SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Tiberti Claudio) "

Sökning: WFRF:(Tiberti Claudio)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Falorni, Alberto, et al. (författare)
  • Determination of 21-hydroxylase autoantibodies: inter-laboratory concordance in the Euradrenal International Serum Exchange Program
  • 2015
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter GmbH. - 1434-6621 .- 1437-4331. ; 53:11, s. 1761-1770
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: 21-Hydroxylase autoantibodies (21OHAb) are markers of an adrenal autoimmune process that identifies individuals with autoimmune Addison's disease (AAD). Quality and inter-laboratory agreement of various 21OHAb tests are incompletely known. The objective of the study was to determine inter-laboratory concordance for 21OHAb determinations. Methods: Sixty-nine sera from 51 patients with AAD and 51 sera from 51 healthy subjects were blindly coded by a randomization center and distributed to 14 laboratories that determined 21OHAb, either by an "in-house" assay (n=9) using in vitro-translated S-35-21OH or luciferase-labeled 21OH or a commercial kit with I-125-21OH (n=5). Main outcome measures were diagnostic accuracy of each participating laboratory and inter-laboratory agreement of 21OHAb assays. Results: Intra-assay coefficient of variation ranged from 2.6% to 5.3% for laboratories using the commercial kit and from 5.1% to 23% for laboratories using "in-house" assays. Diagnostic accuracy, expressed as area under ROC curve (AUC), varied from 0.625 to 0.947 with the commercial kit and from 0.562 to 0.978 with "in-house" methods. Cohen's. of inter-rater agreement was 0.603 among all 14 laboratories, 0.691 among "in-house" laboratories, and 0.502 among commercial kit users. Optimized cutoff levels, calculated on the basis of AUCs, increased the diagnostic accuracy of every laboratory (AUC >0.9 for 11/14 laboratories) and increased the Cohen's. of inter-rater agreement. Discrepancies in quantitation of 21OHAb levels among different laboratories increased with increasing autoantibody levels. Conclusions: The quality of 21OHAb analytical procedures is mainly influenced by selection of cutoff value and correct handling of assay materials. A standardization program is needed to identify common standard sera and common measuring units.
  •  
2.
  • Li, Marcella, et al. (författare)
  • A Report on the International Transglutaminase Autoantibody Workshop for Celiac Disease
  • 2009
  • Ingår i: American Journal of Gastroenterology. - : Ovid Technologies (Wolters Kluwer Health). - 1572-0241 .- 0002-9270. ; 104:1, s. 154-163
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: Measurement of transglutaminase autoantibodies (TGAA) is considered to be the most efficient single serologic test for celiac disease (CD) by the American Gastroenterological Association Institute. We hypothesized that a large international collaborative effort toward improving and standardizing TGAA measurement is both feasible and necessary. The primary aim of this workshop is to compare TGAA assays among various research and clinical laboratories and examine assay concordance and improve (and eventually standardize) the TGAA assay. METHODS: A total of 20 laboratories (5 commercial laboratories, 15 research and clinical laboratories) participated that included enzyme-linked immunosorbent assay (ELISA) and radiobinding assays. A total of 150 serum samples were distributed to each laboratory, with each laboratory receiving an equal aliquot that was coded and blinded, composed of 100 healthy control sera and 50 CD sera. RESULTS: Laboratory sensitivity ranged from 69% to 93% and specificity ranged from 96% to 100%. By receiver operator characteristic analysis, the area under the curve (C index) ranged from 0.9488 to 0.9904. When analyzing for linear correlation, r-squared was as high as 0.8882 but as low as 0.4244 for the celiac samples between different laboratories performing ELISA. CONCLUSIONS: This transglutaminase autoantibody workshop allows for larger-scale international participation for the purposes of improving and eventually standardizing the TGAA assay with subsequent workshops.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy