1.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  • Rodriguez-Palmero, Agusti, et al. (författare)
  • DLG4-related synaptopathy : a new rare brain disorder
  • 2021
  • Ingår i: Genetics in Medicine. - : Elsevier BV. - 1098-3600 .- 1530-0366. ; 23:5, s. 888-899
  • Tidskriftsartikel (refereegranskat)abstract
    • PurposePostsynaptic density protein-95 (PSD-95), encoded by DLG4, regulates excitatory synaptic function in the brain. Here we present the clinical and genetic features of 53 patients (42 previously unpublished) with DLG4 variants.MethodsThe clinical and genetic information were collected through GeneMatcher collaboration. All the individuals were investigated by local clinicians and the gene variants were identified by clinical exome/genome sequencing.ResultsThe clinical picture was predominated by early onset global developmental delay, intellectual disability, autism spectrum disorder, and attention deficit–hyperactivity disorder, all of which point to a brain disorder. Marfanoid habitus, which was previously suggested to be a characteristic feature of DLG4-related phenotypes, was found in only nine individuals and despite some overlapping features, a distinct facial dysmorphism could not be established. Of the 45 different DLG4 variants, 39 were predicted to lead to loss of protein function and the majority occurred de novo (four with unknown origin). The six missense variants identified were suggested to lead to structural or functional changes by protein modeling studies.ConclusionThe present study shows that clinical manifestations associated with DLG4 overlap with those found in other neurodevelopmental disorders of synaptic dysfunction; thus, we designate this group of disorders as DLG4-related synaptopathy.
  •  
6.
  •  
7.
  • Lage, Kasper, et al. (författare)
  • A human phenome-interactome network of protein complexes implicated in genetic disorders
  • 2007
  • Ingår i: Nature Biotechnology. - : Springer Science and Business Media LLC. - 1546-1696 .- 1087-0156. ; 25:3, s. 309-316
  • Tidskriftsartikel (refereegranskat)abstract
    • We performed a systematic, large-scale analysis of human protein complexes comprising gene products implicated in many different categories of human disease to create a phenome-interactome network. This was done by integrating quality-controlled interactions of human proteins with a validated, computationally derived phenotype similarity score, permitting identification of previously unknown complexes likely to be associated with disease. Using a phenomic ranking of protein complexes linked to human disease, we developed a Bayesian predictor that in 298 of 669 linkage intervals correctly ranks the known disease-causing protein as the top candidate, and in 870 intervals with no identified disease-causing gene, provides novel candidates implicated in disorders such as retinitis pigmentosa, epithelial ovarian cancer, inflammatory bowel disease, amyotrophic lateral sclerosis, Alzheimer disease, type 2 diabetes and coronary heart disease. Our publicly available draft of protein complexes associated with pathology comprises 506 complexes, which reveal functional relationships between disease-promoting genes that will inform future experimentation.
  •  
8.
  •  
9.
  • Erturk, Gizem, et al. (författare)
  • Microcontact imprinting based surface plasmon resonance (SPR) biosensor for real-time and ultrasensitive detection of prostate specific antigen (PSA) from clinical samples
  • 2016
  • Ingår i: Sensors and Actuators B: Chemical. - : Elsevier BV. - 0925-4005. ; 224, s. 823-832
  • Tidskriftsartikel (refereegranskat)abstract
    • Prostate specific antigen (PSA) is an important biomarker for diagnosis and prognosis of prostate cancer. Herein, microcontact PSA-imprinted surface plasmon resonance (SPR) sensor chip was developed for sensitive, real-time detection of PSA. The imprinted chip was prepared in the presence of methacrylic acid (MAA) as functional monomer and ethylene glycol dimethacrylate (EGDMA) as cross-linker via UV polymerization using microcontact imprinting technique. PSA imprinted SPR sensor chip was characterized by atomic force microscope (AFM), scanning electron microscope (SEM), ellipsometry, dispersive Raman and Fourier transform infrared spectroscopy (FT-IR). Under optimal conditions, PSA detection was performed with standard PSA solutions in the concentration range of 0.1-50 ng mL(-1) with a detection limit (LOD) of approximately 91 pg mL(-1) (18 x 10(-14) M). Selectivity studies were performed against human serum albumin (HSA) and lysozyme (Lyz) as the competitive agents. The developed system was evaluated for analysis of 10 clinical serum samples and showed approximately 98% agreement between the results obtained by commercial enzyme-linked immunosorbent assay (ELISA) method without significant differences at the 0.05 significance level (p = 0.751, p >0.05). (C) 2015 Elsevier B.V. All rights reserved.
  •  
10.
  • Erturk, Gizem, et al. (författare)
  • Real-time prostate-specific antigen detection with prostate-specific antigen imprinted capacitive biosensors
  • 2015
  • Ingår i: Analytica Chimica Acta. - : Elsevier BV. - 1873-4324 .- 0003-2670. ; 891, s. 120-129
  • Tidskriftsartikel (refereegranskat)abstract
    • Prostate specific antigen (PSA) is a valuable biomarker for early detection of prostate cancer, the third most common cancer in men. Ultrasensitive detection of PSA is crucial to screen the prostate cancer in an early stage and to detect the recurrence of the disease after treatment. In this report, microcontact-PSA imprinted (PSA-MIP) capacitive biosensor chip was developed for real-time, highly sensitive and selective detection of PSA. PSA-MIP electrodes were prepared in the presence of methacrylic acid (MAA) as the functional monomer and ethylene glycol dimethacrylate (EGDMA) as the cross-linker via UV polymerization. Immobilized Anti-PSA antibodies on electrodes (Anti-PSA) for capacitance measurements were also prepared to compare the detection performances of both methods. The electrodes were characterized by atomic force microscopy (AFM), scanning electron microscopy (SEM) and cyclic voltammetry (CV) and real-time PSA detection was performed with standard PSA solutions in the concentration range of 10 fg mL(-1) -100 ng mL(-1). The detection limits were found as 8.0 x 10(-5) ng mL(-1) (16 x 10(-17) M) and 6.0 x 10(-4) ng mL(-1) (12 x 10(-16) M) for PSA-MIP and Anti-PSA electrodes, respectively. Selectivity studies were performed against HSA and IgG and selectivity coefficients were calculated. PSA detection was also carried out from diluted human serum samples and finally, reproducibility of the electrodes was tested. The results are promising and show that when the sensitivity of the capacitive system is combined with the selectivity and reproducibility of the microcontact-imprinting procedure, the resulting system might be used successfully for real-time detection of various analytes even in very low concentrations. (C) 2015 Elsevier B.V. All rights reserved.
  •  