SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Tammo Kristian) "

Sökning: WFRF:(Tammo Kristian)

  • Resultat 1-10 av 15
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Blanksvärd, Thomas, et al. (författare)
  • Textile reinforced concrete sandwich panels
  • 2011
  • Ingår i: Nordic Concrete Research. - Oslo : Norsk Betongforening. - 9788282080255 ; , s. 517-520
  • Konferensbidrag (refereegranskat)
  •  
2.
  •  
3.
  • Flansbjer, Mathias, et al. (författare)
  • Textile reinforced concrete sandwich panels
  • 2012
  • Ingår i: fib Symposium 2012: Concrete Structures for Sustainable Community - Proceedings. - Stockholm : Swedish Conrete Association. - 9789198009811 ; , s. 169-172
  • Konferensbidrag (refereegranskat)abstract
    • The main reason for the thickness of a concrete sandwich element is the requirement for the protective concrete cover for the steel reinforcement. By changing the steel reinforcement to non-corrosive textile fibre net this requirement could be strongly reduced. Use of textile reinforced concrete (TRC) makes it possible to produce much thinner and slimmer concrete facades in the future without changing their mechanical properties. This article presents selected results from Tekocrete project (Formas-BIC) concerning pilot production, modelling and full-scale testing of new light weight sandwich elements reinforced with AR glass and carbon fibre nets.
  •  
4.
  • Hagberg, Cecilia, et al. (författare)
  • Projektrapport om läckage från gödselbehållare av betong : inspektion och egenkontroll
  • 2019
  • Rapport (övrigt vetenskapligt/konstnärligt)abstract
    • Behållare för lagring av gödsel bör kontrolleras i samband med tömning. I författningar står att en verksamhetsutövare har ansvar att skydda både miljö och människor från skada och olägenheter. En sådan skada skulle kunna vara en läckande gödselbehållare som bl.a. kan förorena vatten i omgivningen. Förutom verksamhetsutövarens ansvar står i författningar att lagringsutrymmen för gödsel ska vara utformade så att avrinning och läckage till omgivningen inte sker. Det är generellt svårt att bygga och uppföra en lagringsbehållare så den är absolut tät. Skarvar mellan betongelement och rörgenomförningar är partier som är känsliga för läckage. I media uppmärksammas ibland att gödselbehållare läckt eller havererat. Den faktiska förekomsten och omfattningen av läckage från lagringsutrymmen för stallgödsel är okänd.I detta projekt har en sakkunnig på betong varit ute på gårdar och inspekterat gödselbrunnar för att dokumentera vanliga skador på behållare samt få en överblick över skadeorsaker och föreslå reparationsmetoder. Den sakkunniga har även utfört täckskiktsmätning på flera behållare samt provat georadar på enstaka behållare för att prova dessa undersökningsmetoder vid kontroll av gödselbehållare. Utifrån de inspekterade gödselbrunnarna går det inte att avgöra hur vanligt förekommande skador på gödselbehållare är eller hur omfattande eventuella läckage är. Dock har de praktiska delarna kompletterats med litteraturgenomgång och sammanställts i denna rapport för att bl.a. fungera som ett hjälpmedel för en verksamhetsutövare som ska utföra egenkontroll av en gödselbehållare.Skador på gödselbehållare uppkommer genom mekanisk eller kemisk påverkan. Denvanligaste mekaniska skadan är påkörning som kan resultera i skador av ringa eller större omfattning. Kemisk påverkan kan vara rostangrepp på armering eller vajrar samt syraangrepp på betongen. Skadorna kan ha olika utseende från små sprickor till grova brott. En allvarlig skada på en gödselbrunn är om vajrar är skadade. Rörgenomförningar genom behållarvägg är ofta partier som är extra utsatta för skador.Genom att kontrollera brunnen kontinuerligt kan förändringar i behållarkonstruktionen upptäckas. Det är alltid bra att ta bild av skador man upptäckt eftersom dessa kan fungera som underlag vid konsultation med en sakkunnig om till exempel skadans art och erforderlig reparationsmetod. Lagning av gödselbehållare bör alltid ske med en metod som föreslås av en sakkunnig. Sakkunniga är bl.a. konstruktörer och betongexperter samt finns även hos tillverkare av gödselbehållare.Det är även viktigt att förebygga skador på behållare. En av de viktigaste faktorerna för att förbygga skador på gödselbehållaren är att följa tillverkarens anvisningar för hur behållaren ska användas och vilka försiktighetsåtgärder man måste vidta i bruksskedet. Vid anlitande av till exempel maskinstationer för gödselspridning är det viktigt att även dessa får information som berör dem i deras arbete. Till exempel vilket minsta avstånd de måste hålla till en gödselbrunn. Andra sätt att förebygga skador är att ta bort vegetation i form av buskar och träd som vuxit upp runt behållaren. En rekommendation är att hålla fritt, från kraftigare vegetation eller materialupplag, minst sex meter kring behållaren.I Danmark finns ett uppbyggt kontrollsystem för gödselbehållare där certifierade kontrollanter besiktigar behållare. Detta danska kontrollsystem beskrivs till viss del i denna rapport. Dessutom beskrivs den svenska miljö- och arbetsmiljölagstiftningen som reglerar verksamhetsutövarens ansvar utifrån olika aspekter.Ambitionen med denna rapport är att underlätta för verksamhetsutövare att utföra egenkontroll av gödselbehållare. Rapporten omfattar inte konstruktionsbeskrivningar eller mer omfattande utredningar av behållarkonstruktionen. Inte heller uppförande av nya gödselbehållare beskrivs.
  •  
5.
  • Malaga, Katarina, et al. (författare)
  • Alkali Resistance of Textile Reinforcement for Concrete Façade Panels
  • 2014
  • Ingår i: XXII NORDIC CONCRETE RESEARCH SYMPOSIUM.
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • Textile reinforced concrete has been proven to be a suitable solution for the production of thin and lightweight façade panels. Despite it being researched over the past decade, its long-term durability is not sufficiently characterized. This article presents experimental results from accelerated aging and direct tensile testing of various textile reinforcement alternatives according to ISO 10406-1. Based on the results, a large degeneration of the glass and basalt fibre bars was observed after 30 days of immersion. As for carbon fibre grids, no significant difference in ultimate tensile force was noted before and after immersion.
  •  
6.
  •  
7.
  • Tammo, Kristian (författare)
  • A NEW APPROACH TO CRACK CONTROL FOR REINFORCED CONCRETE - An investigation of crack widhts close to the reinforcement and the correlation to service life
  • 2009
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • One of the most important factors governing durability of concrete structures is reinforcement corrosion, and to prevent degradation associated with it, it is desirable to use large concrete covers. However, if the concrete cover is increased, the majority of design methods will predict that the crack widths at the concrete surface increase significantly. This can be contradictory, since the same design methods both specify smallest concrete cover and require crack width limitations to prevent reinforcement corrosion. To fulfil crack control demands current European structural codes imply that the engineer tend to use as small covers as possible, use small diameter reinforcement bars with narrow spacing and place excessive amounts of crack reinforcement in sections with high bending moments. All these measures are disadvantageous with respect to durability, which is best achieved by increasing the concrete cover and providing space for effective casting of the concrete. The structural codes focus on limitation of crack widths at the concrete surface, which is well defined and measurable. However, in view of durability the crack width close to the bars should be more decisive for the durability and service life of the structure. The width of the cracks close to the bar can be expected to control the total amount of free oxygen, moisture and other corrosive agents transported via the crack to the reinforcement. This thesis examines the crack width close to the bar surface and the correlation to parameters such as steel stress, concrete cover, steel diameter and concrete quality. The test results show that the crack widths on the concrete surface are of the order twice the crack width close to the bar surface and that the crack width near the reinforcement bar is much less affected by a change in concrete cover than the crack width at the concrete surface. The test results also showed that the crack width close to the bar is affected only to a limited extent by bar diameter and concrete quality and that steel stress is the dominating parameter. During the tests it was noticed that small inclined cracks developed at the bar interface and in the vicinity of the crack so that the concrete near the bar was separated from the rest of the concrete and more or less followed the bar. This mechanism has similarities with pull-out failures, but is limited by the continuous reinforcement. The formation of the small inclined cracks induced a cone shaped concrete piece, which is the main reason for the different development of crack widths close to the reinforcement and at the concrete surface. Non-linear FE-calculations have also been performed, showing similar relations between the crack width close to the reinforcement bar and the crack width at the concrete surface, as the experimental tests described above. The FE-analysis confirmed that the crack width close to the reinforcement bar was almost unaffected by the thickness of the concrete cover. In the results from the FE-calculations the formation of the cone shaped concrete piece during the tensile loading was described in more detail. vi To evaluate the total effect of crack widths and concrete cover on the corrosion risk, cracked beams exposed to chlorides have also been tested. The main conclusion from this test series was that large concrete covers protect the reinforcement better than small concrete covers from chloride induced corrosion for exposure from below, even if the crack widths are larger at the concrete surface. It was also shown that the corrosion risk increases for chloride exposure from above and for high steel stresses.
  •  
8.
  • Tammo, Kristian, et al. (författare)
  • Crack Behavior near Reinforcing Bars in Concrete Structures
  • 2009
  • Ingår i: ACI Structural Journal. - 0889-3241. ; 106:3, s. 259-267
  • Tidskriftsartikel (refereegranskat)abstract
    • Currently used design methods predict that the crack widths at the concrete surface will increase significantly with concrete cover Requirements concerning limitation of crack widths therefore make it difficult to use large concrete covers, which are otherwise desirable to reduce the reinforcement corrosion. For this reason, it would be more relevant to use the crack width in the vicinity of the reinforcing bars as an indicator. In this paper an experimental study to investigate how different parameters affect the crack width at the reinforcement level is presented. Axially loaded concrete prisms with central reinforcing bars were tested with a method that makes it possible to indirectly investigate crack widths near the reinforcement. Concrete cover bar diameter and concrete quality were varied. The test results show that the crack width close to the bar is affected only to a limited extent by concrete cover, bar diameter and concrete quality, as well as by the fact that steel stress is the dominating parameter.
  •  
9.
  • Tammo, Kristian, et al. (författare)
  • Crack Widths Close to the Reinforcement
  • 2007
  • Ingår i: IABSE Symposium Improving Infrastructure Worldwide.
  • Konferensbidrag (refereegranskat)abstract
    • Currently used design methods predict that the crack widths at the concrete surface increase significantly with concrete cover. Requirements concerning limitation of crack widths therefore makes it difficult to use large concrete covers, which otherwise is desirable to reduce the corrosion of reinforcement. For this reason it would be more relevant to limit the crack width in the vicinity of the reinforcement bars. In this paper experimental studies to investigate how concrete cover affects the crack width at the reinforcement level are presented. Axially loaded concrete prisms with central reinforcement bars and beams loaded with bending moment are tested with a method making it possible to measure crack widths near the reinforcement. Concrete cover, bar diameter and concrete quality are varied. The test results show that the crack width close to the bar is only to a limited extent affected by concrete cover, bar diameter and concrete quality. Three-dimensional, non-linear FE-calculations are also performed to understand the mechanisms determining the properties of a crack.
  •  
10.
  • Tammo, Kristian, et al. (författare)
  • Crack widths near reinforcement bars for beams in bending
  • 2009
  • Ingår i: Structural Concrete. - : Thomas Telford Ltd.. - 1751-7648 .- 1464-4177. ; 10:1, s. 27-34
  • Tidskriftsartikel (refereegranskat)abstract
    • Earlier research performed on axially loaded concrete prisms shows that crack widths close to reinforcement are smaller and less dependent on concrete cover than crack widths at the concrete surface. To check practical applicability of these results a similar experimental investigation of cracking behaviour has been undertaken for beams loaded in bending. The influence of steel stress and concrete cover on crack widths close to the reinforcement and at the concrete surface has been investigated. The results show that the main features of cracking behaviour for axially loaded prisms and beams are similar. Beams resemble axially loaded prisms in that cone-shaped concrete failure occurs in the bond zone where the bar meets a crack. At higher steel stresses this concrete cone follows the displacement. For this reason crack widths close to the bar are significantly smaller and much less affected by the thickness of concrete cover than at the concrete surface. Surface crack widths consequently are poor indicators of the potential for exposure to corrosive attacks on reinforcement and current design methods can be counter-productive for service life of concrete structures. [doi: 10.1680/stco.2009.10.1.27]
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 15

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy