SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Tangl S.) "

Sökning: WFRF:(Tangl S.)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Porro, M., et al. (författare)
  • The MiniSDD-Based 1-Mpixel Camera of the DSSC Project for the European XFEL
  • 2021
  • Ingår i: IEEE Transactions on Nuclear Science. - : Institute of Electrical and Electronics Engineers Inc.. - 0018-9499 .- 1558-1578. ; 68:6, s. 1334-1350
  • Tidskriftsartikel (refereegranskat)abstract
    • The first DSSC 1-Mpixel camera became available at the European XFEL (EuXFEL) in the Hamburg area in February 2019. It was successfully tested, installed, and commissioned at the Spectroscopy and Coherent Scattering Instrument. DSSC is a high-speed, large-area, 2-D imaging detector system optimized for photon science applications in the energy range between 0.25 and 6 keV. The camera is based on direct conversion Si sensors and is composed of 1024 × 1024 pixels of hexagonal shape with a side length of 136∼μm. The 256 application-specific integrated circuits (ASICs) provide full parallel readout, comprising analog filtering, digitization, and in-pixel data storage. In order to cope with the demanding X-ray pulse time structure of the EuXFEL, the DSSC provides a peak frame rate of 4.5 MHz. The first Mpixel camera is equipped with miniaturized silicon drift detector (MiniSDD) pixel arrays. The intrinsic response of the pixels and the linear readout limit the dynamic range but allow one to achieve noise values of about 60 electrons r.m.s. at the highest frame rate. The challenge of providing high-dynamic range (104 photons/pixel/pulse) and single-photon detection simultaneously requires a nonlinear system front end, which will be obtained with the DEPFET active pixel technology foreseen for the advanced version of the camera. This technology will provide lower noise and a nonlinear response at the sensor level. This article describes the architecture of the whole detector system together with the main experimental results achieved up to now. © 1963-2012 IEEE.
  •  
2.
  • Shanbhag, S., et al. (författare)
  • Ectopic Bone Tissue Engineering in Mice Using Human Gingiva or Bone Marrow-Derived Stromal/Progenitor Cells in Scaffold-Hydrogel Constructs
  • 2021
  • Ingår i: Frontiers in Bioengineering and Biotechnology. - : Frontiers Media S.A.. - 2296-4185. ; 9
  • Tidskriftsartikel (refereegranskat)abstract
    • Three-dimensional (3D) spheroid culture can promote the osteogenic differentiation and bone regeneration capacity of mesenchymal stromal cells (MSC). Gingiva-derived progenitor cells (GPC) represent a less invasive alternative to bone marrow MSC (BMSC) for clinical applications. The aim of this study was to test the in vivo bone forming potential of human GPC and BMSC cultured as 3D spheroids or dissociated cells (2D). 2D and 3D cells encapsulated in constructs of human platelet lysate hydrogels (HPLG) and 3D-printed poly (L-lactide-co-trimethylene carbonate) scaffolds (HPLG-PLATMC) were implanted subcutaneously in nude mice; cell-free HPLG-PLATMC constructs served as a control. Mineralization was assessed using micro-computed tomography (µCT), histology, scanning electron microscopy (SEM) and in situ hybridization (ISH). After 4–8 weeks, µCT revealed greater mineralization in 3D-BMSC vs. 2D-BMSC and 3D-GPC (p < 0.05), and a similar trend in 2D-GPC vs. 2D-BMSC (p > 0.05). After 8 weeks, greater mineralization was observed in cell-free constructs vs. all 2D- and 3D-cell groups (p < 0.05). Histology and SEM revealed an irregular but similar mineralization pattern in all groups. ISH revealed similar numbers of 2D and 3D BMSC/GPC within and/or surrounding the mineralized areas. In summary, spheroid culture promoted ectopic mineralization in constructs of BMSC, while constructs of dissociated GPC and BMSC performed similarly. The combination of HPLG and PLATMC represents a promising scaffold for bone tissue engineering applications. 
  •  
3.
  • Bertl, Kristina, et al. (författare)
  • Morphometric characteristics of cortical and trabecular bone in atrophic edentulous mandibles
  • 2015
  • Ingår i: Clinical Oral Implants Research. - : John Wiley & Sons. - 0905-7161 .- 1600-0501. ; 26:7, s. 780-787
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: Adaptations of the alveolar ridge after tooth loss have been well described. However, studies on the morphometric characteristics of cortical bone are rare; hence, this study of human atrophic edentulous mandibles was undertaken. MATERIAL AND METHODS: Total cortical area, porosity, and thickness, and the percentage of cortical area in the complete mandibular area as well as in an area (height, 10 mm) starting at the most caudal point of the trabecular compartment and extending in the coronal direction were determined in 185 thin ground sections of edentulous mandibles (incisor region, 49; premolar region, 76; molar region, 60; 95 from females and 90 from males; mean age, 78.2 years, SD ± 7.8 years; Caucasian donors; cause of death: cardiovascular disease). Further, mandibular height and width and degree of residual ridge resorption (RRR) were recorded. RESULTS: The percentage of cortical area in the complete mandibular area increased with increasing RRR. Yet, evaluation of the 10-mm caudal portion corresponding to the basal part of the mandibular body did not confirm these changes in cortical bone. Cortical porosity and thickness decreased from the mesial to the distal region. Cortical porosity was unaffected by RRR, while cortical thickness increased, mainly at lingual aspects. CONCLUSIONS: In conclusion, cortical bone remained stable in different degrees of RRR except for some modulations in the lingual aspects. Changes in the relative composition between cortical and trabecular bone are due to loss of height and total area, mainly at expense of trabecular bone area, but not to adaptations of the cortical bone.
  •  
4.
  • Hansen, K., et al. (författare)
  • Qualification and Integration Aspects of the DSSC Mega-Pixel X-Ray Imager
  • 2019
  • Ingår i: IEEE Transactions on Nuclear Science. - : Institute of Electrical and Electronics Engineers Inc.. - 0018-9499 .- 1558-1578. ; 66:8, s. 1966-1975
  • Tidskriftsartikel (refereegranskat)abstract
    • The focal-plane module is the key component of the DEPFET sensor with signal compression (DSSC) mega-pixel X-ray imager and handles the data of 128 ×512 pixels. We report on assembly-related aspects, discuss the experimental investigation of bonding behavior of different adhesives, and present the metrology and electrical test results of the production. The module consists of two silicon (Si) sensors with flip-chip connected CMOS integrated circuits, a Si-heat spreader, a low-temperature co-fired ceramics circuit board, and a molybdenum frame. A low-modulus urethane-film adhesive fills the gaps between on-board components and frame. It is also used between board and heat spreader, reduces the misfit strain, and minimizes the module warpage very efficiently. The heat spreader reduces the on-board temperature gradient by about one order of magnitude. The placement precision of the bare modules to each other and the frame is characterized by a standard deviation below 10 and 65 μ m, respectively. The displacement due to the in-plane rotation and vertical tilting errors remains below 80 and 50 μm, respectively. The deflection of the sensor plane shows a mean value below 30 μm with a standard deviation below 15 μm. Less than 4% of the application-specified integrated circuits (ASICs) exhibit a malfunction. More than two-thirds of the sensors have a maximum leakage current below 1 μA. © 1963-2012 IEEE.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy