrative review of the technical standards for extracorporeal life support devices (pumps and oxygenators) in Europe
  • 2018
  • Ingår i: Perfusion. - : SAGE Publications. - 1477-111X .- 0267-6591. ; 33:7, s. 553-561
  • Tidskriftsartikel (refereegranskat)abstract
    • This review summarizes the European rules to control the market when introducing new products. In particular, it shows all the steps to achieve the European Conformity (CE Mark), a certification that all new medical products must achieve before being used in Europe. Extracorporeal membrane oxygenation (ECMO) devices are exposed to the same procedures. Hereby, we present some regulatory issues regarding pumps and oxygenators, providing technical details as released by the manufacturers on their websites and information charts.
  •  
4.
  • Lepper, PM, et al. (författare)
  • Perception of prolonged extracorporeal membrane oxygenation in Europe: an EuroELSO survey
  • 2020
  • Ingår i: Perfusion. - : SAGE Publications. - 1477-111X .- 0267-6591. ; 35:1_suppl, s. 81-85
  • Tidskriftsartikel (refereegranskat)abstract
    • The substantial increase in the number of patients receiving extracorporeal membrane oxygenation over the last decade has led to an evolution of indications and an expansion into wider patient groups. One of the unanticipated benefits of the increase in extracorporeal membrane oxygenation has been a change in the understanding of the natural history of many respiratory diseases. Development in technology and materials, reduced extracorporeal membrane oxygenation–specific complications, and improvement of critical care, in general, have facilitated longer extracorporeal membrane oxygenation runs, and the definition of prolonged extracorporeal membrane oxygenation was recently expanded to continuous support for more than 28 days. This survey aimed to describe European ECMO centers’ perception and arbitrary definition of prolonged extracorporeal membrane oxygenation, patient management, and futility. Of 94 center responses, 37% regarded 14-21 days, 30% 21-28 days, and 28% >28 days as prolonged treatment. Bridge to recovery (64%) or to transplantation (20%) was the most common causes. Awake, and ambulation while on extracorporeal membrane oxygenation was reported from 34% of the centers. In case of perceived futility, decision to withdraw was taken in 65% of the centers in agreement between profession and family and in 30% by profession only. One-fourth of the centers did not discontinue support. Large differences prevail among European ECMO centers concerning local perception and patient management in prolonged extracorporeal membrane oxygenation.
  •  
5.
  •  
6.
  • Malfertheiner, MV, et al. (författare)
  • Ex vivo models for research in extracorporeal membrane oxygenation: a systematic review of the literature
  • 2020
  • Ingår i: Perfusion. - : SAGE Publications. - 1477-111X .- 0267-6591. ; 35:1_suppl, s. 38-49
  • Tidskriftsartikel (refereegranskat)abstract
    • With ongoing progress of components of extracorporeal membrane oxygenation including improvements of oxygenators, pumps, and coating materials, extracorporeal membrane oxygenation became increasingly accepted in the clinical practice. A suitable testing in an adequate setup is essential for the development of new technical aspects. Relevant tests can be conducted in ex vivo models specifically designed to test certain aspects. Different setups have been used in the past for specific research questions. We conducted a systematic literature review of ex vivo models of extracorporeal membrane oxygenation components. MEDLINE and Embase were searched between January 1996 and October 2017. The inclusion criteria were ex vivo models including features of extracorporeal membrane oxygenation technology. The exclusion criteria were clinical studies, abstracts, studies in which the model of extracorporeal membrane oxygenation has been reported previously, and studies not reporting on extracorporeal membrane oxygenation components. A total of 50 studies reporting on different ex vivo extracorporeal membrane oxygenation models have been identified from the literature search. Models have been grouped according to the specific research question they were designed to test for. The groups are focused on oxygenator performance, pump performance, hemostasis, and pharmacokinetics. Pre-clinical testing including use of ex vivo models is an important step in the development and improvement of extracorporeal membrane oxygenation components and materials. Furthermore, ex vivo models offer valuable insights for clinicians to better understand the consequences of choice of components, setup, and management of an extracorporeal membrane oxygenation circuit in any given condition. There is a need to standardize the reporting of pre-clinical studies in this area and to develop best practice in their design.
  •  