SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Tägil Magnus professor) "

Sökning: WFRF:(Tägil Magnus professor)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Lundqvist, Eva, 1985- (författare)
  • Distal radius fractures AO type C : A clinical and radiographic investigation
  • 2022
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • The function of the hand is of substantial importance, and injuries have an impact on daily life. Distal radius fracture (DRF) is the most common fracture among adults. The annual incidence is 26 per 10,000 inhabitants, and the incidence is increasing because of an aging population. There has been a shift from conservative and other operative treatments, toward volar plate fixation to restore the anatomy and improve results. Operative treatment is often considered for displaced and unstable fractures. The optimal choice of treatment and fixation is still debated. The aim of this thesis was to study results after internal fixation of DRF AO type C.Study I (retrospective study, n=74) assessed outcomes after combined plating (CP) of DRFs AO type C, with 1-year follow-up. CP restored the anatomy and achieved a good functional outcome. The radiographic outcome did not correspond to the clinical or functional outcome.Study II (prospective study, n=97) assessed the prevalence of post-traumatic arthritis (PA) following CP of DRFs AO type C. CP yielded a good clinical outcome 7 years postoperatively and the prevalence of PA was low (29%). The presence of PA did not correlate with fracture group, radio-graphic, clinical, or functional outcome. Study III (randomized controlled trial, n=147) assessed the radiographic and clinical outcome following surgical treatment of DRFs AO type C, comparing volar plating (VP) with CP. Fixation with VP yieldedthe same radiographic and functional results as CP, but with a lower frequency of complications in the VP group.Study IV (prospective pilot study, n=10) assessed fragment migration with CTMA (CT-based micromotion analysis) after osteosynthesis with VP after DRF AO type C. The CTMA technique indicated that variable angle volar locking plate fixation can yield and maintain a stable reduction of the fracture fragments. CT volume registration could be a valuable tool in the detailed assessment of fracture fragment migration following VP fixation of DRFs. 
  •  
2.
  • Scheer, Johan, 1967- (författare)
  • Periulnar Injuries Associated with Distal Radius Fractures
  • 2011
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Residual dysfunction after a fracture of the distal radius is most often mild but may give rise to significant impairment especially in the younger active population. The symptoms often manifest around the distal ulna when loading the hand or rotating the forearm. In this region are found articular and soft tissue connections running from the distal ulna to the distal radius as well as to the ulnar side of the carpus. The aims of this thesis were to investigate the effects of distal radius fractures on the structures about the distal ulna and to what extent malunion and ulnar soft tissue lesions affect function. Both patients and cadaver specimens were used in the five different studies.In a retrospective study of 17 malunited distal radius fractures supination impairment improved significantly by correction of the skeletal malunion. This highlights the importance of distal radioulnar joint congruity for forearm rotation in a subset of cases.The pathomechanisms of injury to the triangular fibrocartilage complex (TFCC) were studied. In a cadaveric distal radius fracture model different restraining properties and injury patterns were investigated. Similar patterns of injury were then observed in 20 patients with a displaced distal radius fracture. It was found that a TFCC injury can be expected with dorsal displacement of the distal radius fragment of 32o or more from the anatomically correct position. The distribution of a TFCC injury apparently differs depending on the size of an associated ulnar styloid fracture. In cases of an intact ulnar styloid or a concomitant tip fracture (Type 1) the first stage of injury seems to be extensor carpi ulnaris subsheath separation from the distal ulna and the dorsal radioulnar ligament. Thereafter follows a disruption of the deep insertions into the fovea of the ulna starting from the palmar and extending dorsally and radially. An extensive injury can be detected with a novel non-invasive test called the ‘bald ulnar head test’, which is performed under anaesthesia.Diagnosis of an acute TFCC injury is difficult using non-invasive methods. In a prospective study of 48 patients, CT scanning to detect pathologic subluxation was found to be of little use in both acute and chronic cases, and is therefore not endorsed on this indication. A radioulnar stress test, which in previous studies has correlated well to a deep TFCC injury, was found to be highly reliable but not to correspond with significant disability in self-administered questionnaires of functional outcome two years or more after injury. This indicates that the subset of patients possibly benefiting from acute repair must be identified by other means.
  •  
3.
  • Wadsten, Mats, 1969- (författare)
  • Distal Radius Fractures : aspects on radiological and clinical outcome and evaluation of a new classification system
  • 2016
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Distal radius fracture (DRF) is the most common fracture encountered in clinical practice. Every year, more than 20000 people in Sweden suffer from this injury. It has been shown that there is a correlation between malalignment and function following distal radial fractures and malunion may cause persistent pain and disability.A problem has been in making a correct initial assessment of the fracture. Many fractures are unstable despite an acceptable position on the initial radiographic examination or following a successful closed fracture reduction.Numerous classification systems have been developed for evaluation of DRF in order to predict the outcome. However, the values of these are limited since they have not shown satisfactory reliability. Furthermore, the utility of these systems to predict radiographic or clinical outcome is not yet proven. These shortcomings may be one reason why optimal DRF management is still controversial. Requests for a new classification system of DRF, predictive of outcome and easy to use, have been made.Improvement in initial assessment of DRF will benefit a large group of patients, as well as the society, by reducing persistent symptoms and disability.Study I: In this study we evaluated the interobserver and intraobserver reliability of a new classification system (the Buttazzoni classification). Two hundred and thirty-two patients with acute DRF were blindly evaluated using the new classification by three orthopaedic surgeons twice with a 1-year interval. The new classification showed fair to substantial interobserver and intraobserver reliability, i.e., results comparable with other commonly used classification systems.Study II: This was a prospective multicenter study of fracture stability in 428 DRF. The study investigated whether cortical comminution and intra-articular involvement, as well as the new classification system, could predict displacement in DRF. Logistic regression analysis showed that initial position of the fracture and volar or dorsal comminution predicted later displacement, while intra-articular involvement did not. Volar comminution was the strongest predictor of displacement. The new classification system, which is the first to include volar comminution as a separate parameter, was highly predictive of fracture instability. Furthermore we found that it is quite common for non-operatively treated fractures to displace at a later stage than two weeks.Study IV: In study II it was found that late displacement of DRF, still in acceptable radiologic position after 10-14 days, occurred in approximately 1/3 of cases. Despite this, we have not been able to find any study focusing on evaluating the clinical outcome in patients with late displacement. Two hundred and nine unilateral DRF from study II were still in good position after 10-14 days and were included in the study. One hundred and seventy five patients had radiographs taken at a minimum of 3 months and a clinical examination 1 year after the fracture. Late displaced distal radius fractures had significantly higher loss of ROM and grip strength compared to fractures that didn’t displace. No significant differences were seen in subjective outcome.In conclusion, initial position of the fracture predicted later displacement and was the most important parameter in predicting clinical outcome. Comminution of the fracture also affected radiological stability and clinical outcome. Volar comminuted fractures are highly unstable and need surgical intervention if displacement is to be avoided. Intra-articular involvement affected clinical outcome. Late displacement is common in DRF and may result in loss of range of motion and grip strength. To detect late displacement, DRF should be followed for more than 2 weeks.The new classification system had a moderate reliability and reproducibility. The classification was found predictive of radiologic and objective clinical outcome. However, it was not predictive of subjective outcome. The classification system was also predictive of fractures at risk for late displacement.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy