SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Themudo R) "

Sökning: WFRF:(Themudo R)

  • Resultat 1-10 av 10
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Saracco, A, et al. (författare)
  • Bolus compared with continuous infusion of microbubble contrast agent using real-time contrast harmonic imaging ultrasound in breast tumors
  • 2009
  • Ingår i: Acta radiologica (Stockholm, Sweden : 1987). - : SAGE Publications. - 1600-0455 .- 0284-1851. ; 50:8, s. 854-859
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Contrast-enhanced ultrasound (CEUS) has gained interest because of its ability to gather vascular information in various organs. There is still a matter of debate concerning its value in breast lesions. The method of choice on how to administer the contrast agent varies depending on the organ to be studied. Infusion of microbubbles is used in echocardiography, while bolus administration is the preferred technique for abdominal organs. Purpose: To compare—in equal doses—bolus versus continuous infusion of microbubbles, using real-time contrast harmonic imaging in breast tumors. Material and Methods: A total of 29 female patients (mean age 54 years) with either clear malignant or benign findings in the breast or axilla were included. Contrast harmonic imaging (CHI US) was performed with a Philips iU22 using an L9-3 MHz linear probe, especially designed for this purpose. A low mechanical index (0.06–0.07) was used to avoid massive destruction of the microbubbles. A dose of 2.4 ml of Sono Vue was first infused intravenously over 1 min with an infusion pump. After 10 min, the same dose was injected as a bolus over 2 s, followed by a flush of 10 ml of saline solution. Contrast uptakes by the tumors were recorded 2 min from the moment of injection, with both methods for each patient. Results: Bolus administration of contrast agent provided a sharply demarcated enhancement and wash-out pattern for all lesions. The continuous infusion of the same contrast agent failed to show any wash-in/wash-out or time-to-peak/peak intensity phenomena in all cases. Conclusion: CEUS using real-time harmonic imaging in order to evaluate breast tumors should be performed with bolus administration of contrast agent in order to achieve better intensity/time curve outcomes.
  •  
3.
  •  
4.
  •  
5.
  •  
6.
  • Lundin, M., et al. (författare)
  • Diffusely Increased Myocardial Extracellular Volume with or without Focal Late Gadolinium Enhancement: Prevalence and Associations with Left Ventricular Size and Function
  • 2022
  • Ingår i: Journal of Thoracic Imaging. - 0883-5993 .- 1536-0237. ; 37:1, s. 17-25
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Myocardial extracellular volume fraction (ECV) using cardiovascular magnetic resonance (CMR) can identify diffuse lesions not detected by late gadolinium enhancement (LGE). We aimed to determine the prevalence of increased ECV and its relation to other CMR findings. Materials and Methods: Consecutive patients (n=609, age median [interquartile range] 53 [39 to 66] y, 62% male) underwent CMR at 1.5 T. Focal lesions on LGE images were noted. ECV in regions without focal LGE findings defined diffuse changes. Pronounced increases in left ventricular (LV) end-diastolic volume index and LV mass index, and pronounced decreases in LV ejection fraction were defined as >3 SD from the sex-specific mean in healthy volunteers. Results: Of 609 patients without amyloidosis or hypertrophic cardiomyopathy, 8% had diffusely increased ECV and 5% of all patients had diffusely increased ECV without any focal LGE findings. Multivariate analysis showed that a pronounced increase in the LV end-diastolic volume index was associated with increased ECV (P=0.001), but not LGE (P=0.52). A pronounced decrease in LV ejection fraction was associated with the presence of LGE (P<0.001), but not with increased ECV (P=0.41). Conclusions: Eight percent of patients in this clinical cohort with known or suspected heart disease had diffusely increased ECV and 60% of these lacked focal LGE findings. LV size is independently associated with increased ECV, whereas systolic dysfunction is independently associated with LGE. This image-based clinical study demonstrates that ECV-CMR provides additional information negligibly related to the results of LGE imaging, and thereby increases the diagnostic yield of CMR. © 2020 Lippincott Williams and Wilkins. All rights reserved.
  •  
7.
  • Nickander, J, et al. (författare)
  • Females have higher myocardial perfusion, blood volume and extracellular volume compared to males - an adenosine stress cardiovascular magnetic resonance study
  • 2020
  • Ingår i: Scientific reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 10:1, s. 10380-
  • Tidskriftsartikel (refereegranskat)abstract
    • Knowledge on sex differences in myocardial perfusion, blood volume (MBV), and extracellular volume (ECV) in healthy individuals is scarce and conflicting. Therefore, this was investigated quantitatively by cardiovascular magnetic resonance (CMR). Healthy volunteers (n = 41, 51% female) underwent CMR at 1.5 T. Quantitative MBV [%] and perfusion [ml/min/g] maps were acquired during adenosine stress and at rest following an intravenous contrast bolus (0.05 mmol/kg, gadobutrol). Native T1 maps were acquired before and during adenosine stress, and after contrast (0.2 mmol/kg) at rest and during adenosine stress, rendering rest and stress ECV maps. Compared to males, females had higher perfusion, ECV, and MBV at stress, and perfusion and ECV at rest (p < 0.01 for all). Multivariate linear regression revealed that sex and MBV were associated with perfusion (sex beta −0.31, p = 0.03; MBV beta −0.37, p = 0.01, model R2 = 0.29, p < 0.01) while sex and hematocrit were associated with ECV (sex beta −0.33, p = 0.03; hematocrit beta −0.48, p < 0.01, model R2 = 0.54, p < 0.001). Myocardial perfusion, MBV, and ECV are higher in female healthy volunteers compared to males. Sex is an independent contributor to perfusion and ECV, beyond other physiological factors that differ between the sexes. These findings provide mechanistic insight into sex differences in myocardial physiology.
  •  
8.
  •  
9.
  • Svensson, A, et al. (författare)
  • Variable size of aortic subvalvular pseudoaneurysm
  • 2018
  • Ingår i: Acta radiologica open. - : SAGE Publications. - 2058-4601. ; 7:6, s. 2058460118778068-
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • Aortic subvalvular pseudoaneurysms (PSA) are particularly subjected to strain and shear stress forces from blood flow and therefore their size can vary along the heart cycle. Here we describe a case of an aortic subvalvular PSA that shows significant variation in size between systolic and diastolic phase during retrospective ECG-triggered cardiac computed tomography angiography.
  •  
10.
  • Themudo, R, et al. (författare)
  • Leaflet thickening and stent geometry in sutureless bioprosthetic aortic valves
  • 2020
  • Ingår i: Heart and vessels. - : Springer Science and Business Media LLC. - 1615-2573 .- 0910-8327. ; 35:6, s. 868-875
  • Tidskriftsartikel (refereegranskat)abstract
    • Underexpansion of transcatheter heart valves and the surgically implanted Perceval sutureless aortic valve bioprosthesis has been suggested as an underlying mechanism for hypo-attenuated leaflet thickening (HALT). This was a single-center prospective observational study that included 47 patients who underwent surgical aortic valve replacement with the Perceval sutureless bioprosthesis (LivaNova, London, United Kingdom) from 2012 to 2016 and were studied by four-dimensional cardiac computed tomography (CT). The association between overall and regional expansion and the prevalence of HALT was analyzed. In total 46 patients were included in the analysis. HALT was found in 39.1% of patients and the mean overall prosthesis expansion was 75.5 ± 5.2% (range 64.6–84.8%). Overall expansion did not differ between patients with HALT compared with patients without HALT (mean overall expansion 74.0 ± 5.2% vs. 76.5 ± 5.0%, P = 0.11). The prevalence of HALT was lower in patients with overall expansion > 80% compared to patients with expansion < 80% expansion though not significantly (20% vs. 44.4%, P = 0.16). None or trivial regional underexpansion was found in 94.7% of coronary cusps. There was no significant association between regional underexpansion and the prevalence of HALT (mean coronary cusp angle 120 ± 8° vs. 119 ± 10°, P = 0.53). The prevalence of HALT and overall underexpansion was high in the Perceval sutureless bioprosthetic valve. Overall underexpansion was not associated with HALT. Whether severe overall underexpansion increases the risk for HALT requires further study. Regional underexpansion was uncommon in the Perceval sutureless bioprosthetic valve and not associated with HALT.Clinical trial registration Unique identifier: NCT03753126 (http://www.clinicaltrials.gov).
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 10

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy