SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Tamburino Corrado) "

Sökning: WFRF:(Tamburino Corrado)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Cannata, Stefano, et al. (författare)
  • One-year outcomes after transcatheter aortic valve implantation with the latest-generation SAPIEN balloonexpandable valve : the S3U registry
  • 2023
  • Ingår i: EuroIntervention. - : Europa Digital & Publishing. - 1774-024X .- 1969-6213. ; 18:17, s. 1418-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Initial data about the performance of the new-generation SAPIEN 3 Ultra (S3U) valve are highly promising. However, evidence about the longer-term performance and safety of the S3U is scarce.Aims: We aimed to investigate the 1-year clinical and echocardiographic outcomes of transcatheter aortic valve implantation (TAVI) using the S3U compared with its predecessor, the SAPIEN 3 valve (S3).Methods: The SAPIEN 3 Ultra registry included consecutive patients who underwent transfemoral TAVI at 12 European centres with the S3U or S3 between October 2016 and December 2020. One-to-one propensity score (PS) matching was performed to account for differences in baseline characteristics. The primary outcomes of interest were all-cause death and the composite of all-cause death, disabling stroke and hospitalisation for heart failure at 1 year.Results: The overall study cohort encompassed 1,692 patients treated with either the S3U (n=519) or S3 (n=1,173). The PS-matched population had a total of 992 patients (496 per group). At 1 year, the rate of death from any cause was 4.9% in the S3U group and 6.3% in the S3 group (p=0.743). Similarly, there were no significant differences in the rates of the primary composite outcome (9.5% in the S3 group and 6.6% in the S3U group; p=0.162). The S3U was associated with lower rates of mild paravalvular leak (PVL) compared with the S3 (odds ratio 0.63, 95% confidence interval: 0.44 to 0.88; p<0.01). No significant differences in transprosthetic gradients were observed between the two groups.Conclusions: Compared with the S3, the S3U transcatheter heart valve was associated with similar 1-year clinical outcomes but reduced rates of mild PVL.
  •  
2.
  • Hansson, Nicolaj C., et al. (författare)
  • The impact of calcium volume and distribution in aortic root injury related to balloon-expandable transcatheter aortic valve replacement
  • 2015
  • Ingår i: JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY. - : ELSEVIER SCIENCE INC. - 1934-5925. ; 9:5, s. 382-392
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: A detailed assessment of calcium within the aortic root may provide important additional information regarding the risk of aortic root injury during transcatheter heart valve replacement (TAVR). Objective: We sought to delineate the effect of calcium volume and distribution on aortic root injury during TAVR. Methods: Thirty-three patients experiencing aortic root injury during TAVR with a balloon-expandable valve were compared with a control group of 153 consecutive TAVR patients without aortic root injury (as assessed by post-TAVR multidetector CT). Using commercial software to analyze contrast-enhanced pre-TAVR CT scans, caltium volume was determined in 3 regions: (1) the overall left ventricular outflow tract (LVOT), extending 10 mm down from the aortic annulus plane; (2) the upper LVOT, extending 2 mm down from the annulus plane; and (3) the aortic valve region. Results: Calcium volumes in the upper LVOT (median, 29 vs 0 mm(3); P less than .0001) and overall LVOT (median, 74 vs 3 mm(3); P = .0001) were higher in patients who experienced aortic root injury compared with the control group. Calcium in the aortic valve region did not differ between groups. Upper LVOT calcium volume was more predictive of aortic root injury than overall LVOT calcium volume (area under receiver operating curve [AUG]; 0.78; 95% confidence interval, 0.69-0.86 vs AUC, 0.71; 95% confidence interval, 0.62-0.82; P = .010). Upper LVOT calcium below the noncoronary cusp was significantly more predictive of aortic root injury compared to calcium underneath the right coronary cusp or the left coronary cusp (AUC, 0.81 vs 0.68 vs 0.64). Prosthesis oversizing greater than20% (likelihood ratio test, P = .028) and redilatation (likelihood ratio test, P = .015) improved prediction of aortic root injury by upper LVOT calcium volume. Conclusion: Calcification of the LVOT, especially in the upper LVOT, located below the noncoronary cusp and extending from the annular region, is predictive of aortic root injury during TAVR with a balloon-expandable valve. (C) 2015 Society of Cardiovascular Computed Tomography. All rights reserved.
  •  
3.
  • Kim, Won Keun, et al. (författare)
  • Outcomes and performance of the ACURATE neo2 transcatheter heart valve in clinical practice : one-yearresults of the ACURATE neo2 PMCF Study
  • 2024
  • Ingår i: EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. - 1969-6213. ; 20:1, s. 85-94
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Transcatheter aortic valve implantation is an effective treatment for patients with aortic stenosis; however, complications related to paravalvular leakage (PVL) persist, including increased risk of mortality, cardiovascular mortality, and rehospitalisation. AIMS: We sought to evaluate the clinical outcomes and valve performance at 1 year in patients with severe aortic stenosis treated with the ACURATE neo2 valve in a post-market clinical setting. METHODS: Valve Academic Research Consortium-2 safety events were assessed up to 1 year. Independent core laboratories evaluated echocardiographic measures of valve performance and hypoattenuated leaflet thickening (HALT; as measured by four-dimensional computed tomography). RESULTS: The study enrolled 250 patients (64% female; mean age: 81 years; baseline Society of Thoracic Surgeons risk score: 2.9±2.0%); 246 patients were implanted with ACURATE neo2. All-cause mortality was 0.8% at 30 days and 5.1% at 1 year. The 1-year rates for stroke and disabling stroke were 3.0% and 1.3%, respectively. Overall, HALT of >50% leaflet involvement of at least one leaflet was present in 9% of patients at 30 days and in 12% of patients at 1 year. No association was observed between the presence of HALT and 1-year clinical or haemodynamic outcomes. Early haemodynamic improvements were maintained up to 1 year (mean aortic valve gradient: 47.6±14.5 mmHg at baseline, 7.6±3.2 mmHg at 1 year; mean aortic valve area: 0.7±0.2 cm2 at baseline, 1.7±0.4 cm2 at 1 year). At 1 year, 99% of patients had mild or no/trace PVL (<1% had moderate PVL; no patient had severe PVL). CONCLUSIONS: The study outcomes confirm favourable performance and safety up to 1 year in patients treated with ACURATE neo2 in routine clinical practice. (ClinicalTrials.gov: NCT04655248).
  •  
4.
  • Zimarino, Marco, et al. (författare)
  • Left ventricular size predicts clinical benefit after percutaneous mitral valve repair for secondary mitral regurgitation : A systematic review and meta-regression analysis
  • 2020
  • Ingår i: Cardiovascular Revascularization Medicine. - : Elsevier BV. - 1553-8389. ; 21:7, s. 857-864
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The benefit of percutaneous mitral valve repair (PMVR) in patients with secondary MR is still debated. We aimed to compare the outcome of PMVR with optimal medical therapy (OMT) versus OMT alone in patients with secondary mitral regurgitation (MR) and to assess the role of potential effect modifiers. Methods: We performed a systematic review and meta-analysis of 2 randomized clinical trials (RCT) and 7 non-randomized observational studies (nROS). Hazard ratios (HR) and 95% confidence intervals (CI) were pooled through inverse variance random-effects model to compute the summary effect size for all-cause death, cardiovascular death and cardiac-related hospitalization. Subgroup and meta-regression analysis were also performed. Results: An overall population of 3118 individuals (67% men; mean age, 73 years) was included: 1775 PMVR+OMT and 1343 OMT patients, with mean follow-up of 24 ± 15 months. PMVR+OMT was associated with a lower risk of all-cause death (HR: 0.77; 95% CI: 0.68–0.87), cardiovascular death (HR: 0.55; 95% CI: 0.34–0.89) and cardiac-related hospitalization (HR:0.77; 95% CI: 0.64–0.92). Meta-regression analysis showed that larger left ventricular end-diastolic volume index (LVEDVI) portends higher risk of all-cause death, cardiovascular death and cardiac-related hospitalization after PMVR (p < 0.001 for all). Conclusions: This study-level meta-analysis shows that PMVR+OMT is associated with reduced all-cause death, cardiovascular death and cardiac-related hospitalization when compared with OMT alone in secondary MR. LVEDVI is a predictive marker of efficacy, as patients with smaller LVEDVI have been shown to derive the largest benefit from PMVR.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy